Merge branch 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal fixes from Zhang Rui: - Fix cpu_cooling to have separate thermal_cooling_device_ops structures for cpus with and without power model, to avoid NULL dereference in cpufreq_state2power. From Brendan Jackman. - Fix a possible NULL dereference in imx_thermal driver. From Corentin LABBE. - Another two trivial fixes, one typo fix and one deleting module owner. From Caesar Wang and Markus Elfring. * 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: thermal: imx: fix a possible NULL dereference thermal: trivial: fix the typo Thermal-INT3406: Delete owner assignment thermal: cpu_cooling: Fix NULL dereference in cpufreq_state2power
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/thermal/thermal.txt10
1 files changed, 5 insertions, 5 deletions
diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
index 41b817f7b670..88b6ea1ad290 100644
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal.txt
@@ -62,7 +62,7 @@ For more examples of cooling devices, refer to the example sections below.
Required properties:
- #cooling-cells: Used to provide cooling device specific information
Type: unsigned while referring to it. Must be at least 2, in order
- Size: one cell to specify minimum and maximum cooling state used
+ Size: one cell to specify minimum and maximum cooling state used
in the reference. The first cell is the minimum
cooling state requested and the second cell is
the maximum cooling state requested in the reference.
@@ -119,7 +119,7 @@ Required properties:
Optional property:
- contribution: The cooling contribution to the thermal zone of the
Type: unsigned referred cooling device at the referred trip point.
- Size: one cell The contribution is a ratio of the sum
+ Size: one cell The contribution is a ratio of the sum
of all cooling contributions within a thermal zone.
Note: Using the THERMAL_NO_LIMIT (-1UL) constant in the cooling-device phandle
@@ -145,7 +145,7 @@ Required properties:
Size: one cell
- thermal-sensors: A list of thermal sensor phandles and sensor specifier
- Type: list of used while monitoring the thermal zone.
+ Type: list of used while monitoring the thermal zone.
phandles + sensor
specifier
@@ -473,7 +473,7 @@ thermal-zones {
<&adc>; /* pcb north */
/* hotspot = 100 * bandgap - 120 * adc + 484 */
- coefficients = <100 -120 484>;
+ coefficients = <100 -120 484>;
trips {
...
@@ -502,7 +502,7 @@ from the ADC sensor. The binding would be then:
thermal-sensors = <&adc>;
/* hotspot = 1 * adc + 6000 */
- coefficients = <1 6000>;
+ coefficients = <1 6000>;
(d) - Board thermal