summaryrefslogtreecommitdiffstats
path: root/kernel/sched
diff options
context:
space:
mode:
Diffstat (limited to 'kernel/sched')
-rw-r--r--kernel/sched/core.c8
-rw-r--r--kernel/sched/fair.c27
2 files changed, 28 insertions, 7 deletions
diff --git a/kernel/sched/core.c b/kernel/sched/core.c
index c1808606ee5f..e85cda20ab2b 100644
--- a/kernel/sched/core.c
+++ b/kernel/sched/core.c
@@ -2660,6 +2660,7 @@ asmlinkage void __sched notrace preempt_schedule(void)
} while (need_resched());
}
EXPORT_SYMBOL(preempt_schedule);
+#endif /* CONFIG_PREEMPT */
/*
* this is the entry point to schedule() from kernel preemption
@@ -2693,8 +2694,6 @@ asmlinkage void __sched preempt_schedule_irq(void)
exception_exit(prev_state);
}
-#endif /* CONFIG_PREEMPT */
-
int default_wake_function(wait_queue_t *curr, unsigned mode, int wake_flags,
void *key)
{
@@ -4762,7 +4761,7 @@ static void rq_attach_root(struct rq *rq, struct root_domain *rd)
cpumask_clear_cpu(rq->cpu, old_rd->span);
/*
- * If we dont want to free the old_rt yet then
+ * If we dont want to free the old_rd yet then
* set old_rd to NULL to skip the freeing later
* in this function:
*/
@@ -4910,8 +4909,9 @@ static void update_top_cache_domain(int cpu)
if (sd) {
id = cpumask_first(sched_domain_span(sd));
size = cpumask_weight(sched_domain_span(sd));
- rcu_assign_pointer(per_cpu(sd_busy, cpu), sd->parent);
+ sd = sd->parent; /* sd_busy */
}
+ rcu_assign_pointer(per_cpu(sd_busy, cpu), sd);
rcu_assign_pointer(per_cpu(sd_llc, cpu), sd);
per_cpu(sd_llc_size, cpu) = size;
diff --git a/kernel/sched/fair.c b/kernel/sched/fair.c
index e8b652ebe027..fd773ade1a31 100644
--- a/kernel/sched/fair.c
+++ b/kernel/sched/fair.c
@@ -5379,10 +5379,31 @@ void update_group_power(struct sched_domain *sd, int cpu)
*/
for_each_cpu(cpu, sched_group_cpus(sdg)) {
- struct sched_group *sg = cpu_rq(cpu)->sd->groups;
+ struct sched_group_power *sgp;
+ struct rq *rq = cpu_rq(cpu);
- power_orig += sg->sgp->power_orig;
- power += sg->sgp->power;
+ /*
+ * build_sched_domains() -> init_sched_groups_power()
+ * gets here before we've attached the domains to the
+ * runqueues.
+ *
+ * Use power_of(), which is set irrespective of domains
+ * in update_cpu_power().
+ *
+ * This avoids power/power_orig from being 0 and
+ * causing divide-by-zero issues on boot.
+ *
+ * Runtime updates will correct power_orig.
+ */
+ if (unlikely(!rq->sd)) {
+ power_orig += power_of(cpu);
+ power += power_of(cpu);
+ continue;
+ }
+
+ sgp = rq->sd->groups->sgp;
+ power_orig += sgp->power_orig;
+ power += sgp->power;
}
} else {
/*