From 0873a5ae747847ee55a63db409dff3476e45bcd9 Mon Sep 17 00:00:00 2001 From: "Erik J. Staab" Date: Wed, 22 Sep 2010 11:07:41 +0200 Subject: ALSA: oxygen: fix analog capture on Claro halo cards On the HT-Omega Claro halo card, the ADC data must be captured from the second I2S input. Using the default first input, which isn't connected to anything, would result in silence. Signed-off-by: Erik J. Staab Signed-off-by: Clemens Ladisch Cc: Signed-off-by: Takashi Iwai --- sound/pci/oxygen/oxygen.c | 4 ++++ 1 file changed, 4 insertions(+) (limited to 'sound/pci/oxygen') diff --git a/sound/pci/oxygen/oxygen.c b/sound/pci/oxygen/oxygen.c index 289cb4dacfc7..6c0a11adb2a8 100644 --- a/sound/pci/oxygen/oxygen.c +++ b/sound/pci/oxygen/oxygen.c @@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip, chip->model.suspend = claro_suspend; chip->model.resume = claro_resume; chip->model.set_adc_params = set_ak5385_params; + chip->model.device_config = PLAYBACK_0_TO_I2S | + PLAYBACK_1_TO_SPDIF | + CAPTURE_0_FROM_I2S_2 | + CAPTURE_1_FROM_SPDIF; break; } if (id->driver_data == MODEL_MERIDIAN || -- cgit v1.2.3