diff --git a/drivers/net/phy/micrel.c b/drivers/net/phy/micrel.c
index de31c5170a5b..3db06b40580d 100644
--- a/drivers/net/phy/micrel.c
+++ b/drivers/net/phy/micrel.c
@@ -573,9 +573,40 @@ static int ksz9031_config_init(struct phy_device *phydev)
ksz9031_of_load_skew_values(phydev, of_node,
MII_KSZ9031RN_TX_DATA_PAD_SKEW, 4,
tx_data_skews, 4);
+
+ /* Silicon Errata Sheet (DS80000691D or DS80000692D):
+ * When the device links in the 1000BASE-T slave mode only,
+ * the optional 125MHz reference output clock (CLK125_NDO)
+ * has wide duty cycle variation.
+ *
+ * The optional CLK125_NDO clock does not meet the RGMII
+ * 45/55 percent (min/max) duty cycle requirement and therefore
+ * cannot be used directly by the MAC side for clocking
+ * applications that have setup/hold time requirements on
+ * rising and falling clock edges.
+ *
+ * Workaround:
+ * Force the phy to be the master to receive a stable clock
+ * which meets the duty cycle requirement.
+ */
+ if (of_property_read_bool(of_node, "micrel,force-master")) {
+ result = phy_read(phydev, MII_CTRL1000);
+ if (result < 0)
+ goto err_force_master;
+
+ /* enable master mode, config & prefer master */
+ result |= CTL1000_ENABLE_MASTER | CTL1000_AS_MASTER;
+ result = phy_write(phydev, MII_CTRL1000, result);
+ if (result < 0)
+ goto err_force_master;
+ }
}
return ksz9031_center_flp_timing(phydev);
+
+err_force_master:
+ phydev_err(phydev, "failed to force the phy to master mode\n");
+ return result;
}
#define KSZ8873MLL_GLOBAL_CONTROL_4 0x06