2019-01-05dt-bindings: iio: adc: Add docs for AD7606 ADCStefan Popa2-0/+66
Document support for AD7606 Analog to Digital Converter. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05staging: iio: adc: ad7606: Move out of stagingStefan Popa9-31/+37
Move ad7606 ADC driver out of staging and into the mainline. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05staging: iio: adc: ad7606: Misc style fixes (no functional change)Stefan Popa4-43/+28
* Placed includes in alphabetical order * Added brackets around num and mask through out for AD760X_CHANNEL * Used single line comments where needed * Removed extra lines and spaces Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05staging: iio: adc: ad7606: Add support for threaded irqStefan Popa2-33/+84
This patch replaces the use of a polling ring buffer with a threaded interrupt. Enabling the buffer sets the CONVST signal to high. When the rising edge of the CONVST is applied, BUSY signal goes logic high and transitions low at the end of the entire conversion process. The falling edge of the BUSY signal triggers the interrupt. ad7606_trigger_handler() is used as bottom half of the poll function. It reads data from the device and stores it in the internal buffer. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05staging: iio: adc: ad7606: Use SPDX identifierStefan Popa4-8/+4
This patch replaces the license text at the top of ad7606 driver files and instead adds SPDX GPL-2.0 license identifier. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05staging: iio: adc: ad7606: Simplify the Kconfing menuStefan Popa1-17/+10
There is no point in having three menu entries that can be selected individually. Instead, the SPI and parallel interfaces should select AD7606. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05iio: ad9523: fix a missing check of return valueKangjie Lu1-2/+5
If ad9523_write() fails, indio_dev may get incorrect data. The fix inserts a check for the return value of ad9523_write(), and it fails, returns an error. Signed-off-by: Kangjie Lu <kjlu@umn.edu> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-01-05iio: chemical: sps30: add support for self cleaningTomasz Duszynski2-1/+42
Self cleaning is especially useful in cases where sensor undergoes frequent power on/off cycles. In such scenarios it is recommended to turn self cleaning at least once per week in order to maintain reliable measurements. Self cleaning is activated by writing 1 to a dedicated attribute. Internal fan accelerates to its maximum speed and keeps spinning for about 10 seconds blowing out accumulated dust. Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com> Tested-by: Andreas Brauchli <andreas.brauchli@sensirion.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-22iio: imu: st_lsm6dsx: remove set but not used variable ''YueHaibing1-2/+0
Fixes gcc '-Wunused-but-set-variable' warning: drivers/iio/imu/st_lsm6dsx/st_lsm6dsx_shub.c: In function 'st_lsm6dsx_shub_read_reg': drivers/iio/imu/st_lsm6dsx/st_lsm6dsx_shub.c:108:41: warning: variable 'hub_settings' set but not used [-Wunused-but-set-variable] It never used since introduction in commit c91c1c844ebd ("iio: imu: st_lsm6dsx: add i2c embedded controller support") Signed-off-by: YueHaibing <yuehaibing@huawei.com> Acked-by: Lorenzo Bianconi <lorenzo.bianconi83@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-22staging: iio: adc: ad7606: Add OF device ID tableStefan Popa2-0/+20
The driver does not have a struct of_device_id table, but supported devices are registered via Device Trees. This patch adds and OF device ID table. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-22staging: iio: adc: ad7606: Use vendor prefix for DT propertiesStefan Popa1-4/+6
The 'adi' vendor prefix needs to be added to conversion-start, range, first-data and oversampling-ratio properties. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-22staging: iio: adc: ad7606: Use find_closest() macroStefan Popa1-36/+22
When looking for the available scale or oversampling ratio, it is better to use the find_closest() macro. This simplifies the code and also does not require an exact value to be entered from the user space. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-22staging: iio: adc: ad7606: Use devm functions in probeStefan Popa4-51/+21
Switch to devm version of request_irq, iio_triggered_buffer_setup, iio_device_register. To avoid potential ordering issues in probe, devm_add_action_or_reset() is used for the regulator_disable(). This simplifies the code and decreases the chance of bugs. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-22staging: iio: adc: ad7606: Use wait-for-completion handlerStefan Popa2-11/+9
This patch replaces the use of wait_event_interruptible() with wait_for_completion_timeout() when reading the result of a single conversion. In this way, if the interrupt never occurs, the program will not remain blocked. Signed-off-by: Stefan Popa <stefan.popa@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>