Kernel driver ibm-cffps
=======================

Supported chips:

  * IBM Common Form Factor power supply

Author: Eddie James <eajames@us.ibm.com>

Description
-----------

This driver supports IBM Common Form Factor (CFF) power supplies. This driver
is a client to the core PMBus driver.

Usage Notes
-----------

This driver does not auto-detect devices. You will have to instantiate the
devices explicitly. Please see Documentation/i2c/instantiating-devices for
details.

Sysfs entries
-------------

The following attributes are supported:

======================= ======================================================
curr1_alarm		Output current over-current alarm.
curr1_input		Measured output current in mA.
curr1_label		"iout1"

fan1_alarm		Fan 1 warning.
fan1_fault		Fan 1 fault.
fan1_input		Fan 1 speed in RPM.
fan2_alarm		Fan 2 warning.
fan2_fault		Fan 2 fault.
fan2_input		Fan 2 speed in RPM.

in1_alarm		Input voltage under-voltage alarm.
in1_input		Measured input voltage in mV.
in1_label		"vin"
in2_alarm		Output voltage over-voltage alarm.
in2_input		Measured output voltage in mV.
in2_label		"vout1"

power1_alarm		Input fault or alarm.
power1_input		Measured input power in uW.
power1_label		"pin"

temp1_alarm		PSU inlet ambient temperature over-temperature alarm.
temp1_input		Measured PSU inlet ambient temp in millidegrees C.
temp2_alarm		Secondary rectifier temp over-temperature alarm.
temp2_input		Measured secondary rectifier temp in millidegrees C.
temp3_alarm		ORing FET temperature over-temperature alarm.
temp3_input		Measured ORing FET temperature in millidegrees C.
======================= ======================================================