summaryrefslogtreecommitdiffstats
path: root/drivers/hwmon/lm83.c
diff options
context:
space:
mode:
authorJean Delvare <khali@linux-fr.org>2007-06-09 16:11:16 +0200
committerMark M. Hoffman <mhoffman@lightlink.com>2007-07-19 20:22:12 +0200
commit7817a39e65f04abe136d94a65fa26b7fe3334a1f (patch)
tree4c7170fe690a8e66e1db341e32e28e7108e46435 /drivers/hwmon/lm83.c
parenthwmon/lm90: Add support for the Maxim MAX6680/MAX6681 (diff)
downloadlinux-7817a39e65f04abe136d94a65fa26b7fe3334a1f.tar.xz
linux-7817a39e65f04abe136d94a65fa26b7fe3334a1f.zip
hwmon: Fault files naming convention
We have the following naming convention documented in Documentation/hwmon/sysfs-interface for fault files: in[0-*]_input_fault fan[1-*]_input_fault temp[1-*]_input_fault Some drivers follow this convention (lm63, lm83, lm90, smsc47m192). However some drivers omit the "input" part and create files named fan1_fault (pc87427) or temp1_fault (dme1737). And the new "generic" libsensors follows this second (non-standard) convention, so it fails to report fault conditions for drivers which follow the standard. We want a single naming scheme, and everyone seems to prefer the shorter variant, so let's go for it. Signed-off-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'drivers/hwmon/lm83.c')
-rw-r--r--drivers/hwmon/lm83.c12
1 files changed, 6 insertions, 6 deletions
diff --git a/drivers/hwmon/lm83.c b/drivers/hwmon/lm83.c
index feb87b41e986..654c0f73464d 100644
--- a/drivers/hwmon/lm83.c
+++ b/drivers/hwmon/lm83.c
@@ -223,14 +223,14 @@ static SENSOR_DEVICE_ATTR(temp4_crit, S_IRUGO, show_temp, NULL, 8);
/* Individual alarm files */
static SENSOR_DEVICE_ATTR(temp1_crit_alarm, S_IRUGO, show_alarm, NULL, 0);
static SENSOR_DEVICE_ATTR(temp3_crit_alarm, S_IRUGO, show_alarm, NULL, 1);
-static SENSOR_DEVICE_ATTR(temp3_input_fault, S_IRUGO, show_alarm, NULL, 2);
+static SENSOR_DEVICE_ATTR(temp3_fault, S_IRUGO, show_alarm, NULL, 2);
static SENSOR_DEVICE_ATTR(temp3_max_alarm, S_IRUGO, show_alarm, NULL, 4);
static SENSOR_DEVICE_ATTR(temp1_max_alarm, S_IRUGO, show_alarm, NULL, 6);
static SENSOR_DEVICE_ATTR(temp2_crit_alarm, S_IRUGO, show_alarm, NULL, 8);
static SENSOR_DEVICE_ATTR(temp4_crit_alarm, S_IRUGO, show_alarm, NULL, 9);
-static SENSOR_DEVICE_ATTR(temp4_input_fault, S_IRUGO, show_alarm, NULL, 10);
+static SENSOR_DEVICE_ATTR(temp4_fault, S_IRUGO, show_alarm, NULL, 10);
static SENSOR_DEVICE_ATTR(temp4_max_alarm, S_IRUGO, show_alarm, NULL, 12);
-static SENSOR_DEVICE_ATTR(temp2_input_fault, S_IRUGO, show_alarm, NULL, 13);
+static SENSOR_DEVICE_ATTR(temp2_fault, S_IRUGO, show_alarm, NULL, 13);
static SENSOR_DEVICE_ATTR(temp2_max_alarm, S_IRUGO, show_alarm, NULL, 15);
/* Raw alarm file for compatibility */
static DEVICE_ATTR(alarms, S_IRUGO, show_alarms, NULL);
@@ -245,7 +245,7 @@ static struct attribute *lm83_attributes[] = {
&sensor_dev_attr_temp1_crit_alarm.dev_attr.attr,
&sensor_dev_attr_temp3_crit_alarm.dev_attr.attr,
- &sensor_dev_attr_temp3_input_fault.dev_attr.attr,
+ &sensor_dev_attr_temp3_fault.dev_attr.attr,
&sensor_dev_attr_temp3_max_alarm.dev_attr.attr,
&sensor_dev_attr_temp1_max_alarm.dev_attr.attr,
&dev_attr_alarms.attr,
@@ -266,9 +266,9 @@ static struct attribute *lm83_attributes_opt[] = {
&sensor_dev_attr_temp2_crit_alarm.dev_attr.attr,
&sensor_dev_attr_temp4_crit_alarm.dev_attr.attr,
- &sensor_dev_attr_temp4_input_fault.dev_attr.attr,
+ &sensor_dev_attr_temp4_fault.dev_attr.attr,
&sensor_dev_attr_temp4_max_alarm.dev_attr.attr,
- &sensor_dev_attr_temp2_input_fault.dev_attr.attr,
+ &sensor_dev_attr_temp2_fault.dev_attr.attr,
&sensor_dev_attr_temp2_max_alarm.dev_attr.attr,
NULL
};