diff options
Diffstat (limited to 'drivers/power/axp288_fuel_gauge.c')
-rw-r--r-- | drivers/power/axp288_fuel_gauge.c | 1154 |
1 files changed, 1154 insertions, 0 deletions
diff --git a/drivers/power/axp288_fuel_gauge.c b/drivers/power/axp288_fuel_gauge.c new file mode 100644 index 000000000000..ca1cc5a47eb1 --- /dev/null +++ b/drivers/power/axp288_fuel_gauge.c @@ -0,0 +1,1154 @@ +/* + * axp288_fuel_gauge.c - Xpower AXP288 PMIC Fuel Gauge Driver + * + * Copyright (C) 2014 Intel Corporation + * + * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + * + * This program is free software; you can redistribute it and/or modify + * it under the terms of the GNU General Public License as published by + * the Free Software Foundation; version 2 of the License. + * + * This program is distributed in the hope that it will be useful, but + * WITHOUT ANY WARRANTY; without even the implied warranty of + * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU + * General Public License for more details. + * + */ + +#include <linux/module.h> +#include <linux/kernel.h> +#include <linux/device.h> +#include <linux/regmap.h> +#include <linux/jiffies.h> +#include <linux/interrupt.h> +#include <linux/device.h> +#include <linux/workqueue.h> +#include <linux/mfd/axp20x.h> +#include <linux/platform_device.h> +#include <linux/power_supply.h> +#include <linux/iio/consumer.h> +#include <linux/debugfs.h> +#include <linux/seq_file.h> + +#define CHRG_STAT_BAT_SAFE_MODE (1 << 3) +#define CHRG_STAT_BAT_VALID (1 << 4) +#define CHRG_STAT_BAT_PRESENT (1 << 5) +#define CHRG_STAT_CHARGING (1 << 6) +#define CHRG_STAT_PMIC_OTP (1 << 7) + +#define CHRG_CCCV_CC_MASK 0xf /* 4 bits */ +#define CHRG_CCCV_CC_BIT_POS 0 +#define CHRG_CCCV_CC_OFFSET 200 /* 200mA */ +#define CHRG_CCCV_CC_LSB_RES 200 /* 200mA */ +#define CHRG_CCCV_ITERM_20P (1 << 4) /* 20% of CC */ +#define CHRG_CCCV_CV_MASK 0x60 /* 2 bits */ +#define CHRG_CCCV_CV_BIT_POS 5 +#define CHRG_CCCV_CV_4100MV 0x0 /* 4.10V */ +#define CHRG_CCCV_CV_4150MV 0x1 /* 4.15V */ +#define CHRG_CCCV_CV_4200MV 0x2 /* 4.20V */ +#define CHRG_CCCV_CV_4350MV 0x3 /* 4.35V */ +#define CHRG_CCCV_CHG_EN (1 << 7) + +#define CV_4100 4100 /* 4100mV */ +#define CV_4150 4150 /* 4150mV */ +#define CV_4200 4200 /* 4200mV */ +#define CV_4350 4350 /* 4350mV */ + +#define TEMP_IRQ_CFG_QWBTU (1 << 0) +#define TEMP_IRQ_CFG_WBTU (1 << 1) +#define TEMP_IRQ_CFG_QWBTO (1 << 2) +#define TEMP_IRQ_CFG_WBTO (1 << 3) +#define TEMP_IRQ_CFG_MASK 0xf + +#define FG_IRQ_CFG_LOWBATT_WL2 (1 << 0) +#define FG_IRQ_CFG_LOWBATT_WL1 (1 << 1) +#define FG_IRQ_CFG_LOWBATT_MASK 0x3 +#define LOWBAT_IRQ_STAT_LOWBATT_WL2 (1 << 0) +#define LOWBAT_IRQ_STAT_LOWBATT_WL1 (1 << 1) + +#define FG_CNTL_OCV_ADJ_STAT (1 << 2) +#define FG_CNTL_OCV_ADJ_EN (1 << 3) +#define FG_CNTL_CAP_ADJ_STAT (1 << 4) +#define FG_CNTL_CAP_ADJ_EN (1 << 5) +#define FG_CNTL_CC_EN (1 << 6) +#define FG_CNTL_GAUGE_EN (1 << 7) + +#define FG_REP_CAP_VALID (1 << 7) +#define FG_REP_CAP_VAL_MASK 0x7F + +#define FG_DES_CAP1_VALID (1 << 7) +#define FG_DES_CAP1_VAL_MASK 0x7F +#define FG_DES_CAP0_VAL_MASK 0xFF +#define FG_DES_CAP_RES_LSB 1456 /* 1.456mAhr */ + +#define FG_CC_MTR1_VALID (1 << 7) +#define FG_CC_MTR1_VAL_MASK 0x7F +#define FG_CC_MTR0_VAL_MASK 0xFF +#define FG_DES_CC_RES_LSB 1456 /* 1.456mAhr */ + +#define FG_OCV_CAP_VALID (1 << 7) +#define FG_OCV_CAP_VAL_MASK 0x7F +#define FG_CC_CAP_VALID (1 << 7) +#define FG_CC_CAP_VAL_MASK 0x7F + +#define FG_LOW_CAP_THR1_MASK 0xf0 /* 5% tp 20% */ +#define FG_LOW_CAP_THR1_VAL 0xa0 /* 15 perc */ +#define FG_LOW_CAP_THR2_MASK 0x0f /* 0% to 15% */ +#define FG_LOW_CAP_WARN_THR 14 /* 14 perc */ +#define FG_LOW_CAP_CRIT_THR 4 /* 4 perc */ +#define FG_LOW_CAP_SHDN_THR 0 /* 0 perc */ + +#define STATUS_MON_DELAY_JIFFIES (HZ * 60) /*60 sec */ +#define NR_RETRY_CNT 3 +#define DEV_NAME "axp288_fuel_gauge" + +/* 1.1mV per LSB expressed in uV */ +#define VOLTAGE_FROM_ADC(a) ((a * 11) / 10) +/* properties converted to tenths of degrees, uV, uA, uW */ +#define PROP_TEMP(a) ((a) * 10) +#define UNPROP_TEMP(a) ((a) / 10) +#define PROP_VOLT(a) ((a) * 1000) +#define PROP_CURR(a) ((a) * 1000) + +#define AXP288_FG_INTR_NUM 6 +enum { + QWBTU_IRQ = 0, + WBTU_IRQ, + QWBTO_IRQ, + WBTO_IRQ, + WL2_IRQ, + WL1_IRQ, +}; + +struct axp288_fg_info { + struct platform_device *pdev; + struct axp20x_fg_pdata *pdata; + struct regmap *regmap; + struct regmap_irq_chip_data *regmap_irqc; + int irq[AXP288_FG_INTR_NUM]; + struct power_supply *bat; + struct mutex lock; + int status; + struct delayed_work status_monitor; + struct dentry *debug_file; +}; + +static enum power_supply_property fuel_gauge_props[] = { + POWER_SUPPLY_PROP_STATUS, + POWER_SUPPLY_PROP_PRESENT, + POWER_SUPPLY_PROP_HEALTH, + POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN, + POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN, + POWER_SUPPLY_PROP_VOLTAGE_NOW, + POWER_SUPPLY_PROP_VOLTAGE_OCV, + POWER_SUPPLY_PROP_CURRENT_NOW, + POWER_SUPPLY_PROP_CAPACITY, + POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN, + POWER_SUPPLY_PROP_TEMP, + POWER_SUPPLY_PROP_TEMP_MAX, + POWER_SUPPLY_PROP_TEMP_MIN, + POWER_SUPPLY_PROP_TEMP_ALERT_MIN, + POWER_SUPPLY_PROP_TEMP_ALERT_MAX, + POWER_SUPPLY_PROP_TECHNOLOGY, + POWER_SUPPLY_PROP_CHARGE_FULL, + POWER_SUPPLY_PROP_CHARGE_NOW, + POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN, + POWER_SUPPLY_PROP_MODEL_NAME, +}; + +static int fuel_gauge_reg_readb(struct axp288_fg_info *info, int reg) +{ + int ret, i; + unsigned int val; + + for (i = 0; i < NR_RETRY_CNT; i++) { + ret = regmap_read(info->regmap, reg, &val); + if (ret == -EBUSY) + continue; + else + break; + } + + if (ret < 0) + dev_err(&info->pdev->dev, "axp288 reg read err:%d\n", ret); + + return val; +} + +static int fuel_gauge_reg_writeb(struct axp288_fg_info *info, int reg, u8 val) +{ + int ret; + + ret = regmap_write(info->regmap, reg, (unsigned int)val); + + if (ret < 0) + dev_err(&info->pdev->dev, "axp288 reg write err:%d\n", ret); + + return ret; +} + +static int pmic_read_adc_val(const char *name, int *raw_val, + struct axp288_fg_info *info) +{ + int ret, val = 0; + struct iio_channel *indio_chan; + + indio_chan = iio_channel_get(NULL, name); + if (IS_ERR_OR_NULL(indio_chan)) { + ret = PTR_ERR(indio_chan); + goto exit; + } + ret = iio_read_channel_raw(indio_chan, &val); + if (ret < 0) { + dev_err(&info->pdev->dev, + "IIO channel read error: %x, %x\n", ret, val); + goto err_exit; + } + + dev_dbg(&info->pdev->dev, "adc raw val=%x\n", val); + *raw_val = val; + +err_exit: + iio_channel_release(indio_chan); +exit: + return ret; +} + +#ifdef CONFIG_DEBUG_FS +static int fuel_gauge_debug_show(struct seq_file *s, void *data) +{ + struct axp288_fg_info *info = s->private; + int raw_val, ret; + + seq_printf(s, " PWR_STATUS[%02x] : %02x\n", + AXP20X_PWR_INPUT_STATUS, + fuel_gauge_reg_readb(info, AXP20X_PWR_INPUT_STATUS)); + seq_printf(s, "PWR_OP_MODE[%02x] : %02x\n", + AXP20X_PWR_OP_MODE, + fuel_gauge_reg_readb(info, AXP20X_PWR_OP_MODE)); + seq_printf(s, " CHRG_CTRL1[%02x] : %02x\n", + AXP20X_CHRG_CTRL1, + fuel_gauge_reg_readb(info, AXP20X_CHRG_CTRL1)); + seq_printf(s, " VLTF[%02x] : %02x\n", + AXP20X_V_LTF_DISCHRG, + fuel_gauge_reg_readb(info, AXP20X_V_LTF_DISCHRG)); + seq_printf(s, " VHTF[%02x] : %02x\n", + AXP20X_V_HTF_DISCHRG, + fuel_gauge_reg_readb(info, AXP20X_V_HTF_DISCHRG)); + seq_printf(s, " CC_CTRL[%02x] : %02x\n", + AXP20X_CC_CTRL, + fuel_gauge_reg_readb(info, AXP20X_CC_CTRL)); + seq_printf(s, "BATTERY CAP[%02x] : %02x\n", + AXP20X_FG_RES, + fuel_gauge_reg_readb(info, AXP20X_FG_RES)); + seq_printf(s, " FG_RDC1[%02x] : %02x\n", + AXP288_FG_RDC1_REG, + fuel_gauge_reg_readb(info, AXP288_FG_RDC1_REG)); + seq_printf(s, " FG_RDC0[%02x] : %02x\n", + AXP288_FG_RDC0_REG, + fuel_gauge_reg_readb(info, AXP288_FG_RDC0_REG)); + seq_printf(s, " FG_OCVH[%02x] : %02x\n", + AXP288_FG_OCVH_REG, + fuel_gauge_reg_readb(info, AXP288_FG_OCVH_REG)); + seq_printf(s, " FG_OCVL[%02x] : %02x\n", + AXP288_FG_OCVL_REG, + fuel_gauge_reg_readb(info, AXP288_FG_OCVL_REG)); + seq_printf(s, "FG_DES_CAP1[%02x] : %02x\n", + AXP288_FG_DES_CAP1_REG, + fuel_gauge_reg_readb(info, AXP288_FG_DES_CAP1_REG)); + seq_printf(s, "FG_DES_CAP0[%02x] : %02x\n", + AXP288_FG_DES_CAP0_REG, + fuel_gauge_reg_readb(info, AXP288_FG_DES_CAP0_REG)); + seq_printf(s, " FG_CC_MTR1[%02x] : %02x\n", + AXP288_FG_CC_MTR1_REG, + fuel_gauge_reg_readb(info, AXP288_FG_CC_MTR1_REG)); + seq_printf(s, " FG_CC_MTR0[%02x] : %02x\n", + AXP288_FG_CC_MTR0_REG, + fuel_gauge_reg_readb(info, AXP288_FG_CC_MTR0_REG)); + seq_printf(s, " FG_OCV_CAP[%02x] : %02x\n", + AXP288_FG_OCV_CAP_REG, + fuel_gauge_reg_readb(info, AXP288_FG_OCV_CAP_REG)); + seq_printf(s, " FG_CC_CAP[%02x] : %02x\n", + AXP288_FG_CC_CAP_REG, + fuel_gauge_reg_readb(info, AXP288_FG_CC_CAP_REG)); + seq_printf(s, " FG_LOW_CAP[%02x] : %02x\n", + AXP288_FG_LOW_CAP_REG, + fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG)); + seq_printf(s, "TUNING_CTL0[%02x] : %02x\n", + AXP288_FG_TUNE0, + fuel_gauge_reg_readb(info, AXP288_FG_TUNE0)); + seq_printf(s, "TUNING_CTL1[%02x] : %02x\n", + AXP288_FG_TUNE1, + fuel_gauge_reg_readb(info, AXP288_FG_TUNE1)); + seq_printf(s, "TUNING_CTL2[%02x] : %02x\n", + AXP288_FG_TUNE2, + fuel_gauge_reg_readb(info, AXP288_FG_TUNE2)); + seq_printf(s, "TUNING_CTL3[%02x] : %02x\n", + AXP288_FG_TUNE3, + fuel_gauge_reg_readb(info, AXP288_FG_TUNE3)); + seq_printf(s, "TUNING_CTL4[%02x] : %02x\n", + AXP288_FG_TUNE4, + fuel_gauge_reg_readb(info, AXP288_FG_TUNE4)); + seq_printf(s, "TUNING_CTL5[%02x] : %02x\n", + AXP288_FG_TUNE5, + fuel_gauge_reg_readb(info, AXP288_FG_TUNE5)); + + ret = pmic_read_adc_val("axp288-batt-temp", &raw_val, info); + if (ret >= 0) + seq_printf(s, "axp288-batttemp : %d\n", raw_val); + ret = pmic_read_adc_val("axp288-pmic-temp", &raw_val, info); + if (ret >= 0) + seq_printf(s, "axp288-pmictemp : %d\n", raw_val); + ret = pmic_read_adc_val("axp288-system-temp", &raw_val, info); + if (ret >= 0) + seq_printf(s, "axp288-systtemp : %d\n", raw_val); + ret = pmic_read_adc_val("axp288-chrg-curr", &raw_val, info); + if (ret >= 0) + seq_printf(s, "axp288-chrgcurr : %d\n", raw_val); + ret = pmic_read_adc_val("axp288-chrg-d-curr", &raw_val, info); + if (ret >= 0) + seq_printf(s, "axp288-dchrgcur : %d\n", raw_val); + ret = pmic_read_adc_val("axp288-batt-volt", &raw_val, info); + if (ret >= 0) + seq_printf(s, "axp288-battvolt : %d\n", raw_val); + + return 0; +} + +static int debug_open(struct inode *inode, struct file *file) +{ + return single_open(file, fuel_gauge_debug_show, inode->i_private); +} + +static const struct file_operations fg_debug_fops = { + .open = debug_open, + .read = seq_read, + .llseek = seq_lseek, + .release = single_release, +}; + +static void fuel_gauge_create_debugfs(struct axp288_fg_info *info) +{ + info->debug_file = debugfs_create_file("fuelgauge", 0666, NULL, + info, &fg_debug_fops); +} + +static void fuel_gauge_remove_debugfs(struct axp288_fg_info *info) +{ + debugfs_remove(info->debug_file); +} +#else +static inline void fuel_gauge_create_debugfs(struct axp288_fg_info *info) +{ +} +static inline void fuel_gauge_remove_debugfs(struct axp288_fg_info *info) +{ +} +#endif + +static void fuel_gauge_get_status(struct axp288_fg_info *info) +{ + int pwr_stat, ret; + int charge, discharge; + + pwr_stat = fuel_gauge_reg_readb(info, AXP20X_PWR_INPUT_STATUS); + if (pwr_stat < 0) { + dev_err(&info->pdev->dev, + "PWR STAT read failed:%d\n", pwr_stat); + return; + } + ret = pmic_read_adc_val("axp288-chrg-curr", &charge, info); + if (ret < 0) { + dev_err(&info->pdev->dev, + "ADC charge current read failed:%d\n", ret); + return; + } + ret = pmic_read_adc_val("axp288-chrg-d-curr", &discharge, info); + if (ret < 0) { + dev_err(&info->pdev->dev, + "ADC discharge current read failed:%d\n", ret); + return; + } + + if (charge > 0) + info->status = POWER_SUPPLY_STATUS_CHARGING; + else if (discharge > 0) + info->status = POWER_SUPPLY_STATUS_DISCHARGING; + else { + if (pwr_stat & CHRG_STAT_BAT_PRESENT) + info->status = POWER_SUPPLY_STATUS_FULL; + else + info->status = POWER_SUPPLY_STATUS_NOT_CHARGING; + } +} + +static int fuel_gauge_get_vbatt(struct axp288_fg_info *info, int *vbatt) +{ + int ret = 0, raw_val; + + ret = pmic_read_adc_val("axp288-batt-volt", &raw_val, info); + if (ret < 0) + goto vbatt_read_fail; + + *vbatt = VOLTAGE_FROM_ADC(raw_val); +vbatt_read_fail: + return ret; +} + +static int fuel_gauge_get_current(struct axp288_fg_info *info, int *cur) +{ + int ret, value = 0; + int charge, discharge; + + ret = pmic_read_adc_val("axp288-chrg-curr", &charge, info); + if (ret < 0) + goto current_read_fail; + ret = pmic_read_adc_val("axp288-chrg-d-curr", &discharge, info); + if (ret < 0) + goto current_read_fail; + + if (charge > 0) + value = charge; + else if (discharge > 0) + value = -1 * discharge; + + *cur = value; +current_read_fail: + return ret; +} + +static int temp_to_adc(struct axp288_fg_info *info, int tval) +{ + int rntc = 0, i, ret, adc_val; + int rmin, rmax, tmin, tmax; + int tcsz = info->pdata->tcsz; + + /* get the Rntc resitance value for this temp */ + if (tval > info->pdata->thermistor_curve[0][1]) { + rntc = info->pdata->thermistor_curve[0][0]; + } else if (tval <= info->pdata->thermistor_curve[tcsz-1][1]) { + rntc = info->pdata->thermistor_curve[tcsz-1][0]; + } else { + for (i = 1; i < tcsz; i++) { + if (tval > info->pdata->thermistor_curve[i][1]) { + rmin = info->pdata->thermistor_curve[i-1][0]; + rmax = info->pdata->thermistor_curve[i][0]; + tmin = info->pdata->thermistor_curve[i-1][1]; + tmax = info->pdata->thermistor_curve[i][1]; + rntc = rmin + ((rmax - rmin) * + (tval - tmin) / (tmax - tmin)); + break; + } + } + } + + /* we need the current to calculate the proper adc voltage */ + ret = fuel_gauge_reg_readb(info, AXP20X_ADC_RATE); + if (ret < 0) { + dev_err(&info->pdev->dev, "%s:read err:%d\n", __func__, ret); + ret = 0x30; + } + + /* + * temperature is proportional to NTS thermistor resistance + * ADC_RATE[5-4] determines current, 00=20uA,01=40uA,10=60uA,11=80uA + * [12-bit ADC VAL] = R_NTC(Ω) * current / 800 + */ + adc_val = rntc * (20 + (20 * ((ret >> 4) & 0x3))) / 800; + + return adc_val; +} + +static int adc_to_temp(struct axp288_fg_info *info, int adc_val) +{ + int ret, r, i, tval = 0; + int rmin, rmax, tmin, tmax; + int tcsz = info->pdata->tcsz; + + ret = fuel_gauge_reg_readb(info, AXP20X_ADC_RATE); + if (ret < 0) { + dev_err(&info->pdev->dev, "%s:read err:%d\n", __func__, ret); + ret = 0x30; + } + + /* + * temperature is proportional to NTS thermistor resistance + * ADC_RATE[5-4] determines current, 00=20uA,01=40uA,10=60uA,11=80uA + * R_NTC(Ω) = [12-bit ADC VAL] * 800 / current + */ + r = adc_val * 800 / (20 + (20 * ((ret >> 4) & 0x3))); + + if (r < info->pdata->thermistor_curve[0][0]) { + tval = info->pdata->thermistor_curve[0][1]; + } else if (r >= info->pdata->thermistor_curve[tcsz-1][0]) { + tval = info->pdata->thermistor_curve[tcsz-1][1]; + } else { + for (i = 1; i < tcsz; i++) { + if (r < info->pdata->thermistor_curve[i][0]) { + rmin = info->pdata->thermistor_curve[i-1][0]; + rmax = info->pdata->thermistor_curve[i][0]; + tmin = info->pdata->thermistor_curve[i-1][1]; + tmax = info->pdata->thermistor_curve[i][1]; + tval = tmin + ((tmax - tmin) * + (r - rmin) / (rmax - rmin)); + break; + } + } + } + + return tval; +} + +static int fuel_gauge_get_btemp(struct axp288_fg_info *info, int *btemp) +{ + int ret, raw_val = 0; + + ret = pmic_read_adc_val("axp288-batt-temp", &raw_val, info); + if (ret < 0) + goto temp_read_fail; + + *btemp = adc_to_temp(info, raw_val); + +temp_read_fail: + return ret; +} + +static int fuel_gauge_get_vocv(struct axp288_fg_info *info, int *vocv) +{ + int ret, value; + + /* 12-bit data value, upper 8 in OCVH, lower 4 in OCVL */ + ret = fuel_gauge_reg_readb(info, AXP288_FG_OCVH_REG); + if (ret < 0) + goto vocv_read_fail; + value = ret << 4; + + ret = fuel_gauge_reg_readb(info, AXP288_FG_OCVL_REG); + if (ret < 0) + goto vocv_read_fail; + value |= (ret & 0xf); + + *vocv = VOLTAGE_FROM_ADC(value); +vocv_read_fail: + return ret; +} + +static int fuel_gauge_battery_health(struct axp288_fg_info *info) +{ + int temp, vocv; + int ret, health = POWER_SUPPLY_HEALTH_UNKNOWN; + + ret = fuel_gauge_get_btemp(info, &temp); + if (ret < 0) + goto health_read_fail; + + ret = fuel_gauge_get_vocv(info, &vocv); + if (ret < 0) + goto health_read_fail; + + if (vocv > info->pdata->max_volt) + health = POWER_SUPPLY_HEALTH_OVERVOLTAGE; + else if (temp > info->pdata->max_temp) + health = POWER_SUPPLY_HEALTH_OVERHEAT; + else if (temp < info->pdata->min_temp) + health = POWER_SUPPLY_HEALTH_COLD; + else if (vocv < info->pdata->min_volt) + health = POWER_SUPPLY_HEALTH_DEAD; + else + health = POWER_SUPPLY_HEALTH_GOOD; + +health_read_fail: + return health; +} + +static int fuel_gauge_set_high_btemp_alert(struct axp288_fg_info *info) +{ + int ret, adc_val; + + /* program temperature threshold as 1/16 ADC value */ + adc_val = temp_to_adc(info, info->pdata->max_temp); + ret = fuel_gauge_reg_writeb(info, AXP20X_V_HTF_DISCHRG, adc_val >> 4); + + return ret; +} + +static int fuel_gauge_set_low_btemp_alert(struct axp288_fg_info *info) +{ + int ret, adc_val; + + /* program temperature threshold as 1/16 ADC value */ + adc_val = temp_to_adc(info, info->pdata->min_temp); + ret = fuel_gauge_reg_writeb(info, AXP20X_V_LTF_DISCHRG, adc_val >> 4); + + return ret; +} + +static int fuel_gauge_get_property(struct power_supply *ps, + enum power_supply_property prop, + union power_supply_propval *val) +{ + struct axp288_fg_info *info = power_supply_get_drvdata(ps); + int ret = 0, value; + + mutex_lock(&info->lock); + switch (prop) { + case POWER_SUPPLY_PROP_STATUS: + fuel_gauge_get_status(info); + val->intval = info->status; + break; + case POWER_SUPPLY_PROP_HEALTH: + val->intval = fuel_gauge_battery_health(info); + break; + case POWER_SUPPLY_PROP_VOLTAGE_NOW: + ret = fuel_gauge_get_vbatt(info, &value); + if (ret < 0) + goto fuel_gauge_read_err; + val->intval = PROP_VOLT(value); + break; + case POWER_SUPPLY_PROP_VOLTAGE_OCV: + ret = fuel_gauge_get_vocv(info, &value); + if (ret < 0) + goto fuel_gauge_read_err; + val->intval = PROP_VOLT(value); + break; + case POWER_SUPPLY_PROP_CURRENT_NOW: + ret = fuel_gauge_get_current(info, &value); + if (ret < 0) + goto fuel_gauge_read_err; + val->intval = PROP_CURR(value); + break; + case POWER_SUPPLY_PROP_PRESENT: + ret = fuel_gauge_reg_readb(info, AXP20X_PWR_OP_MODE); + if (ret < 0) + goto fuel_gauge_read_err; + + if (ret & CHRG_STAT_BAT_PRESENT) + val->intval = 1; + else + val->intval = 0; + break; + case POWER_SUPPLY_PROP_CAPACITY: + ret = fuel_gauge_reg_readb(info, AXP20X_FG_RES); + if (ret < 0) + goto fuel_gauge_read_err; + + if (!(ret & FG_REP_CAP_VALID)) + dev_err(&info->pdev->dev, + "capacity measurement not valid\n"); + val->intval = (ret & FG_REP_CAP_VAL_MASK); + break; + case POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN: + ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG); + if (ret < 0) + goto fuel_gauge_read_err; + val->intval = (ret & 0x0f); + break; + case POWER_SUPPLY_PROP_TEMP: + ret = fuel_gauge_get_btemp(info, &value); + if (ret < 0) + goto fuel_gauge_read_err; + val->intval = PROP_TEMP(value); + break; + case POWER_SUPPLY_PROP_TEMP_MAX: + case POWER_SUPPLY_PROP_TEMP_ALERT_MAX: + val->intval = PROP_TEMP(info->pdata->max_temp); + break; + case POWER_SUPPLY_PROP_TEMP_MIN: + case POWER_SUPPLY_PROP_TEMP_ALERT_MIN: + val->intval = PROP_TEMP(info->pdata->min_temp); + break; + case POWER_SUPPLY_PROP_TECHNOLOGY: + val->intval = POWER_SUPPLY_TECHNOLOGY_LION; + break; + case POWER_SUPPLY_PROP_CHARGE_NOW: + ret = fuel_gauge_reg_readb(info, AXP288_FG_CC_MTR1_REG); + if (ret < 0) + goto fuel_gauge_read_err; + + value = (ret & FG_CC_MTR1_VAL_MASK) << 8; + ret = fuel_gauge_reg_readb(info, AXP288_FG_CC_MTR0_REG); + if (ret < 0) + goto fuel_gauge_read_err; + value |= (ret & FG_CC_MTR0_VAL_MASK); + val->intval = value * FG_DES_CAP_RES_LSB; + break; + case POWER_SUPPLY_PROP_CHARGE_FULL: + ret = fuel_gauge_reg_readb(info, AXP288_FG_DES_CAP1_REG); + if (ret < 0) + goto fuel_gauge_read_err; + + value = (ret & FG_DES_CAP1_VAL_MASK) << 8; + ret = fuel_gauge_reg_readb(info, AXP288_FG_DES_CAP0_REG); + if (ret < 0) + goto fuel_gauge_read_err; + value |= (ret & FG_DES_CAP0_VAL_MASK); + val->intval = value * FG_DES_CAP_RES_LSB; + break; + case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN: + val->intval = PROP_CURR(info->pdata->design_cap); + break; + case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN: + val->intval = PROP_VOLT(info->pdata->max_volt); + break; + case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN: + val->intval = PROP_VOLT(info->pdata->min_volt); + break; + case POWER_SUPPLY_PROP_MODEL_NAME: + val->strval = info->pdata->battid; + break; + default: + mutex_unlock(&info->lock); + return -EINVAL; + } + + mutex_unlock(&info->lock); + return 0; + +fuel_gauge_read_err: + mutex_unlock(&info->lock); + return ret; +} + +static int fuel_gauge_set_property(struct power_supply *ps, + enum power_supply_property prop, + const union power_supply_propval *val) +{ + struct axp288_fg_info *info = power_supply_get_drvdata(ps); + int ret = 0; + + mutex_lock(&info->lock); + switch (prop) { + case POWER_SUPPLY_PROP_STATUS: + info->status = val->intval; + break; + case POWER_SUPPLY_PROP_TEMP_MIN: + case POWER_SUPPLY_PROP_TEMP_ALERT_MIN: + if ((val->intval < PD_DEF_MIN_TEMP) || + (val->intval > PD_DEF_MAX_TEMP)) { + ret = -EINVAL; + break; + } + info->pdata->min_temp = UNPROP_TEMP(val->intval); + ret = fuel_gauge_set_low_btemp_alert(info); + if (ret < 0) + dev_err(&info->pdev->dev, + "temp alert min set fail:%d\n", ret); + break; + case POWER_SUPPLY_PROP_TEMP_MAX: + case POWER_SUPPLY_PROP_TEMP_ALERT_MAX: + if ((val->intval < PD_DEF_MIN_TEMP) || + (val->intval > PD_DEF_MAX_TEMP)) { + ret = -EINVAL; + break; + } + info->pdata->max_temp = UNPROP_TEMP(val->intval); + ret = fuel_gauge_set_high_btemp_alert(info); + if (ret < 0) + dev_err(&info->pdev->dev, + "temp alert max set fail:%d\n", ret); + break; + case POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN: + if ((val->intval < 0) || (val->intval > 15)) { + ret = -EINVAL; + break; + } + ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG); + if (ret < 0) + break; + ret &= 0xf0; + ret |= (val->intval & 0xf); + ret = fuel_gauge_reg_writeb(info, AXP288_FG_LOW_CAP_REG, ret); + break; + default: + ret = -EINVAL; + break; + } + + mutex_unlock(&info->lock); + return ret; +} + +static int fuel_gauge_property_is_writeable(struct power_supply *psy, + enum power_supply_property psp) +{ + int ret; + + switch (psp) { + case POWER_SUPPLY_PROP_STATUS: + case POWER_SUPPLY_PROP_TEMP_MIN: + case POWER_SUPPLY_PROP_TEMP_ALERT_MIN: + case POWER_SUPPLY_PROP_TEMP_MAX: + case POWER_SUPPLY_PROP_TEMP_ALERT_MAX: + case POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN: + ret = 1; + break; + default: + ret = 0; + } + + return ret; +} + +static void fuel_gauge_status_monitor(struct work_struct *work) +{ + struct axp288_fg_info *info = container_of(work, + struct axp288_fg_info, status_monitor.work); + + fuel_gauge_get_status(info); + power_supply_changed(info->bat); + schedule_delayed_work(&info->status_monitor, STATUS_MON_DELAY_JIFFIES); +} + +static irqreturn_t fuel_gauge_thread_handler(int irq, void *dev) +{ + struct axp288_fg_info *info = dev; + int i; + + for (i = 0; i < AXP288_FG_INTR_NUM; i++) { + if (info->irq[i] == irq) + break; + } + + if (i >= AXP288_FG_INTR_NUM) { + dev_warn(&info->pdev->dev, "spurious interrupt!!\n"); + return IRQ_NONE; + } + + switch (i) { + case QWBTU_IRQ: + dev_info(&info->pdev->dev, + "Quit Battery under temperature in work mode IRQ (QWBTU)\n"); + break; + case WBTU_IRQ: + dev_info(&info->pdev->dev, + "Battery under temperature in work mode IRQ (WBTU)\n"); + break; + case QWBTO_IRQ: + dev_info(&info->pdev->dev, + "Quit Battery over temperature in work mode IRQ (QWBTO)\n"); + break; + case WBTO_IRQ: + dev_info(&info->pdev->dev, + "Battery over temperature in work mode IRQ (WBTO)\n"); + break; + case WL2_IRQ: + dev_info(&info->pdev->dev, "Low Batt Warning(2) INTR\n"); + break; + case WL1_IRQ: + dev_info(&info->pdev->dev, "Low Batt Warning(1) INTR\n"); + break; + default: + dev_warn(&info->pdev->dev, "Spurious Interrupt!!!\n"); + } + + power_supply_changed(info->bat); + return IRQ_HANDLED; +} + +static void fuel_gauge_external_power_changed(struct power_supply *psy) +{ + struct axp288_fg_info *info = power_supply_get_drvdata(psy); + + power_supply_changed(info->bat); +} + +static const struct power_supply_desc fuel_gauge_desc = { + .name = DEV_NAME, + .type = POWER_SUPPLY_TYPE_BATTERY, + .properties = fuel_gauge_props, + .num_properties = ARRAY_SIZE(fuel_gauge_props), + .get_property = fuel_gauge_get_property, + .set_property = fuel_gauge_set_property, + .property_is_writeable = fuel_gauge_property_is_writeable, + .external_power_changed = fuel_gauge_external_power_changed, +}; + +static int fuel_gauge_set_lowbatt_thresholds(struct axp288_fg_info *info) +{ + int ret; + u8 reg_val; + + ret = fuel_gauge_reg_readb(info, AXP20X_FG_RES); + if (ret < 0) { + dev_err(&info->pdev->dev, "%s:read err:%d\n", __func__, ret); + return ret; + } + ret = (ret & FG_REP_CAP_VAL_MASK); + + if (ret > FG_LOW_CAP_WARN_THR) + reg_val = FG_LOW_CAP_WARN_THR; + else if (ret > FG_LOW_CAP_CRIT_THR) + reg_val = FG_LOW_CAP_CRIT_THR; + else + reg_val = FG_LOW_CAP_SHDN_THR; + + reg_val |= FG_LOW_CAP_THR1_VAL; + ret = fuel_gauge_reg_writeb(info, AXP288_FG_LOW_CAP_REG, reg_val); + if (ret < 0) + dev_err(&info->pdev->dev, "%s:write err:%d\n", __func__, ret); + + return ret; +} + +static int fuel_gauge_program_vbatt_full(struct axp288_fg_info *info) +{ + int ret; + u8 val; + + ret = fuel_gauge_reg_readb(info, AXP20X_CHRG_CTRL1); + if (ret < 0) + goto fg_prog_ocv_fail; + else + val = (ret & ~CHRG_CCCV_CV_MASK); + + switch (info->pdata->max_volt) { + case CV_4100: + val |= (CHRG_CCCV_CV_4100MV << CHRG_CCCV_CV_BIT_POS); + break; + case CV_4150: + val |= (CHRG_CCCV_CV_4150MV << CHRG_CCCV_CV_BIT_POS); + break; + case CV_4200: + val |= (CHRG_CCCV_CV_4200MV << CHRG_CCCV_CV_BIT_POS); + break; + case CV_4350: + val |= (CHRG_CCCV_CV_4350MV << CHRG_CCCV_CV_BIT_POS); + break; + default: + val |= (CHRG_CCCV_CV_4200MV << CHRG_CCCV_CV_BIT_POS); + break; + } + + ret = fuel_gauge_reg_writeb(info, AXP20X_CHRG_CTRL1, val); +fg_prog_ocv_fail: + return ret; +} + +static int fuel_gauge_program_design_cap(struct axp288_fg_info *info) +{ + int ret; + + ret = fuel_gauge_reg_writeb(info, + AXP288_FG_DES_CAP1_REG, info->pdata->cap1); + if (ret < 0) + goto fg_prog_descap_fail; + + ret = fuel_gauge_reg_writeb(info, + AXP288_FG_DES_CAP0_REG, info->pdata->cap0); + +fg_prog_descap_fail: + return ret; +} + +static int fuel_gauge_program_ocv_curve(struct axp288_fg_info *info) +{ + int ret = 0, i; + + for (i = 0; i < OCV_CURVE_SIZE; i++) { + ret = fuel_gauge_reg_writeb(info, + AXP288_FG_OCV_CURVE_REG + i, info->pdata->ocv_curve[i]); + if (ret < 0) + goto fg_prog_ocv_fail; + } + +fg_prog_ocv_fail: + return ret; +} + +static int fuel_gauge_program_rdc_vals(struct axp288_fg_info *info) +{ + int ret; + + ret = fuel_gauge_reg_writeb(info, + AXP288_FG_RDC1_REG, info->pdata->rdc1); + if (ret < 0) + goto fg_prog_ocv_fail; + + ret = fuel_gauge_reg_writeb(info, + AXP288_FG_RDC0_REG, info->pdata->rdc0); + +fg_prog_ocv_fail: + return ret; +} + +static void fuel_gauge_init_config_regs(struct axp288_fg_info *info) +{ + int ret; + + /* + * check if the config data is already + * programmed and if so just return. + */ + + ret = fuel_gauge_reg_readb(info, AXP288_FG_DES_CAP1_REG); + if (ret < 0) { + dev_warn(&info->pdev->dev, "CAP1 reg read err!!\n"); + } else if (!(ret & FG_DES_CAP1_VALID)) { + dev_info(&info->pdev->dev, "FG data needs to be initialized\n"); + } else { + dev_info(&info->pdev->dev, "FG data is already initialized\n"); + return; + } + + ret = fuel_gauge_program_vbatt_full(info); + if (ret < 0) + dev_err(&info->pdev->dev, "set vbatt full fail:%d\n", ret); + + ret = fuel_gauge_program_design_cap(info); + if (ret < 0) + dev_err(&info->pdev->dev, "set design cap fail:%d\n", ret); + + ret = fuel_gauge_program_rdc_vals(info); + if (ret < 0) + dev_err(&info->pdev->dev, "set rdc fail:%d\n", ret); + + ret = fuel_gauge_program_ocv_curve(info); + if (ret < 0) + dev_err(&info->pdev->dev, "set ocv curve fail:%d\n", ret); + + ret = fuel_gauge_set_lowbatt_thresholds(info); + if (ret < 0) + dev_err(&info->pdev->dev, "lowbatt thr set fail:%d\n", ret); + + ret = fuel_gauge_reg_writeb(info, AXP20X_CC_CTRL, 0xef); + if (ret < 0) + dev_err(&info->pdev->dev, "gauge cntl set fail:%d\n", ret); +} + +static void fuel_gauge_init_irq(struct axp288_fg_info *info) +{ + int ret, i, pirq; + + for (i = 0; i < AXP288_FG_INTR_NUM; i++) { + pirq = platform_get_irq(info->pdev, i); + info->irq[i] = regmap_irq_get_virq(info->regmap_irqc, pirq); + if (info->irq[i] < 0) { + dev_warn(&info->pdev->dev, + "regmap_irq get virq failed for IRQ %d: %d\n", + pirq, info->irq[i]); + info->irq[i] = -1; + goto intr_failed; + } + ret = request_threaded_irq(info->irq[i], + NULL, fuel_gauge_thread_handler, + IRQF_ONESHOT, DEV_NAME, info); + if (ret) { + dev_warn(&info->pdev->dev, + "request irq failed for IRQ %d: %d\n", + pirq, info->irq[i]); + info->irq[i] = -1; + goto intr_failed; + } else { + dev_info(&info->pdev->dev, "HW IRQ %d -> VIRQ %d\n", + pirq, info->irq[i]); + } + } + return; + +intr_failed: + for (; i > 0; i--) { + free_irq(info->irq[i - 1], info); + info->irq[i - 1] = -1; + } +} + +static void fuel_gauge_init_hw_regs(struct axp288_fg_info *info) +{ + int ret; + unsigned int val; + + ret = fuel_gauge_set_high_btemp_alert(info); + if (ret < 0) + dev_err(&info->pdev->dev, "high batt temp set fail:%d\n", ret); + + ret = fuel_gauge_set_low_btemp_alert(info); + if (ret < 0) + dev_err(&info->pdev->dev, "low batt temp set fail:%d\n", ret); + + /* enable interrupts */ + val = fuel_gauge_reg_readb(info, AXP20X_IRQ3_EN); + val |= TEMP_IRQ_CFG_MASK; + fuel_gauge_reg_writeb(info, AXP20X_IRQ3_EN, val); + + val = fuel_gauge_reg_readb(info, AXP20X_IRQ4_EN); + val |= FG_IRQ_CFG_LOWBATT_MASK; + val = fuel_gauge_reg_writeb(info, AXP20X_IRQ4_EN, val); +} + +static int axp288_fuel_gauge_probe(struct platform_device *pdev) +{ + int ret = 0; + struct axp288_fg_info *info; + struct axp20x_dev *axp20x = dev_get_drvdata(pdev->dev.parent); + struct power_supply_config psy_cfg = {}; + + info = devm_kzalloc(&pdev->dev, sizeof(*info), GFP_KERNEL); + if (!info) + return -ENOMEM; + + info->pdev = pdev; + info->regmap = axp20x->regmap; + info->regmap_irqc = axp20x->regmap_irqc; + info->status = POWER_SUPPLY_STATUS_UNKNOWN; + info->pdata = pdev->dev.platform_data; + if (!info->pdata) + return -ENODEV; + + platform_set_drvdata(pdev, info); + + mutex_init(&info->lock); + INIT_DELAYED_WORK(&info->status_monitor, fuel_gauge_status_monitor); + + psy_cfg.drv_data = info; + info->bat = power_supply_register(&pdev->dev, &fuel_gauge_desc, &psy_cfg); + if (IS_ERR(info->bat)) { + ret = PTR_ERR(info->bat); + dev_err(&pdev->dev, "failed to register battery: %d\n", ret); + return ret; + } + + fuel_gauge_create_debugfs(info); + fuel_gauge_init_config_regs(info); + fuel_gauge_init_irq(info); + fuel_gauge_init_hw_regs(info); + schedule_delayed_work(&info->status_monitor, STATUS_MON_DELAY_JIFFIES); + + return ret; +} + +static struct platform_device_id axp288_fg_id_table[] = { + { .name = DEV_NAME }, + {}, +}; + +static int axp288_fuel_gauge_remove(struct platform_device *pdev) +{ + struct axp288_fg_info *info = platform_get_drvdata(pdev); + int i; + + cancel_delayed_work_sync(&info->status_monitor); + power_supply_unregister(info->bat); + fuel_gauge_remove_debugfs(info); + + for (i = 0; i < AXP288_FG_INTR_NUM; i++) + if (info->irq[i] >= 0) + free_irq(info->irq[i], info); + + return 0; +} + +static struct platform_driver axp288_fuel_gauge_driver = { + .probe = axp288_fuel_gauge_probe, + .remove = axp288_fuel_gauge_remove, + .id_table = axp288_fg_id_table, + .driver = { + .name = DEV_NAME, + }, +}; + +module_platform_driver(axp288_fuel_gauge_driver); + +MODULE_AUTHOR("Todd Brandt <todd.e.brandt@linux.intel.com>"); +MODULE_DESCRIPTION("Xpower AXP288 Fuel Gauge Driver"); +MODULE_LICENSE("GPL"); |