diff options
Diffstat (limited to 'include')
-rw-r--r-- | include/linux/energy_model.h | 14 | ||||
-rw-r--r-- | include/linux/pm_domain.h | 8 |
2 files changed, 12 insertions, 10 deletions
diff --git a/include/linux/energy_model.h b/include/linux/energy_model.h index 3a33c738d876..757fc60658fa 100644 --- a/include/linux/energy_model.h +++ b/include/linux/energy_model.h @@ -13,9 +13,8 @@ /** * em_perf_state - Performance state of a performance domain * @frequency: The frequency in KHz, for consistency with CPUFreq - * @power: The power consumed at this level, in milli-watts (by 1 CPU or - by a registered device). It can be a total power: static and - dynamic. + * @power: The power consumed at this level (by 1 CPU or by a registered + * device). It can be a total power: static and dynamic. * @cost: The cost coefficient associated with this level, used during * energy calculation. Equal to: power * max_frequency / frequency */ @@ -58,7 +57,7 @@ struct em_data_callback { /** * active_power() - Provide power at the next performance state of * a device - * @power : Active power at the performance state in mW + * @power : Active power at the performance state * (modified) * @freq : Frequency at the performance state in kHz * (modified) @@ -69,8 +68,8 @@ struct em_data_callback { * and frequency. * * In case of CPUs, the power is the one of a single CPU in the domain, - * expressed in milli-watts. It is expected to fit in the - * [0, EM_MAX_POWER] range. + * expressed in milli-Watts or an abstract scale. It is expected to + * fit in the [0, EM_MAX_POWER] range. * * Return 0 on success. */ @@ -107,6 +106,9 @@ static inline unsigned long em_cpu_energy(struct em_perf_domain *pd, struct em_perf_state *ps; int i, cpu; + if (!sum_util) + return 0; + /* * In order to predict the performance state, map the utilization of * the most utilized CPU of the performance domain to a requested diff --git a/include/linux/pm_domain.h b/include/linux/pm_domain.h index 1ad0ec481416..a8f93328daec 100644 --- a/include/linux/pm_domain.h +++ b/include/linux/pm_domain.h @@ -280,11 +280,11 @@ static inline int dev_pm_genpd_remove_notifier(struct device *dev) #endif #ifdef CONFIG_PM_GENERIC_DOMAINS_SLEEP -void pm_genpd_syscore_poweroff(struct device *dev); -void pm_genpd_syscore_poweron(struct device *dev); +void dev_pm_genpd_suspend(struct device *dev); +void dev_pm_genpd_resume(struct device *dev); #else -static inline void pm_genpd_syscore_poweroff(struct device *dev) {} -static inline void pm_genpd_syscore_poweron(struct device *dev) {} +static inline void dev_pm_genpd_suspend(struct device *dev) {} +static inline void dev_pm_genpd_resume(struct device *dev) {} #endif /* OF PM domain providers */ |