Using the BIT macro makes the code a little easier to read.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
|
|
|
|
|
| |
MAX34460 is a PMBus 12-Channel Voltage Monitor & Sequencer.
MAX34461 is a PMBus 16-Channel Voltage Monitor & Sequencer.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
|
|
| |
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
|
|
|
|
|
|
| |
MAX34440 and compatibles support reporting the lowest measured output voltage.
Add support for it.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Acked-by: Jean Delvare <khali@linux-fr.org>
|
|
|
|
|
|
|
|
|
| |
Since devm_kzalloc() is now used to allocate driver memory, the client
driver remove function has no purpose other than to call pmbus_do_remove().
This means we can get rid of it by redefining pmbus_do_remove() to use the
same prototype, and pointing to it directly.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This patch converts the drivers in drivers/hwmon/* to use the
module_i2c_driver() macro which makes the code smaller and a bit simpler.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Cc: Corentin Labbe <corentin.labbe@geomatys.fr>
Cc: Dirk Eibach <eibach@gdsys.de>
Cc: "Mark M. Hoffman" <mhoffman@lightlink.com>
Cc: Steve Glendinning <steve.glendinning@smsc.com>
Cc: Riku Voipio <riku.voipio@iki.fi>
Cc: Guillaume Ligneul <guillaume.ligneul@gmail.com>
Cc: David George <david.george@ska.ac.za>
Cc: "Hans J. Koch" <hjk@hansjkoch.de>
Cc: Marc Hulsman <m.hulsman@tudelft.nl>
Cc: Rudolf Marek <r.marek@assembler.cz>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
|
|
|
|
|
|
|
|
| |
Temperature history is reset by writing 0x8000 into the peak temperature
register, not 0xffff.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Acked-by: Jean Delvare <khali@linux-fr.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Always call _pmbus_read_byte() instead of pmbus_read_byte() in PMBus core
driver. With this change, device specific read functions can be implemented for
all registers.
Since the device specific read_byte function is now always called, we need to be
more careful with page validations. Only fail if the passed page number is larger
than 0, since -1 means "current page".
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Driver remove functions have an error return value, but rarely return an error
in practice. If a driver does return an error from its remove function, the
driver won't be unloaded and is expected to stay alive.
pmbus_do_remove() is defined as returning an int, but always returns 0 (no
error). Calling code passes that return value on to high level driver
remove functions, but does not evaluate it and removes driver data even if
pmbus_do_remove() returned an error (which it in practice never does). Even if
this code could never cause a real problem, it is nevertheless conceptually
wrong.
To reduce confusion and simplify the code, change pmbus_do_remove() to be a void
function, and have PMBus client drivers always return zero in their driver
remove functions.
Reported-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
|
|
|
|
|
|
|
|
| |
Add support for voltage, current, and temperature peak (historic maximum)
attributes.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
|
|
|
|
|
|
|
|
|
|
|
|
| |
In VID mode, output voltages are measured and reported as VID values, and
have to be converted to voltages using VID conversion tables or functions.
Support is added for VR11 only at this time.
This patch enables support for PMBus devices supporting VID VR11 based output
voltage selection such as NCP4200 and NCP4208.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
|
|
Since the number of PMBus drivers is getting large, move them into
directory drivers/hwmon/pmbus to improve readability and scalability.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
|