From 3824c47714f28091f74ca2505146514b4da1f390 Mon Sep 17 00:00:00 2001 From: Ramakrishna Pallala Date: Sun, 6 May 2012 18:16:44 +0530 Subject: power_supply: Add constant charge_current and charge_voltage properties Constant Charge Current(CC) is charging parameter which limit the maximum current which can be pumped into the battery during charge cycle. Constant Charge Voltage(CV) is also charging parameter which limit the maximum voltage that battery can reach during charge cycle. It is very common practice that at low or high temperatures we do not charge the batteries upto it's fullest charge voltage to avoid battery and user safety issues. These sysfs properties will be useful for debug and to implement certain user space policies like "Charging limited due to OverTemp". Signed-off-by: Ramakrishna Pallala Signed-off-by: Anton Vorontsov --- Documentation/power/power_supply_class.txt | 4 ++++ 1 file changed, 4 insertions(+) (limited to 'Documentation/power') diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index 211831d4095f..c0f62ae2b5e0 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt @@ -112,6 +112,10 @@ CHARGE_COUNTER - the current charge counter (in µAh). This could easily be negative; there is no empty or full value. It is only useful for relative, time-based measurements. +CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger. + +CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger. + ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. CAPACITY - capacity in percents. -- cgit v1.2.3