From 25f2bfa62ae77820a8185734c4a2ab7f3971a2fc Mon Sep 17 00:00:00 2001 From: Daniel Mack Date: Wed, 15 Jul 2009 18:20:41 +0200 Subject: ds2760_battery: handle full_active_uAh == 0 case correctly In systems where the battery monitor is not part of the battery pack and is hence not bootstrapped with sane values, the full_active_uAh is likely to be zero. Handle that case by defaulting to the rated_capacity information which can be passed to the driver using the new module parameter. Signed-off-by: Daniel Mack Cc: Szabolcs Gyurko Acked-by: Matt Reimer Signed-off-by: Anton Vorontsov --- drivers/power/ds2760_battery.c | 9 +++++++-- 1 file changed, 7 insertions(+), 2 deletions(-) (limited to 'drivers/power/ds2760_battery.c') diff --git a/drivers/power/ds2760_battery.c b/drivers/power/ds2760_battery.c index ed0ea5e275c5..2d0e5edb4742 100644 --- a/drivers/power/ds2760_battery.c +++ b/drivers/power/ds2760_battery.c @@ -172,8 +172,13 @@ static int ds2760_battery_read_status(struct ds2760_device_info *di) di->full_active_uAh = di->raw[DS2760_ACTIVE_FULL] << 8 | di->raw[DS2760_ACTIVE_FULL + 1]; - scale[0] = di->raw[DS2760_ACTIVE_FULL] << 8 | - di->raw[DS2760_ACTIVE_FULL + 1]; + /* If the full_active_uAh value is not given, fall back to the rated + * capacity. This is likely to happen when chips are not part of the + * battery pack and is therefore not bootstrapped. */ + if (di->full_active_uAh == 0) + di->full_active_uAh = di->rated_capacity / 1000L; + + scale[0] = di->full_active_uAh; for (i = 1; i < 5; i++) scale[i] = scale[i - 1] + di->raw[DS2760_ACTIVE_FULL + 2 + i]; -- cgit v1.2.3