summaryrefslogtreecommitdiffstats
path: root/drivers/of/base.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/of/base.c')
-rw-r--r--drivers/of/base.c65
1 files changed, 46 insertions, 19 deletions
diff --git a/drivers/of/base.c b/drivers/of/base.c
index aace017fc452..f807d0edabf3 100644
--- a/drivers/of/base.c
+++ b/drivers/of/base.c
@@ -74,6 +74,13 @@ int of_n_size_cells(struct device_node *np)
}
EXPORT_SYMBOL(of_n_size_cells);
+#ifdef CONFIG_NUMA
+int __weak of_node_to_nid(struct device_node *np)
+{
+ return numa_node_id();
+}
+#endif
+
#if defined(CONFIG_OF_DYNAMIC)
/**
* of_node_get - Increment refcount of a node
@@ -265,9 +272,9 @@ static bool __of_find_n_match_cpu_property(struct device_node *cpun,
ac = of_n_addr_cells(cpun);
cell = of_get_property(cpun, prop_name, &prop_len);
- if (!cell)
+ if (!cell || !ac)
return false;
- prop_len /= sizeof(*cell);
+ prop_len /= sizeof(*cell) * ac;
for (tid = 0; tid < prop_len; tid++) {
hwid = of_read_number(cell, ac);
if (arch_match_cpu_phys_id(cpu, hwid)) {
@@ -280,6 +287,31 @@ static bool __of_find_n_match_cpu_property(struct device_node *cpun,
return false;
}
+/*
+ * arch_find_n_match_cpu_physical_id - See if the given device node is
+ * for the cpu corresponding to logical cpu 'cpu'. Return true if so,
+ * else false. If 'thread' is non-NULL, the local thread number within the
+ * core is returned in it.
+ */
+bool __weak arch_find_n_match_cpu_physical_id(struct device_node *cpun,
+ int cpu, unsigned int *thread)
+{
+ /* Check for non-standard "ibm,ppc-interrupt-server#s" property
+ * for thread ids on PowerPC. If it doesn't exist fallback to
+ * standard "reg" property.
+ */
+ if (IS_ENABLED(CONFIG_PPC) &&
+ __of_find_n_match_cpu_property(cpun,
+ "ibm,ppc-interrupt-server#s",
+ cpu, thread))
+ return true;
+
+ if (__of_find_n_match_cpu_property(cpun, "reg", cpu, thread))
+ return true;
+
+ return false;
+}
+
/**
* of_get_cpu_node - Get device node associated with the given logical CPU
*
@@ -300,24 +332,10 @@ static bool __of_find_n_match_cpu_property(struct device_node *cpun,
*/
struct device_node *of_get_cpu_node(int cpu, unsigned int *thread)
{
- struct device_node *cpun, *cpus;
-
- cpus = of_find_node_by_path("/cpus");
- if (!cpus)
- return NULL;
+ struct device_node *cpun;
- for_each_child_of_node(cpus, cpun) {
- if (of_node_cmp(cpun->type, "cpu"))
- continue;
- /* Check for non-standard "ibm,ppc-interrupt-server#s" property
- * for thread ids on PowerPC. If it doesn't exist fallback to
- * standard "reg" property.
- */
- if (IS_ENABLED(CONFIG_PPC) &&
- __of_find_n_match_cpu_property(cpun,
- "ibm,ppc-interrupt-server#s", cpu, thread))
- return cpun;
- if (__of_find_n_match_cpu_property(cpun, "reg", cpu, thread))
+ for_each_node_by_type(cpun, "cpu") {
+ if (arch_find_n_match_cpu_physical_id(cpun, cpu, thread))
return cpun;
}
return NULL;
@@ -1174,6 +1192,15 @@ int of_property_count_strings(struct device_node *np, const char *propname)
}
EXPORT_SYMBOL_GPL(of_property_count_strings);
+void of_print_phandle_args(const char *msg, const struct of_phandle_args *args)
+{
+ int i;
+ printk("%s %s", msg, of_node_full_name(args->np));
+ for (i = 0; i < args->args_count; i++)
+ printk(i ? ",%08x" : ":%08x", args->args[i]);
+ printk("\n");
+}
+
static int __of_parse_phandle_with_args(const struct device_node *np,
const char *list_name,
const char *cells_name,