summaryrefslogtreecommitdiffstats
path: root/man/sd_bus_get_fd.xml
blob: c7bab0f95581953f9c0b7d825f5b275c32de6cff (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
<?xml version='1.0'?>
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
  "http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd">

<!--
  SPDX-License-Identifier: LGPL-2.1-or-later

  Copyright © 2016 Julian Orth
-->

<refentry id="sd_bus_get_fd" xmlns:xi="http://www.w3.org/2001/XInclude">

  <refentryinfo>
    <title>sd_bus_get_fd</title>
    <productname>systemd</productname>
  </refentryinfo>

  <refmeta>
    <refentrytitle>sd_bus_get_fd</refentrytitle>
    <manvolnum>3</manvolnum>
  </refmeta>

  <refnamediv>
    <refname>sd_bus_get_fd</refname>
    <refname>sd_bus_get_events</refname>
    <refname>sd_bus_get_timeout</refname>

    <refpurpose>Get the file descriptor, I/O events and timeout to wait for from a message bus
    object</refpurpose>
  </refnamediv>

  <refsynopsisdiv>
    <funcsynopsis>
      <funcsynopsisinfo>#include &lt;systemd/sd-bus.h&gt;</funcsynopsisinfo>

      <funcprototype>
        <funcdef>int <function>sd_bus_get_fd</function></funcdef>
        <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
      </funcprototype>

      <funcprototype>
        <funcdef>int <function>sd_bus_get_events</function></funcdef>
        <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
      </funcprototype>

      <funcprototype>
        <funcdef>int <function>sd_bus_get_timeout</function></funcdef>
        <paramdef>sd_bus *<parameter>bus</parameter></paramdef>
        <paramdef>uint64_t *<parameter>timeout_usec</parameter></paramdef>
      </funcprototype>
    </funcsynopsis>
  </refsynopsisdiv>

  <refsect1>
    <title>Description</title>

    <para><function>sd_bus_get_fd()</function> returns the file descriptor used to communicate from
    a message bus object. This descriptor can be used with
    <citerefentry project='man-pages'><refentrytitle>poll</refentrytitle><manvolnum>3</manvolnum></citerefentry>
    or a similar function to wait for I/O events on the specified bus connection object. If the bus
    object was configured with the <function>sd_bus_set_fd()</function> function, then the
    <parameter>input_fd</parameter> file descriptor used in that call is returned.</para>

    <para><function>sd_bus_get_events()</function> returns the I/O events to wait for, suitable for
    passing to <function>poll()</function> or a similar call. Returns a combination of
    <constant>POLLIN</constant>, <constant>POLLOUT</constant>,  events, or negative on error.
    </para>

    <para><function>sd_bus_get_timeout()</function> returns the <emphasis>absolute</emphasis> timeout in μs,
    from which the relative timeout to pass to <function>poll()</function> (or a similar call) can be
    derived, when waiting for events on the specified bus connection. The returned timeout may be zero, in
    which case a subsequent I/O polling call should be invoked in non-blocking mode. The returned timeout may
    be <constant>UINT64_MAX</constant> in which case the I/O polling call may block indefinitely, without any
    applied timeout. Note that the returned timeout should be considered only a maximum sleeping time. It is
    permissible (and even expected) that shorter timeouts are used by the calling program, in case other
    event sources are polled in the same event loop. Note that the returned time-value is absolute, based of
    <constant>CLOCK_MONOTONIC</constant> and specified in microseconds. When converting this value in order
    to pass it as third argument to <function>poll()</function> (which expects relative milliseconds), care
    should be taken to convert to a relative time and use a division that rounds up to ensure the I/O polling
    operation doesn't sleep for shorter than necessary, which might result in unintended busy looping
    (alternatively, use <citerefentry
    project='man-pages'><refentrytitle>ppoll</refentrytitle><manvolnum>2</manvolnum></citerefentry> instead
    of plain <function>poll()</function>, which understands timeouts with nano-second granularity).</para>

    <para>These three functions are useful to hook up a bus connection object with an external or
    manual event loop involving <function>poll()</function> or a similar I/O polling call. Before
    each invocation of the I/O polling call, all three functions should be invoked: the file
    descriptor returned by <function>sd_bus_get_fd()</function> should be polled for the events
    indicated by <function>sd_bus_get_events()</function>, and the I/O call should block for that up
    to the timeout returned by <function>sd_bus_get_timeout()</function>. After each I/O polling
    call the bus connection needs to process incoming or outgoing data, by invoking
    <citerefentry><refentrytitle>sd_bus_process</refentrytitle><manvolnum>3</manvolnum></citerefentry>.
    </para>

    <para>Note that these functions are only one of three supported ways to implement I/O event
    handling for bus connections. Alternatively use
    <citerefentry><refentrytitle>sd_bus_attach_event</refentrytitle><manvolnum>3</manvolnum></citerefentry>
    to attach a bus connection to an
    <citerefentry><refentrytitle>sd-event</refentrytitle><manvolnum>3</manvolnum></citerefentry>
    event loop. Or use
    <citerefentry><refentrytitle>sd_bus_wait</refentrytitle><manvolnum>3</manvolnum></citerefentry>
    as a simple synchronous, blocking I/O waiting call.</para>
  </refsect1>

  <refsect1>
    <title>Return Value</title>

    <para>On success, <function>sd_bus_get_fd()</function> returns the file descriptor used for
    communication. On failure, it returns a negative errno-style error code.</para>

    <para>On success, <function>sd_bus_get_events()</function> returns the I/O event mask to use for
    I/O event watching. On failure, it returns a negative errno-style error code.</para>

    <para>On success, <function>sd_bus_get_timeout()</function> returns a non-negative integer. On
    failure, it returns a negative errno-style error code.</para>

    <refsect2>
      <title>Errors</title>

      <para>Returned errors may indicate the following problems:</para>

      <variablelist>
        <varlistentry>
          <term><constant>-EINVAL</constant></term>

          <listitem><para>An invalid bus object was passed.</para></listitem>
        </varlistentry>

        <varlistentry>
          <term><constant>-ECHILD</constant></term>

          <listitem><para>The bus connection was allocated in a parent process and is being reused
          in a child process after <function>fork()</function>.</para></listitem>
        </varlistentry>

        <varlistentry>
          <term><constant>-ENOTCONN</constant></term>

          <listitem><para>The bus connection has been terminated.</para></listitem>
        </varlistentry>

        <varlistentry>
          <term><constant>-EPERM</constant></term>

          <listitem><para>Two distinct file descriptors were passed for input and output using
          <function>sd_bus_set_fd()</function>, which <function>sd_bus_get_fd()</function> cannot
          return.</para></listitem>
        </varlistentry>

        <varlistentry>
          <term><constant>-ENOPKG</constant></term>

          <listitem><para>The bus cannot be resolved.</para></listitem>
        </varlistentry>
      </variablelist>
    </refsect2>
  </refsect1>

  <xi:include href="libsystemd-pkgconfig.xml" />

  <refsect1>
    <title>History</title>
    <para><function>sd_bus_get_fd()</function>,
    <function>sd_bus_get_events()</function>, and
    <function>sd_bus_get_timeout()</function> were added in version 221.</para>
  </refsect1>

  <refsect1>
    <title>See Also</title>

    <para><simplelist type="inline">
      <member><citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
      <member><citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
      <member><citerefentry><refentrytitle>sd_bus_process</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
      <member><citerefentry><refentrytitle>sd_bus_attach_event</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
      <member><citerefentry><refentrytitle>sd_bus_wait</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
      <member><citerefentry><refentrytitle>sd_bus_set_fd</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
      <member><citerefentry project='man-pages'><refentrytitle>poll</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
    </simplelist></para>
  </refsect1>

</refentry>