diff options
author | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2023-03-17 18:03:40 +0100 |
---|---|---|
committer | Rafael J. Wysocki <rafael.j.wysocki@intel.com> | 2023-03-22 15:20:38 +0100 |
commit | 22c52fa5155a2f48aedb0f675903b20457285a27 (patch) | |
tree | c0d2dfd9154f69dd0a6ccf2c3bac595712c6c41f | |
parent | thermal: core: Introduce thermal_cooling_device_update() (diff) | |
download | linux-22c52fa5155a2f48aedb0f675903b20457285a27.tar.xz linux-22c52fa5155a2f48aedb0f675903b20457285a27.zip |
ACPI: processor: thermal: Update CPU cooling devices on cpufreq policy changes
When a cpufreq policy appears or goes away, the CPU cooling devices for
the CPUs covered by that policy need to be updated so that the new
processor_get_max_state() value is stored as max_state and the
statistics in sysfs are rearranged for each of them.
Do that accordingly in acpi_thermal_cpufreq_init() and
acpi_thermal_cpufreq_exit().
Fixes: a365105c685c("thermal: sysfs: Reuse cdev->max_state")
Reported-by: Wang, Quanxian <quanxian.wang@intel.com>
Link: https://lore.kernel.org/linux-pm/53ec1f06f61c984100868926f282647e57ecfb2d.camel@intel.com
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Tested-by: Zhang Rui <rui.zhang@intel.com>
Reviewed-by: Zhang Rui <rui.zhang@intel.com>
-rw-r--r-- | drivers/acpi/processor_thermal.c | 14 |
1 files changed, 11 insertions, 3 deletions
diff --git a/drivers/acpi/processor_thermal.c b/drivers/acpi/processor_thermal.c index e534fd49a67e..b7c6287eccca 100644 --- a/drivers/acpi/processor_thermal.c +++ b/drivers/acpi/processor_thermal.c @@ -140,9 +140,13 @@ void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy) ret = freq_qos_add_request(&policy->constraints, &pr->thermal_req, FREQ_QOS_MAX, INT_MAX); - if (ret < 0) + if (ret < 0) { pr_err("Failed to add freq constraint for CPU%d (%d)\n", cpu, ret); + continue; + } + + thermal_cooling_device_update(pr->cdev); } } @@ -153,8 +157,12 @@ void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy) for_each_cpu(cpu, policy->related_cpus) { struct acpi_processor *pr = per_cpu(processors, cpu); - if (pr) - freq_qos_remove_request(&pr->thermal_req); + if (!pr) + continue; + + freq_qos_remove_request(&pr->thermal_req); + + thermal_cooling_device_update(pr->cdev); } } #else /* ! CONFIG_CPU_FREQ */ |