summaryrefslogtreecommitdiffstats
path: root/Documentation/devicetree/bindings/powerpc
diff options
context:
space:
mode:
authorTimur Tabi <timur@freescale.com>2011-09-23 19:41:35 +0200
committerKumar Gala <galak@kernel.crashing.org>2011-10-14 09:54:29 +0200
commit2bcd1c0cfcf53a384159c272c972645e7e822140 (patch)
tree221e336531b92f2eef53cd48a1c1ad217ccf894b /Documentation/devicetree/bindings/powerpc
parentpowerpc/85xx: Setup secondary cores PIR with hard SMP id (diff)
downloadlinux-2bcd1c0cfcf53a384159c272c972645e7e822140.tar.xz
linux-2bcd1c0cfcf53a384159c272c972645e7e822140.zip
powerpc/fsl_msi: add support for "msi-address-64" property
Add support for the msi-address-64 property of a PCI node. This property specifies the PCI address of MSIIR (message signaled interrupt index register). In commit 3da34aae ("powerpc/fsl: Support unique MSI addresses per PCIe Root Complex"), the msi_addr_hi/msi_addr_lo fields of struct fsl_msi were redefined from an actual address to just an offset, but the fields were not renamed accordingly. These fields are replace with a single field, msiir_offset, to reflect the new meaning. Signed-off-by: Timur Tabi <timur@freescale.com> Signed-off-by: Kumar Gala <galak@kernel.crashing.org>
Diffstat (limited to 'Documentation/devicetree/bindings/powerpc')
-rw-r--r--Documentation/devicetree/bindings/powerpc/fsl/msi-pic.txt42
1 files changed, 42 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/powerpc/fsl/msi-pic.txt b/Documentation/devicetree/bindings/powerpc/fsl/msi-pic.txt
index 70558c3f3682..5d586e1ccaf5 100644
--- a/Documentation/devicetree/bindings/powerpc/fsl/msi-pic.txt
+++ b/Documentation/devicetree/bindings/powerpc/fsl/msi-pic.txt
@@ -25,6 +25,16 @@ Required properties:
are routed to IPIC, and for 85xx/86xx cpu the interrupts are routed
to MPIC.
+Optional properties:
+- msi-address-64: 64-bit PCI address of the MSIIR register. The MSIIR register
+ is used for MSI messaging. The address of MSIIR in PCI address space is
+ the MSI message address.
+
+ This property may be used in virtualized environments where the hypervisor
+ has created an alternate mapping for the MSIR block. See below for an
+ explanation.
+
+
Example:
msi@41600 {
compatible = "fsl,mpc8610-msi", "fsl,mpic-msi";
@@ -41,3 +51,35 @@ Example:
0xe7 0>;
interrupt-parent = <&mpic>;
};
+
+The Freescale hypervisor and msi-address-64
+-------------------------------------------
+Normally, PCI devices have access to all of CCSR via an ATMU mapping. The
+Freescale MSI driver calculates the address of MSIIR (in the MSI register
+block) and sets that address as the MSI message address.
+
+In a virtualized environment, the hypervisor may need to create an IOMMU
+mapping for MSIIR. The Freescale ePAPR hypervisor has this requirement
+because of hardware limitations of the Peripheral Access Management Unit
+(PAMU), which is currently the only IOMMU that the hypervisor supports.
+The ATMU is programmed with the guest physical address, and the PAMU
+intercepts transactions and reroutes them to the true physical address.
+
+In the PAMU, each PCI controller is given only one primary window. The
+PAMU restricts DMA operations so that they can only occur within a window.
+Because PCI devices must be able to DMA to memory, the primary window must
+be used to cover all of the guest's memory space.
+
+PAMU primary windows can be divided into 256 subwindows, and each
+subwindow can have its own address mapping ("guest physical" to "true
+physical"). However, each subwindow has to have the same alignment, which
+means they cannot be located at just any address. Because of these
+restrictions, it is usually impossible to create a 4KB subwindow that
+covers MSIIR where it's normally located.
+
+Therefore, the hypervisor has to create a subwindow inside the same
+primary window used for memory, but mapped to the MSIR block (where MSIIR
+lives). The first subwindow after the end of guest memory is used for
+this. The address specified in the msi-address-64 property is the PCI
+address of MSIIR. The hypervisor configures the PAMU to map that address to
+the true physical address of MSIIR.