diff options
author | Sachin Kamat <sachin.kamat@linaro.org> | 2014-02-14 12:49:52 +0100 |
---|---|---|
committer | Mark Brown <broonie@linaro.org> | 2014-02-14 22:11:39 +0100 |
commit | c0a3536317357e29c52e32f150114adbce19507b (patch) | |
tree | 8b5b18b78b5591c48444d5427baadff0f05c4625 | |
parent | Linus 3.14-rc1 (diff) | |
download | linux-c0a3536317357e29c52e32f150114adbce19507b.tar.xz linux-c0a3536317357e29c52e32f150114adbce19507b.zip |
regulator: max8997: Use of_get_child_by_name
of_find_node_by_name walks the allnodes list, and can thus walk
outside of the parent node. Use of_get_child_by_name instead.
Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
Signed-off-by: Mark Brown <broonie@linaro.org>
-rw-r--r-- | drivers/regulator/max8997.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/regulator/max8997.c b/drivers/regulator/max8997.c index 2d618fc9c1af..10108f2941e3 100644 --- a/drivers/regulator/max8997.c +++ b/drivers/regulator/max8997.c @@ -924,7 +924,7 @@ static int max8997_pmic_dt_parse_pdata(struct platform_device *pdev, return -ENODEV; } - regulators_np = of_find_node_by_name(pmic_np, "regulators"); + regulators_np = of_get_child_by_name(pmic_np, "regulators"); if (!regulators_np) { dev_err(&pdev->dev, "could not find regulators sub-node\n"); return -EINVAL; |