From 25f2bfa62ae77820a8185734c4a2ab7f3971a2fc Mon Sep 17 00:00:00 2001
From: Daniel Mack <daniel@caiaq.de>
Date: Wed, 15 Jul 2009 18:20:41 +0200
Subject: ds2760_battery: handle full_active_uAh == 0 case correctly

In systems where the battery monitor is not part of the battery pack and
is hence not bootstrapped with sane values, the full_active_uAh is
likely to be zero.

Handle that case by defaulting to the rated_capacity information which
can be passed to the driver using the new module parameter.

Signed-off-by: Daniel Mack <daniel@caiaq.de>
Cc: Szabolcs Gyurko <szabolcs.gyurko@tlt.hu>
Acked-by: Matt Reimer <mreimer@vpop.net>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
---
 drivers/power/ds2760_battery.c | 9 +++++++--
 1 file changed, 7 insertions(+), 2 deletions(-)

diff --git a/drivers/power/ds2760_battery.c b/drivers/power/ds2760_battery.c
index ed0ea5e275c5..2d0e5edb4742 100644
--- a/drivers/power/ds2760_battery.c
+++ b/drivers/power/ds2760_battery.c
@@ -172,8 +172,13 @@ static int ds2760_battery_read_status(struct ds2760_device_info *di)
 	di->full_active_uAh = di->raw[DS2760_ACTIVE_FULL] << 8 |
 			      di->raw[DS2760_ACTIVE_FULL + 1];
 
-	scale[0] = di->raw[DS2760_ACTIVE_FULL] << 8 |
-		   di->raw[DS2760_ACTIVE_FULL + 1];
+	/* If the full_active_uAh value is not given, fall back to the rated
+	 * capacity. This is likely to happen when chips are not part of the
+	 * battery pack and is therefore not bootstrapped. */
+	if (di->full_active_uAh == 0)
+		di->full_active_uAh = di->rated_capacity / 1000L;
+
+	scale[0] = di->full_active_uAh;
 	for (i = 1; i < 5; i++)
 		scale[i] = scale[i - 1] + di->raw[DS2760_ACTIVE_FULL + 2 + i];
 
-- 
cgit v1.2.3