hwmon: (max31827) Handle new properties from the devicetree
Used fwnode to retrieve data from the devicetree in the init_client function. If the uint32 properties are not present, the default values are used for max31827 chip. Signed-off-by: Daniel Matyas <daniel.matyas@analog.com> Link: https://lore.kernel.org/r/20231031182158.124608-1-daniel.matyas@analog.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
-rw-r--r--Documentation/hwmon/max31827.rst48
-rw-r--r--drivers/hwmon/max31827.c75
2 files changed, 108 insertions, 15 deletions
diff --git a/Documentation/hwmon/max31827.rst b/Documentation/hwmon/max31827.rst
index 9a1055a007cf..a8bbfb85dd02 100644
--- a/Documentation/hwmon/max31827.rst
+++ b/Documentation/hwmon/max31827.rst
@@ -52,13 +52,21 @@ MAX31827 has low and over temperature alarms with an effective value and a
hysteresis value: -40 and -30 degrees for under temperature alarm and +100 and
+90 degrees for over temperature alarm.
-The alarm can be configured in comparator and interrupt mode. Currently only
-comparator mode is implemented. In Comparator mode, the OT/UT status bits have a
-value of 1 when the temperature rises above the TH value or falls below TL,
-which is also subject to the Fault Queue selection. OT status returns to 0 when
-the temperature drops below the TH_HYST value or when shutdown mode is entered.
-Similarly, UT status returns to 0 when the temperature rises above TL_HYST value
-or when shutdown mode is entered.
+The alarm can be configured in comparator and interrupt mode from the
+devicetree. In Comparator mode, the OT/UT status bits have a value of 1 when the
+temperature rises above the TH value or falls below TL, which is also subject to
+the Fault Queue selection. OT status returns to 0 when the temperature drops
+below the TH_HYST value or when shutdown mode is entered. Similarly, UT status
+returns to 0 when the temperature rises above TL_HYST value or when shutdown
+mode is entered.
+
+In interrupt mode exceeding TH also sets OT status to 1, which remains set until
+a read operation is performed on the configuration/status register (max or min
+attribute); at this point, it returns to 0. Once OT status is set to 1 from
+exceeding TH and reset, it is set to 1 again only when the temperature drops
+below TH_HYST. The output remains asserted until it is reset by a read. It is
+set again if the temperature rises above TH, and so on. The same logic applies
+to the operation of the UT status bit.
Putting the MAX31827 into shutdown mode also resets the OT/UT status bits. Note
that if the mode is changed while OT/UT status bits are set, an OT/UT status
@@ -68,6 +76,18 @@ clear the status bits before changing the operating mode.
The conversions can be manual with the one-shot functionality and automatic with
a set frequency. When powered on, the chip measures temperatures with 1 conv/s.
+The conversion rate can be modified with update_interval attribute of the chip.
+Conversion/second = 1/update_interval. Thus, the available options according to
+the data sheet are:
+
+- 64000 (ms) = 1 conv/64 sec
+- 32000 (ms) = 1 conv/32 sec
+- 16000 (ms) = 1 conv/16 sec
+- 4000 (ms) = 1 conv/4 sec
+- 1000 (ms) = 1 conv/sec (default)
+- 250 (ms) = 4 conv/sec
+- 125 (ms) = 8 conv/sec
+
Enabling the device when it is already enabled has the side effect of setting
the conversion frequency to 1 conv/s. The conversion time varies depending on
the resolution. The conversion time doubles with every bit of increased
@@ -83,8 +103,18 @@ in the writing of alarm values too. For positive numbers the user-input value
will always be rounded down to the nearest possible value, for negative numbers
the user-input will always be rounded up to the nearest possible value.
+Bus timeout resets the I2C-compatible interface when SCL is low for more than
+30ms (nominal).
+
+Alarm polarity determines if the active state of the alarm is low or high. The
+behavior for both settings is dependent on the Fault Queue setting. The ALARM
+pin is an open-drain output and requires a pullup resistor to operate.
+
+The Fault Queue bits select how many consecutive temperature faults must occur
+before overtemperature or undertemperature faults are indicated in the
+corresponding status bits.
+
Notes
-----
-Currently fault queue, alarm polarity and resolution cannot be modified.
-PEC is not implemented either.
+PEC and resolution are not implemented.
diff --git a/drivers/hwmon/max31827.c b/drivers/hwmon/max31827.c
index a1ce65145669..3f1312b555ab 100644
--- a/drivers/hwmon/max31827.c
+++ b/drivers/hwmon/max31827.c
@@ -11,6 +11,7 @@
#include <linux/hwmon.h>
#include <linux/i2c.h>
#include <linux/mutex.h>
+#include <linux/of_device.h>
#include <linux/regmap.h>
#include <linux/regulator/consumer.h>
@@ -23,9 +24,17 @@
#define MAX31827_CONFIGURATION_1SHOT_MASK BIT(0)
#define MAX31827_CONFIGURATION_CNV_RATE_MASK GENMASK(3, 1)
+#define MAX31827_CONFIGURATION_TIMEOUT_MASK BIT(5)
+#define MAX31827_CONFIGURATION_RESOLUTION_MASK GENMASK(7, 6)
+#define MAX31827_CONFIGURATION_ALRM_POL_MASK BIT(8)
+#define MAX31827_CONFIGURATION_COMP_INT_MASK BIT(9)
+#define MAX31827_CONFIGURATION_FLT_Q_MASK GENMASK(11, 10)
#define MAX31827_CONFIGURATION_U_TEMP_STAT_MASK BIT(14)
#define MAX31827_CONFIGURATION_O_TEMP_STAT_MASK BIT(15)
+#define MAX31827_ALRM_POL_LOW 0x0
+#define MAX31827_FLT_Q_1 0x0
+
#define MAX31827_12_BIT_CNV_TIME 140
#define MAX31827_16_BIT_TO_M_DGR(x) (sign_extend32(x, 15) * 1000 / 16)
@@ -362,14 +371,68 @@ static int max31827_write(struct device *dev, enum hwmon_sensor_types type,
return -EOPNOTSUPP;
}
-static int max31827_init_client(struct max31827_state *st)
+static int max31827_init_client(struct max31827_state *st,
+ struct device *dev)
{
+ struct fwnode_handle *fwnode;
+ unsigned int res = 0;
+ u32 data, lsb_idx;
+ bool prop;
+ int ret;
+
+ fwnode = dev_fwnode(dev);
+
st->enable = true;
+ res |= MAX31827_DEVICE_ENABLE(1);
+
+ res |= MAX31827_CONFIGURATION_RESOLUTION_MASK;
+
+ prop = fwnode_property_read_bool(fwnode, "adi,comp-int");
+ res |= FIELD_PREP(MAX31827_CONFIGURATION_COMP_INT_MASK, prop);
+
+ prop = fwnode_property_read_bool(fwnode, "adi,timeout-enable");
+ res |= FIELD_PREP(MAX31827_CONFIGURATION_TIMEOUT_MASK, !prop);
+
+ if (fwnode_property_present(fwnode, "adi,alarm-pol")) {
+ ret = fwnode_property_read_u32(fwnode, "adi,alarm-pol", &data);
+ if (ret)
+ return ret;
+
+ res |= FIELD_PREP(MAX31827_CONFIGURATION_ALRM_POL_MASK, !!data);
+ } else {
+ /*
+ * Set default value.
+ */
+ res |= FIELD_PREP(MAX31827_CONFIGURATION_ALRM_POL_MASK,
+ MAX31827_ALRM_POL_LOW);
+ }
+
+ if (fwnode_property_present(fwnode, "adi,fault-q")) {
+ ret = fwnode_property_read_u32(fwnode, "adi,fault-q", &data);
+ if (ret)
+ return ret;
+
+ /*
+ * Convert the desired fault queue into register bits.
+ */
+ if (data != 0)
+ lsb_idx = __ffs(data);
+
+ if (hweight32(data) != 1 || lsb_idx > 4) {
+ dev_err(dev, "Invalid data in adi,fault-q\n");
+ return -EINVAL;
+ }
+
+ res |= FIELD_PREP(MAX31827_CONFIGURATION_FLT_Q_MASK, lsb_idx);
+ } else {
+ /*
+ * Set default value.
+ */
+ res |= FIELD_PREP(MAX31827_CONFIGURATION_FLT_Q_MASK,
+ MAX31827_FLT_Q_1);
+ }
- return regmap_update_bits(st->regmap, MAX31827_CONFIGURATION_REG,
- MAX31827_CONFIGURATION_1SHOT_MASK |
- MAX31827_CONFIGURATION_CNV_RATE_MASK,
- MAX31827_DEVICE_ENABLE(1));
+ return regmap_write(st->regmap, MAX31827_CONFIGURATION_REG, res);
}
static const struct hwmon_channel_info *max31827_info[] = {
@@ -417,7 +480,7 @@ static int max31827_probe(struct i2c_client *client)
if (err)
return dev_err_probe(dev, err, "failed to enable regulator\n");
- err = max31827_init_client(st);
+ err = max31827_init_client(st, dev);
if (err)
return err;