1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
|
.\" -*- nroff -*-
.\" Copyright Neil Brown and others.
.\" This program is free software; you can redistribute it and/or modify
.\" it under the terms of the GNU General Public License as published by
.\" the Free Software Foundation; either version 2 of the License, or
.\" (at your option) any later version.
.\" See file COPYING in distribution for details.
.TH MDADM 8 "" v4.1-rc1
.SH NAME
mdadm \- manage MD devices
.I aka
Linux Software RAID
.SH SYNOPSIS
.BI mdadm " [mode] <raiddevice> [options] <component-devices>"
.SH DESCRIPTION
RAID devices are virtual devices created from two or more
real block devices. This allows multiple devices (typically disk
drives or partitions thereof) to be combined into a single device to
hold (for example) a single filesystem.
Some RAID levels include redundancy and so can survive some degree of
device failure.
Linux Software RAID devices are implemented through the md (Multiple
Devices) device driver.
Currently, Linux supports
.B LINEAR
md devices,
.B RAID0
(striping),
.B RAID1
(mirroring),
.BR RAID4 ,
.BR RAID5 ,
.BR RAID6 ,
.BR RAID10 ,
.BR MULTIPATH ,
.BR FAULTY ,
and
.BR CONTAINER .
.B MULTIPATH
is not a Software RAID mechanism, but does involve
multiple devices:
each device is a path to one common physical storage device.
New installations should not use md/multipath as it is not well
supported and has no ongoing development. Use the Device Mapper based
multipath-tools instead.
.B FAULTY
is also not true RAID, and it only involves one device. It
provides a layer over a true device that can be used to inject faults.
.B CONTAINER
is different again. A
.B CONTAINER
is a collection of devices that are
managed as a set. This is similar to the set of devices connected to
a hardware RAID controller. The set of devices may contain a number
of different RAID arrays each utilising some (or all) of the blocks from a
number of the devices in the set. For example, two devices in a 5-device set
might form a RAID1 using the whole devices. The remaining three might
have a RAID5 over the first half of each device, and a RAID0 over the
second half.
With a
.BR CONTAINER ,
there is one set of metadata that describes all of
the arrays in the container. So when
.I mdadm
creates a
.B CONTAINER
device, the device just represents the metadata. Other normal arrays (RAID1
etc) can be created inside the container.
.SH MODES
mdadm has several major modes of operation:
.TP
.B Assemble
Assemble the components of a previously created
array into an active array. Components can be explicitly given
or can be searched for.
.I mdadm
checks that the components
do form a bona fide array, and can, on request, fiddle superblock
information so as to assemble a faulty array.
.TP
.B Build
Build an array that doesn't have per-device metadata (superblocks). For these
sorts of arrays,
.I mdadm
cannot differentiate between initial creation and subsequent assembly
of an array. It also cannot perform any checks that appropriate
components have been requested. Because of this, the
.B Build
mode should only be used together with a complete understanding of
what you are doing.
.TP
.B Create
Create a new array with per-device metadata (superblocks).
Appropriate metadata is written to each device, and then the array
comprising those devices is activated. A 'resync' process is started
to make sure that the array is consistent (e.g. both sides of a mirror
contain the same data) but the content of the device is left otherwise
untouched.
The array can be used as soon as it has been created. There is no
need to wait for the initial resync to finish.
.TP
.B "Follow or Monitor"
Monitor one or more md devices and act on any state changes. This is
only meaningful for RAID1, 4, 5, 6, 10 or multipath arrays, as
only these have interesting state. RAID0 or Linear never have
missing, spare, or failed drives, so there is nothing to monitor.
.TP
.B "Grow"
Grow (or shrink) an array, or otherwise reshape it in some way.
Currently supported growth options including changing the active size
of component devices and changing the number of active devices in
Linear and RAID levels 0/1/4/5/6,
changing the RAID level between 0, 1, 5, and 6, and between 0 and 10,
changing the chunk size and layout for RAID 0,4,5,6,10 as well as adding or
removing a write-intent bitmap and changing the array's consistency policy.
.TP
.B "Incremental Assembly"
Add a single device to an appropriate array. If the addition of the
device makes the array runnable, the array will be started.
This provides a convenient interface to a
.I hot-plug
system. As each device is detected,
.I mdadm
has a chance to include it in some array as appropriate.
Optionally, when the
.I \-\-fail
flag is passed in we will remove the device from any active array
instead of adding it.
If a
.B CONTAINER
is passed to
.I mdadm
in this mode, then any arrays within that container will be assembled
and started.
.TP
.B Manage
This is for doing things to specific components of an array such as
adding new spares and removing faulty devices.
.TP
.B Misc
This is an 'everything else' mode that supports operations on active
arrays, operations on component devices such as erasing old superblocks, and
information gathering operations.
.\"This mode allows operations on independent devices such as examine MD
.\"superblocks, erasing old superblocks and stopping active arrays.
.TP
.B Auto-detect
This mode does not act on a specific device or array, but rather it
requests the Linux Kernel to activate any auto-detected arrays.
.SH OPTIONS
.SH Options for selecting a mode are:
.TP
.BR \-A ", " \-\-assemble
Assemble a pre-existing array.
.TP
.BR \-B ", " \-\-build
Build a legacy array without superblocks.
.TP
.BR \-C ", " \-\-create
Create a new array.
.TP
.BR \-F ", " \-\-follow ", " \-\-monitor
Select
.B Monitor
mode.
.TP
.BR \-G ", " \-\-grow
Change the size or shape of an active array.
.TP
.BR \-I ", " \-\-incremental
Add/remove a single device to/from an appropriate array, and possibly start the array.
.TP
.B \-\-auto-detect
Request that the kernel starts any auto-detected arrays. This can only
work if
.I md
is compiled into the kernel \(em not if it is a module.
Arrays can be auto-detected by the kernel if all the components are in
primary MS-DOS partitions with partition type
.BR FD ,
and all use v0.90 metadata.
In-kernel autodetect is not recommended for new installations. Using
.I mdadm
to detect and assemble arrays \(em possibly in an
.I initrd
\(em is substantially more flexible and should be preferred.
.P
If a device is given before any options, or if the first option is
one of
.BR \-\-add ,
.BR \-\-re\-add ,
.BR \-\-add\-spare ,
.BR \-\-fail ,
.BR \-\-remove ,
or
.BR \-\-replace ,
then the MANAGE mode is assumed.
Anything other than these will cause the
.B Misc
mode to be assumed.
.SH Options that are not mode-specific are:
.TP
.BR \-h ", " \-\-help
Display general help message or, after one of the above options, a
mode-specific help message.
.TP
.B \-\-help\-options
Display more detailed help about command line parsing and some commonly
used options.
.TP
.BR \-V ", " \-\-version
Print version information for mdadm.
.TP
.BR \-v ", " \-\-verbose
Be more verbose about what is happening. This can be used twice to be
extra-verbose.
The extra verbosity currently only affects
.B \-\-detail \-\-scan
and
.BR "\-\-examine \-\-scan" .
.TP
.BR \-q ", " \-\-quiet
Avoid printing purely informative messages. With this,
.I mdadm
will be silent unless there is something really important to report.
.TP
.BR \-f ", " \-\-force
Be more forceful about certain operations. See the various modes for
the exact meaning of this option in different contexts.
.TP
.BR \-c ", " \-\-config=
Specify the config file or directory. Default is to use
.B /etc/mdadm.conf
and
.BR /etc/mdadm.conf.d ,
or if those are missing then
.B /etc/mdadm/mdadm.conf
and
.BR /etc/mdadm/mdadm.conf.d .
If the config file given is
.B "partitions"
then nothing will be read, but
.I mdadm
will act as though the config file contained exactly
.br
.B " DEVICE partitions containers"
.br
and will read
.B /proc/partitions
to find a list of devices to scan, and
.B /proc/mdstat
to find a list of containers to examine.
If the word
.B "none"
is given for the config file, then
.I mdadm
will act as though the config file were empty.
If the name given is of a directory, then
.I mdadm
will collect all the files contained in the directory with a name ending
in
.BR .conf ,
sort them lexically, and process all of those files as config files.
.TP
.BR \-s ", " \-\-scan
Scan config file or
.B /proc/mdstat
for missing information.
In general, this option gives
.I mdadm
permission to get any missing information (like component devices,
array devices, array identities, and alert destination) from the
configuration file (see previous option);
one exception is MISC mode when using
.B \-\-detail
or
.B \-\-stop,
in which case
.B \-\-scan
says to get a list of array devices from
.BR /proc/mdstat .
.TP
.BR \-e ", " \-\-metadata=
Declare the style of RAID metadata (superblock) to be used. The
default is {DEFAULT_METADATA} for
.BR \-\-create ,
and to guess for other operations.
The default can be overridden by setting the
.B metadata
value for the
.B CREATE
keyword in
.BR mdadm.conf .
Options are:
.RS
.ie '{DEFAULT_METADATA}'0.90'
.IP "0, 0.90, default"
.el
.IP "0, 0.90"
Use the original 0.90 format superblock. This format limits arrays to
28 component devices and limits component devices of levels 1 and
greater to 2 terabytes. It is also possible for there to be confusion
about whether the superblock applies to a whole device or just the
last partition, if that partition starts on a 64K boundary.
.ie '{DEFAULT_METADATA}'0.90'
.IP "1, 1.0, 1.1, 1.2"
.el
.IP "1, 1.0, 1.1, 1.2 default"
Use the new version-1 format superblock. This has fewer restrictions.
It can easily be moved between hosts with different endian-ness, and a
recovery operation can be checkpointed and restarted. The different
sub-versions store the superblock at different locations on the
device, either at the end (for 1.0), at the start (for 1.1) or 4K from
the start (for 1.2). "1" is equivalent to "1.2" (the commonly
preferred 1.x format).
'if '{DEFAULT_METADATA}'1.2' "default" is equivalent to "1.2".
.IP ddf
Use the "Industry Standard" DDF (Disk Data Format) format defined by
SNIA.
When creating a DDF array a
.B CONTAINER
will be created, and normal arrays can be created in that container.
.IP imsm
Use the Intel(R) Matrix Storage Manager metadata format. This creates a
.B CONTAINER
which is managed in a similar manner to DDF, and is supported by an
option-rom on some platforms:
.IP
.B http://www.intel.com/design/chipsets/matrixstorage_sb.htm
.PP
.RE
.TP
.B \-\-homehost=
This will override any
.B HOMEHOST
setting in the config file and provides the identity of the host which
should be considered the home for any arrays.
When creating an array, the
.B homehost
will be recorded in the metadata. For version-1 superblocks, it will
be prefixed to the array name. For version-0.90 superblocks, part of
the SHA1 hash of the hostname will be stored in the later half of the
UUID.
When reporting information about an array, any array which is tagged
for the given homehost will be reported as such.
When using Auto-Assemble, only arrays tagged for the given homehost
will be allowed to use 'local' names (i.e. not ending in '_' followed
by a digit string). See below under
.BR "Auto Assembly" .
The special name "\fBany\fP" can be used as a wild card. If an array
is created with
.B --homehost=any
then the name "\fBany\fP" will be stored in the array and it can be
assembled in the same way on any host. If an array is assembled with
this option, then the homehost recorded on the array will be ignored.
.TP
.B \-\-prefer=
When
.I mdadm
needs to print the name for a device it normally finds the name in
.B /dev
which refers to the device and is shortest. When a path component is
given with
.B \-\-prefer
.I mdadm
will prefer a longer name if it contains that component. For example
.B \-\-prefer=by-uuid
will prefer a name in a subdirectory of
.B /dev
called
.BR by-uuid .
This functionality is currently only provided by
.B \-\-detail
and
.BR \-\-monitor .
.TP
.B \-\-home\-cluster=
specifies the cluster name for the md device. The md device can be assembled
only on the cluster which matches the name specified. If this option is not
provided, mdadm tries to detect the cluster name automatically.
.SH For create, build, or grow:
.TP
.BR \-n ", " \-\-raid\-devices=
Specify the number of active devices in the array. This, plus the
number of spare devices (see below) must equal the number of
.I component-devices
(including "\fBmissing\fP" devices)
that are listed on the command line for
.BR \-\-create .
Setting a value of 1 is probably
a mistake and so requires that
.B \-\-force
be specified first. A value of 1 will then be allowed for linear,
multipath, RAID0 and RAID1. It is never allowed for RAID4, RAID5 or RAID6.
.br
This number can only be changed using
.B \-\-grow
for RAID1, RAID4, RAID5 and RAID6 arrays, and only on kernels which provide
the necessary support.
.TP
.BR \-x ", " \-\-spare\-devices=
Specify the number of spare (eXtra) devices in the initial array.
Spares can also be added
and removed later. The number of component devices listed
on the command line must equal the number of RAID devices plus the
number of spare devices.
.TP
.BR \-z ", " \-\-size=
Amount (in Kilobytes) of space to use from each drive in RAID levels 1/4/5/6.
This must be a multiple of the chunk size, and must leave about 128Kb
of space at the end of the drive for the RAID superblock.
If this is not specified
(as it normally is not) the smallest drive (or partition) sets the
size, though if there is a variance among the drives of greater than 1%, a warning is
issued.
A suffix of 'K', 'M' or 'G' can be given to indicate Kilobytes, Megabytes or
Gigabytes respectively.
Sometimes a replacement drive can be a little smaller than the
original drives though this should be minimised by IDEMA standards.
Such a replacement drive will be rejected by
.IR md .
To guard against this it can be useful to set the initial size
slightly smaller than the smaller device with the aim that it will
still be larger than any replacement.
This value can be set with
.B \-\-grow
for RAID level 1/4/5/6 though
.B CONTAINER
based arrays such as those with IMSM metadata may not be able to
support this.
If the array was created with a size smaller than the currently
active drives, the extra space can be accessed using
.BR \-\-grow .
The size can be given as
.B max
which means to choose the largest size that fits on all current drives.
Before reducing the size of the array (with
.BR "\-\-grow \-\-size=" )
you should make sure that space isn't needed. If the device holds a
filesystem, you would need to resize the filesystem to use less space.
After reducing the array size you should check that the data stored in
the device is still available. If the device holds a filesystem, then
an 'fsck' of the filesystem is a minimum requirement. If there are
problems the array can be made bigger again with no loss with another
.B "\-\-grow \-\-size="
command.
This value cannot be used when creating a
.B CONTAINER
such as with DDF and IMSM metadata, though it perfectly valid when
creating an array inside a container.
.TP
.BR \-Z ", " \-\-array\-size=
This is only meaningful with
.B \-\-grow
and its effect is not persistent: when the array is stopped and
restarted the default array size will be restored.
Setting the array-size causes the array to appear smaller to programs
that access the data. This is particularly needed before reshaping an
array so that it will be smaller. As the reshape is not reversible,
but setting the size with
.B \-\-array-size
is, it is required that the array size is reduced as appropriate
before the number of devices in the array is reduced.
Before reducing the size of the array you should make sure that space
isn't needed. If the device holds a filesystem, you would need to
resize the filesystem to use less space.
After reducing the array size you should check that the data stored in
the device is still available. If the device holds a filesystem, then
an 'fsck' of the filesystem is a minimum requirement. If there are
problems the array can be made bigger again with no loss with another
.B "\-\-grow \-\-array\-size="
command.
A suffix of 'K', 'M' or 'G' can be given to indicate Kilobytes, Megabytes or
Gigabytes respectively.
A value of
.B max
restores the apparent size of the array to be whatever the real
amount of available space is.
Clustered arrays do not support this parameter yet.
.TP
.BR \-c ", " \-\-chunk=
Specify chunk size of kilobytes. The default when creating an
array is 512KB. To ensure compatibility with earlier versions, the
default when building an array with no persistent metadata is 64KB.
This is only meaningful for RAID0, RAID4, RAID5, RAID6, and RAID10.
RAID4, RAID5, RAID6, and RAID10 require the chunk size to be a power
of 2. In any case it must be a multiple of 4KB.
A suffix of 'K', 'M' or 'G' can be given to indicate Kilobytes, Megabytes or
Gigabytes respectively.
.TP
.BR \-\-rounding=
Specify rounding factor for a Linear array. The size of each
component will be rounded down to a multiple of this size.
This is a synonym for
.B \-\-chunk
but highlights the different meaning for Linear as compared to other
RAID levels. The default is 64K if a kernel earlier than 2.6.16 is in
use, and is 0K (i.e. no rounding) in later kernels.
.TP
.BR \-l ", " \-\-level=
Set RAID level. When used with
.BR \-\-create ,
options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
raid5, 5, raid6, 6, raid10, 10, multipath, mp, faulty, container.
Obviously some of these are synonymous.
When a
.B CONTAINER
metadata type is requested, only the
.B container
level is permitted, and it does not need to be explicitly given.
When used with
.BR \-\-build ,
only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
Can be used with
.B \-\-grow
to change the RAID level in some cases. See LEVEL CHANGES below.
.TP
.BR \-p ", " \-\-layout=
This option configures the fine details of data layout for RAID5, RAID6,
and RAID10 arrays, and controls the failure modes for
.IR faulty .
The layout of the RAID5 parity block can be one of
.BR left\-asymmetric ,
.BR left\-symmetric ,
.BR right\-asymmetric ,
.BR right\-symmetric ,
.BR la ", " ra ", " ls ", " rs .
The default is
.BR left\-symmetric .
It is also possible to cause RAID5 to use a RAID4-like layout by
choosing
.BR parity\-first ,
or
.BR parity\-last .
Finally for RAID5 there are DDF\-compatible layouts,
.BR ddf\-zero\-restart ,
.BR ddf\-N\-restart ,
and
.BR ddf\-N\-continue .
These same layouts are available for RAID6. There are also 4 layouts
that will provide an intermediate stage for converting between RAID5
and RAID6. These provide a layout which is identical to the
corresponding RAID5 layout on the first N\-1 devices, and has the 'Q'
syndrome (the second 'parity' block used by RAID6) on the last device.
These layouts are:
.BR left\-symmetric\-6 ,
.BR right\-symmetric\-6 ,
.BR left\-asymmetric\-6 ,
.BR right\-asymmetric\-6 ,
and
.BR parity\-first\-6 .
When setting the failure mode for level
.I faulty,
the options are:
.BR write\-transient ", " wt ,
.BR read\-transient ", " rt ,
.BR write\-persistent ", " wp ,
.BR read\-persistent ", " rp ,
.BR write\-all ,
.BR read\-fixable ", " rf ,
.BR clear ", " flush ", " none .
Each failure mode can be followed by a number, which is used as a period
between fault generation. Without a number, the fault is generated
once on the first relevant request. With a number, the fault will be
generated after that many requests, and will continue to be generated
every time the period elapses.
Multiple failure modes can be current simultaneously by using the
.B \-\-grow
option to set subsequent failure modes.
"clear" or "none" will remove any pending or periodic failure modes,
and "flush" will clear any persistent faults.
Finally, the layout options for RAID10 are one of 'n', 'o' or 'f' followed
by a small number. The default is 'n2'. The supported options are:
.I 'n'
signals 'near' copies. Multiple copies of one data block are at
similar offsets in different devices.
.I 'o'
signals 'offset' copies. Rather than the chunks being duplicated
within a stripe, whole stripes are duplicated but are rotated by one
device so duplicate blocks are on different devices. Thus subsequent
copies of a block are in the next drive, and are one chunk further
down.
.I 'f'
signals 'far' copies
(multiple copies have very different offsets).
See md(4) for more detail about 'near', 'offset', and 'far'.
The number is the number of copies of each datablock. 2 is normal, 3
can be useful. This number can be at most equal to the number of
devices in the array. It does not need to divide evenly into that
number (e.g. it is perfectly legal to have an 'n2' layout for an array
with an odd number of devices).
When an array is converted between RAID5 and RAID6 an intermediate
RAID6 layout is used in which the second parity block (Q) is always on
the last device. To convert a RAID5 to RAID6 and leave it in this new
layout (which does not require re-striping) use
.BR \-\-layout=preserve .
This will try to avoid any restriping.
The converse of this is
.B \-\-layout=normalise
which will change a non-standard RAID6 layout into a more standard
arrangement.
.TP
.BR \-\-parity=
same as
.B \-\-layout
(thus explaining the p of
.BR \-p ).
.TP
.BR \-b ", " \-\-bitmap=
Specify a file to store a write-intent bitmap in. The file should not
exist unless
.B \-\-force
is also given. The same file should be provided
when assembling the array. If the word
.B "internal"
is given, then the bitmap is stored with the metadata on the array,
and so is replicated on all devices. If the word
.B "none"
is given with
.B \-\-grow
mode, then any bitmap that is present is removed. If the word
.B "clustered"
is given, the array is created for a clustered environment. One bitmap
is created for each node as defined by the
.B \-\-nodes
parameter and are stored internally.
To help catch typing errors, the filename must contain at least one
slash ('/') if it is a real file (not 'internal' or 'none').
Note: external bitmaps are only known to work on ext2 and ext3.
Storing bitmap files on other filesystems may result in serious problems.
When creating an array on devices which are 100G or larger,
.I mdadm
automatically adds an internal bitmap as it will usually be
beneficial. This can be suppressed with
.B "\-\-bitmap=none"
or by selecting a different consistency policy with
.BR \-\-consistency\-policy .
.TP
.BR \-\-bitmap\-chunk=
Set the chunksize of the bitmap. Each bit corresponds to that many
Kilobytes of storage.
When using a file based bitmap, the default is to use the smallest
size that is at-least 4 and requires no more than 2^21 chunks.
When using an
.B internal
bitmap, the chunksize defaults to 64Meg, or larger if necessary to
fit the bitmap into the available space.
A suffix of 'K', 'M' or 'G' can be given to indicate Kilobytes, Megabytes or
Gigabytes respectively.
.TP
.BR \-W ", " \-\-write\-mostly
subsequent devices listed in a
.BR \-\-build ,
.BR \-\-create ,
or
.B \-\-add
command will be flagged as 'write\-mostly'. This is valid for RAID1
only and means that the 'md' driver will avoid reading from these
devices if at all possible. This can be useful if mirroring over a
slow link.
.TP
.BR \-\-write\-behind=
Specify that write-behind mode should be enabled (valid for RAID1
only). If an argument is specified, it will set the maximum number
of outstanding writes allowed. The default value is 256.
A write-intent bitmap is required in order to use write-behind
mode, and write-behind is only attempted on drives marked as
.IR write-mostly .
.TP
.BR \-\-failfast
subsequent devices listed in a
.B \-\-create
or
.B \-\-add
command will be flagged as 'failfast'. This is valid for RAID1 and
RAID10 only. IO requests to these devices will be encouraged to fail
quickly rather than cause long delays due to error handling. Also no
attempt is made to repair a read error on these devices.
If an array becomes degraded so that the 'failfast' device is the only
usable device, the 'failfast' flag will then be ignored and extended
delays will be preferred to complete failure.
The 'failfast' flag is appropriate for storage arrays which have a
low probability of true failure, but which may sometimes
cause unacceptable delays due to internal maintenance functions.
.TP
.BR \-\-assume\-clean
Tell
.I mdadm
that the array pre-existed and is known to be clean. It can be useful
when trying to recover from a major failure as you can be sure that no
data will be affected unless you actually write to the array. It can
also be used when creating a RAID1 or RAID10 if you want to avoid the
initial resync, however this practice \(em while normally safe \(em is not
recommended. Use this only if you really know what you are doing.
.IP
When the devices that will be part of a new array were filled
with zeros before creation the operator knows the array is
actually clean. If that is the case, such as after running
badblocks, this argument can be used to tell mdadm the
facts the operator knows.
.IP
When an array is resized to a larger size with
.B "\-\-grow \-\-size="
the new space is normally resynced in that same way that the whole
array is resynced at creation. From Linux version 3.0,
.B \-\-assume\-clean
can be used with that command to avoid the automatic resync.
.TP
.BR \-\-backup\-file=
This is needed when
.B \-\-grow
is used to increase the number of raid-devices in a RAID5 or RAID6 if
there are no spare devices available, or to shrink, change RAID level
or layout. See the GROW MODE section below on RAID\-DEVICES CHANGES.
The file must be stored on a separate device, not on the RAID array
being reshaped.
.TP
.B \-\-data\-offset=
Arrays with 1.x metadata can leave a gap between the start of the
device and the start of array data. This gap can be used for various
metadata. The start of data is known as the
.IR data\-offset .
Normally an appropriate data offset is computed automatically.
However it can be useful to set it explicitly such as when re-creating
an array which was originally created using a different version of
.I mdadm
which computed a different offset.
Setting the offset explicitly over-rides the default. The value given
is in Kilobytes unless a suffix of 'K', 'M' or 'G' is used to explicitly
indicate Kilobytes, Megabytes or Gigabytes respectively.
Since Linux 3.4,
.B \-\-data\-offset
can also be used with
.B --grow
for some RAID levels (initially on RAID10). This allows the
data\-offset to be changed as part of the reshape process. When the
data offset is changed, no backup file is required as the difference
in offsets is used to provide the same functionality.
When the new offset is earlier than the old offset, the number of
devices in the array cannot shrink. When it is after the old offset,
the number of devices in the array cannot increase.
When creating an array,
.B \-\-data\-offset
can be specified as
.BR variable .
In the case each member device is expected to have a offset appended
to the name, separated by a colon. This makes it possible to recreate
exactly an array which has varying data offsets (as can happen when
different versions of
.I mdadm
are used to add different devices).
.TP
.BR \-\-continue
This option is complementary to the
.B \-\-freeze-reshape
option for assembly. It is needed when
.B \-\-grow
operation is interrupted and it is not restarted automatically due to
.B \-\-freeze-reshape
usage during array assembly. This option is used together with
.BR \-G
, (
.BR \-\-grow
) command and device for a pending reshape to be continued.
All parameters required for reshape continuation will be read from array metadata.
If initial
.BR \-\-grow
command had required
.BR \-\-backup\-file=
option to be set, continuation option will require to have exactly the same
backup file given as well.
.IP
Any other parameter passed together with
.BR \-\-continue
option will be ignored.
.TP
.BR \-N ", " \-\-name=
Set a
.B name
for the array. This is currently only effective when creating an
array with a version-1 superblock, or an array in a DDF container.
The name is a simple textual string that can be used to identify array
components when assembling. If name is needed but not specified, it
is taken from the basename of the device that is being created.
e.g. when creating
.I /dev/md/home
the
.B name
will default to
.IR home .
.TP
.BR \-R ", " \-\-run
Insist that
.I mdadm
run the array, even if some of the components
appear to be active in another array or filesystem. Normally
.I mdadm
will ask for confirmation before including such components in an
array. This option causes that question to be suppressed.
.TP
.BR \-f ", " \-\-force
Insist that
.I mdadm
accept the geometry and layout specified without question. Normally
.I mdadm
will not allow creation of an array with only one device, and will try
to create a RAID5 array with one missing drive (as this makes the
initial resync work faster). With
.BR \-\-force ,
.I mdadm
will not try to be so clever.
.TP
.BR \-o ", " \-\-readonly
Start the array
.B read only
rather than read-write as normal. No writes will be allowed to the
array, and no resync, recovery, or reshape will be started. It works with
Create, Assemble, Manage and Misc mode.
.TP
.BR \-a ", " "\-\-auto{=yes,md,mdp,part,p}{NN}"
Instruct mdadm how to create the device file if needed, possibly allocating
an unused minor number. "md" causes a non-partitionable array
to be used (though since Linux 2.6.28, these array devices are in fact
partitionable). "mdp", "part" or "p" causes a partitionable array (2.6 and
later) to be used. "yes" requires the named md device to have
a 'standard' format, and the type and minor number will be determined
from this. With mdadm 3.0, device creation is normally left up to
.I udev
so this option is unlikely to be needed.
See DEVICE NAMES below.
The argument can also come immediately after
"\-a". e.g. "\-ap".
If
.B \-\-auto
is not given on the command line or in the config file, then
the default will be
.BR \-\-auto=yes .
If
.B \-\-scan
is also given, then any
.I auto=
entries in the config file will override the
.B \-\-auto
instruction given on the command line.
For partitionable arrays,
.I mdadm
will create the device file for the whole array and for the first 4
partitions. A different number of partitions can be specified at the
end of this option (e.g.
.BR \-\-auto=p7 ).
If the device name ends with a digit, the partition names add a 'p',
and a number, e.g.
.IR /dev/md/home1p3 .
If there is no trailing digit, then the partition names just have a
number added, e.g.
.IR /dev/md/scratch3 .
If the md device name is in a 'standard' format as described in DEVICE
NAMES, then it will be created, if necessary, with the appropriate
device number based on that name. If the device name is not in one of these
formats, then a unused device number will be allocated. The device
number will be considered unused if there is no active array for that
number, and there is no entry in /dev for that number and with a
non-standard name. Names that are not in 'standard' format are only
allowed in "/dev/md/".
This is meaningful with
.B \-\-create
or
.BR \-\-build .
.TP
.BR \-a ", " "\-\-add"
This option can be used in Grow mode in two cases.
If the target array is a Linear array, then
.B \-\-add
can be used to add one or more devices to the array. They
are simply catenated on to the end of the array. Once added, the
devices cannot be removed.
If the
.B \-\-raid\-disks
option is being used to increase the number of devices in an array,
then
.B \-\-add
can be used to add some extra devices to be included in the array.
In most cases this is not needed as the extra devices can be added as
spares first, and then the number of raid-disks can be changed.
However for RAID0, it is not possible to add spares. So to increase
the number of devices in a RAID0, it is necessary to set the new
number of devices, and to add the new devices, in the same command.
.TP
.BR \-\-nodes
Only works when the array is for clustered environment. It specifies
the maximum number of nodes in the cluster that will use this device
simultaneously. If not specified, this defaults to 4.
.TP
.BR \-\-write-journal
Specify journal device for the RAID-4/5/6 array. The journal device
should be a SSD with reasonable lifetime.
.TP
.BR \-\-symlinks
Auto creation of symlinks in /dev to /dev/md, option --symlinks must
be 'no' or 'yes' and work with --create and --build.
.TP
.BR \-k ", " \-\-consistency\-policy=
Specify how the array maintains consistency in case of unexpected shutdown.
Only relevant for RAID levels with redundancy.
Currently supported options are:
.RS
.TP
.B resync
Full resync is performed and all redundancy is regenerated when the array is
started after unclean shutdown.
.TP
.B bitmap
Resync assisted by a write-intent bitmap. Implicitly selected when using
.BR \-\-bitmap .
.TP
.B journal
For RAID levels 4/5/6, journal device is used to log transactions and replay
after unclean shutdown. Implicitly selected when using
.BR \-\-write\-journal .
.TP
.B ppl
For RAID5 only, Partial Parity Log is used to close the write hole and
eliminate resync. PPL is stored in the metadata region of RAID member drives,
no additional journal drive is needed.
.PP
Can be used with \-\-grow to change the consistency policy of an active array
in some cases. See CONSISTENCY POLICY CHANGES below.
.RE
.SH For assemble:
.TP
.BR \-u ", " \-\-uuid=
uuid of array to assemble. Devices which don't have this uuid are
excluded
.TP
.BR \-m ", " \-\-super\-minor=
Minor number of device that array was created for. Devices which
don't have this minor number are excluded. If you create an array as
/dev/md1, then all superblocks will contain the minor number 1, even if
the array is later assembled as /dev/md2.
Giving the literal word "dev" for
.B \-\-super\-minor
will cause
.I mdadm
to use the minor number of the md device that is being assembled.
e.g. when assembling
.BR /dev/md0 ,
.B \-\-super\-minor=dev
will look for super blocks with a minor number of 0.
.B \-\-super\-minor
is only relevant for v0.90 metadata, and should not normally be used.
Using
.B \-\-uuid
is much safer.
.TP
.BR \-N ", " \-\-name=
Specify the name of the array to assemble. This must be the name
that was specified when creating the array. It must either match
the name stored in the superblock exactly, or it must match
with the current
.I homehost
prefixed to the start of the given name.
.TP
.BR \-f ", " \-\-force
Assemble the array even if the metadata on some devices appears to be
out-of-date. If
.I mdadm
cannot find enough working devices to start the array, but can find
some devices that are recorded as having failed, then it will mark
those devices as working so that the array can be started.
An array which requires
.B \-\-force
to be started may contain data corruption. Use it carefully.
.TP
.BR \-R ", " \-\-run
Attempt to start the array even if fewer drives were given than were
present last time the array was active. Normally if not all the
expected drives are found and
.B \-\-scan
is not used, then the array will be assembled but not started.
With
.B \-\-run
an attempt will be made to start it anyway.
.TP
.B \-\-no\-degraded
This is the reverse of
.B \-\-run
in that it inhibits the startup of array unless all expected drives
are present. This is only needed with
.B \-\-scan,
and can be used if the physical connections to devices are
not as reliable as you would like.
.TP
.BR \-a ", " "\-\-auto{=no,yes,md,mdp,part}"
See this option under Create and Build options.
.TP
.BR \-b ", " \-\-bitmap=
Specify the bitmap file that was given when the array was created. If
an array has an
.B internal
bitmap, there is no need to specify this when assembling the array.
.TP
.BR \-\-backup\-file=
If
.B \-\-backup\-file
was used while reshaping an array (e.g. changing number of devices or
chunk size) and the system crashed during the critical section, then the same
.B \-\-backup\-file
must be presented to
.B \-\-assemble
to allow possibly corrupted data to be restored, and the reshape
to be completed.
.TP
.BR \-\-invalid\-backup
If the file needed for the above option is not available for any
reason an empty file can be given together with this option to
indicate that the backup file is invalid. In this case the data that
was being rearranged at the time of the crash could be irrecoverably
lost, but the rest of the array may still be recoverable. This option
should only be used as a last resort if there is no way to recover the
backup file.
.TP
.BR \-U ", " \-\-update=
Update the superblock on each device while assembling the array. The
argument given to this flag can be one of
.BR sparc2.2 ,
.BR summaries ,
.BR uuid ,
.BR name ,
.BR nodes ,
.BR homehost ,
.BR home-cluster ,
.BR resync ,
.BR byteorder ,
.BR devicesize ,
.BR no\-bitmap ,
.BR bbl ,
.BR no\-bbl ,
.BR ppl ,
.BR no\-ppl ,
.BR metadata ,
or
.BR super\-minor .
The
.B sparc2.2
option will adjust the superblock of an array what was created on a Sparc
machine running a patched 2.2 Linux kernel. This kernel got the
alignment of part of the superblock wrong. You can use the
.B "\-\-examine \-\-sparc2.2"
option to
.I mdadm
to see what effect this would have.
The
.B super\-minor
option will update the
.B "preferred minor"
field on each superblock to match the minor number of the array being
assembled.
This can be useful if
.B \-\-examine
reports a different "Preferred Minor" to
.BR \-\-detail .
In some cases this update will be performed automatically
by the kernel driver. In particular the update happens automatically
at the first write to an array with redundancy (RAID level 1 or
greater) on a 2.6 (or later) kernel.
The
.B uuid
option will change the uuid of the array. If a UUID is given with the
.B \-\-uuid
option that UUID will be used as a new UUID and will
.B NOT
be used to help identify the devices in the array.
If no
.B \-\-uuid
is given, a random UUID is chosen.
The
.B name
option will change the
.I name
of the array as stored in the superblock. This is only supported for
version-1 superblocks.
The
.B nodes
option will change the
.I nodes
of the array as stored in the bitmap superblock. This option only
works for a clustered environment.
The
.B homehost
option will change the
.I homehost
as recorded in the superblock. For version-0 superblocks, this is the
same as updating the UUID.
For version-1 superblocks, this involves updating the name.
The
.B home\-cluster
option will change the cluster name as recorded in the superblock and
bitmap. This option only works for clustered environment.
The
.B resync
option will cause the array to be marked
.I dirty
meaning that any redundancy in the array (e.g. parity for RAID5,
copies for RAID1) may be incorrect. This will cause the RAID system
to perform a "resync" pass to make sure that all redundant information
is correct.
The
.B byteorder
option allows arrays to be moved between machines with different
byte-order, such as from a big-endian machine like a Sparc or some
MIPS machines, to a little-endian x86_64 machine.
When assembling such an array for the first time after a move, giving
.B "\-\-update=byteorder"
will cause
.I mdadm
to expect superblocks to have their byteorder reversed, and will
correct that order before assembling the array. This is only valid
with original (Version 0.90) superblocks.
The
.B summaries
option will correct the summaries in the superblock. That is the
counts of total, working, active, failed, and spare devices.
The
.B devicesize
option will rarely be of use. It applies to version 1.1 and 1.2 metadata
only (where the metadata is at the start of the device) and is only
useful when the component device has changed size (typically become
larger). The version 1 metadata records the amount of the device that
can be used to store data, so if a device in a version 1.1 or 1.2
array becomes larger, the metadata will still be visible, but the
extra space will not. In this case it might be useful to assemble the
array with
.BR \-\-update=devicesize .
This will cause
.I mdadm
to determine the maximum usable amount of space on each device and
update the relevant field in the metadata.
The
.B metadata
option only works on v0.90 metadata arrays and will convert them to
v1.0 metadata. The array must not be dirty (i.e. it must not need a
sync) and it must not have a write-intent bitmap.
The old metadata will remain on the devices, but will appear older
than the new metadata and so will usually be ignored. The old metadata
(or indeed the new metadata) can be removed by giving the appropriate
.B \-\-metadata=
option to
.BR \-\-zero\-superblock .
The
.B no\-bitmap
option can be used when an array has an internal bitmap which is
corrupt in some way so that assembling the array normally fails. It
will cause any internal bitmap to be ignored.
The
.B bbl
option will reserve space in each device for a bad block list. This
will be 4K in size and positioned near the end of any free space
between the superblock and the data.
The
.B no\-bbl
option will cause any reservation of space for a bad block list to be
removed. If the bad block list contains entries, this will fail, as
removing the list could cause data corruption.
The
.B ppl
option will enable PPL for a RAID5 array and reserve space for PPL on each
device. There must be enough free space between the data and superblock and a
write-intent bitmap or journal must not be used.
The
.B no\-ppl
option will disable PPL in the superblock.
.TP
.BR \-\-freeze\-reshape
Option is intended to be used in start-up scripts during initrd boot phase.
When array under reshape is assembled during initrd phase, this option
stops reshape after reshape critical section is being restored. This happens
before file system pivot operation and avoids loss of file system context.
Losing file system context would cause reshape to be broken.
Reshape can be continued later using the
.B \-\-continue
option for the grow command.
.TP
.BR \-\-symlinks
See this option under Create and Build options.
.SH For Manage mode:
.TP
.BR \-t ", " \-\-test
Unless a more serious error occurred,
.I mdadm
will exit with a status of 2 if no changes were made to the array and
0 if at least one change was made.
This can be useful when an indirect specifier such as
.BR missing ,
.B detached
or
.B faulty
is used in requesting an operation on the array.
.B \-\-test
will report failure if these specifiers didn't find any match.
.TP
.BR \-a ", " \-\-add
hot-add listed devices.
If a device appears to have recently been part of the array
(possibly it failed or was removed) the device is re\-added as described
in the next point.
If that fails or the device was never part of the array, the device is
added as a hot-spare.
If the array is degraded, it will immediately start to rebuild data
onto that spare.
Note that this and the following options are only meaningful on array
with redundancy. They don't apply to RAID0 or Linear.
.TP
.BR \-\-re\-add
re\-add a device that was previously removed from an array.
If the metadata on the device reports that it is a member of the
array, and the slot that it used is still vacant, then the device will
be added back to the array in the same position. This will normally
cause the data for that device to be recovered. However based on the
event count on the device, the recovery may only require sections that
are flagged a write-intent bitmap to be recovered or may not require
any recovery at all.
When used on an array that has no metadata (i.e. it was built with
.BR \-\-build)
it will be assumed that bitmap-based recovery is enough to make the
device fully consistent with the array.
When used with v1.x metadata,
.B \-\-re\-add
can be accompanied by
.BR \-\-update=devicesize ,
.BR \-\-update=bbl ", or"
.BR \-\-update=no\-bbl .
See the description of these option when used in Assemble mode for an
explanation of their use.
If the device name given is
.B missing
then
.I mdadm
will try to find any device that looks like it should be
part of the array but isn't and will try to re\-add all such devices.
If the device name given is
.B faulty
then
.I mdadm
will find all devices in the array that are marked
.BR faulty ,
remove them and attempt to immediately re\-add them. This can be
useful if you are certain that the reason for failure has been
resolved.
.TP
.B \-\-add\-spare
Add a device as a spare. This is similar to
.B \-\-add
except that it does not attempt
.B \-\-re\-add
first. The device will be added as a spare even if it looks like it
could be an recent member of the array.
.TP
.BR \-r ", " \-\-remove
remove listed devices. They must not be active. i.e. they should
be failed or spare devices.
As well as the name of a device file
(e.g.
.BR /dev/sda1 )
the words
.BR failed ,
.B detached
and names like
.B set-A
can be given to
.BR \-\-remove .
The first causes all failed device to be removed. The second causes
any device which is no longer connected to the system (i.e an 'open'
returns
.BR ENXIO )
to be removed.
The third will remove a set as describe below under
.BR \-\-fail .
.TP
.BR \-f ", " \-\-fail
Mark listed devices as faulty.
As well as the name of a device file, the word
.B detached
or a set name like
.B set\-A
can be given. The former will cause any device that has been detached from
the system to be marked as failed. It can then be removed.
For RAID10 arrays where the number of copies evenly divides the number
of devices, the devices can be conceptually divided into sets where
each set contains a single complete copy of the data on the array.
Sometimes a RAID10 array will be configured so that these sets are on
separate controllers. In this case all the devices in one set can be
failed by giving a name like
.B set\-A
or
.B set\-B
to
.BR \-\-fail .
The appropriate set names are reported by
.BR \-\-detail .
.TP
.BR \-\-set\-faulty
same as
.BR \-\-fail .
.TP
.B \-\-replace
Mark listed devices as requiring replacement. As soon as a spare is
available, it will be rebuilt and will replace the marked device.
This is similar to marking a device as faulty, but the device remains
in service during the recovery process to increase resilience against
multiple failures. When the replacement process finishes, the
replaced device will be marked as faulty.
.TP
.B \-\-with
This can follow a list of
.B \-\-replace
devices. The devices listed after
.B \-\-with
will be preferentially used to replace the devices listed after
.BR \-\-replace .
These device must already be spare devices in the array.
.TP
.BR \-\-write\-mostly
Subsequent devices that are added or re\-added will have the 'write-mostly'
flag set. This is only valid for RAID1 and means that the 'md' driver
will avoid reading from these devices if possible.
.TP
.BR \-\-readwrite
Subsequent devices that are added or re\-added will have the 'write-mostly'
flag cleared.
.TP
.BR \-\-cluster\-confirm
Confirm the existence of the device. This is issued in response to an \-\-add
request by a node in a cluster. When a node adds a device it sends a message
to all nodes in the cluster to look for a device with a UUID. This translates
to a udev notification with the UUID of the device to be added and the slot
number. The receiving node must acknowledge this message
with \-\-cluster\-confirm. Valid arguments are <slot>:<devicename> in case
the device is found or <slot>:missing in case the device is not found.
.TP
.BR \-\-add-journal
Add journal to an existing array, or recreate journal for RAID-4/5/6 array
that lost a journal device. To avoid interrupting on-going write opertions,
.B \-\-add-journal
only works for array in Read-Only state.
.TP
.BR \-\-failfast
Subsequent devices that are added or re\-added will have
the 'failfast' flag set. This is only valid for RAID1 and RAID10 and
means that the 'md' driver will avoid long timeouts on error handling
where possible.
.TP
.BR \-\-nofailfast
Subsequent devices that are re\-added will be re\-added without
the 'failfast' flag set.
.P
Each of these options requires that the first device listed is the array
to be acted upon, and the remainder are component devices to be added,
removed, marked as faulty, etc. Several different operations can be
specified for different devices, e.g.
.in +5
mdadm /dev/md0 \-\-add /dev/sda1 \-\-fail /dev/sdb1 \-\-remove /dev/sdb1
.in -5
Each operation applies to all devices listed until the next
operation.
If an array is using a write-intent bitmap, then devices which have
been removed can be re\-added in a way that avoids a full
reconstruction but instead just updates the blocks that have changed
since the device was removed. For arrays with persistent metadata
(superblocks) this is done automatically. For arrays created with
.B \-\-build
mdadm needs to be told that this device we removed recently with
.BR \-\-re\-add .
Devices can only be removed from an array if they are not in active
use, i.e. that must be spares or failed devices. To remove an active
device, it must first be marked as
.B faulty.
.SH For Misc mode:
.TP
.BR \-Q ", " \-\-query
Examine a device to see
(1) if it is an md device and (2) if it is a component of an md
array.
Information about what is discovered is presented.
.TP
.BR \-D ", " \-\-detail
Print details of one or more md devices.
.TP
.BR \-\-detail\-platform
Print details of the platform's RAID capabilities (firmware / hardware
topology) for a given metadata format. If used without argument, mdadm
will scan all controllers looking for their capabilities. Otherwise, mdadm
will only look at the controller specified by the argument in form of an
absolute filepath or a link, e.g.
.IR /sys/devices/pci0000:00/0000:00:1f.2 .
.TP
.BR \-Y ", " \-\-export
When used with
.BR \-\-detail ,
.BR \-\-detail-platform ,
.BR \-\-examine ,
or
.B \-\-incremental
output will be formatted as
.B key=value
pairs for easy import into the environment.
With
.B \-\-incremental
The value
.B MD_STARTED
indicates whether an array was started
.RB ( yes )
or not, which may include a reason
.RB ( unsafe ", " nothing ", " no ).
Also the value
.B MD_FOREIGN
indicates if the array is expected on this host
.RB ( no ),
or seems to be from elsewhere
.RB ( yes ).
.TP
.BR \-E ", " \-\-examine
Print contents of the metadata stored on the named device(s).
Note the contrast between
.B \-\-examine
and
.BR \-\-detail .
.B \-\-examine
applies to devices which are components of an array, while
.B \-\-detail
applies to a whole array which is currently active.
.TP
.B \-\-sparc2.2
If an array was created on a SPARC machine with a 2.2 Linux kernel
patched with RAID support, the superblock will have been created
incorrectly, or at least incompatibly with 2.4 and later kernels.
Using the
.B \-\-sparc2.2
flag with
.B \-\-examine
will fix the superblock before displaying it. If this appears to do
the right thing, then the array can be successfully assembled using
.BR "\-\-assemble \-\-update=sparc2.2" .
.TP
.BR \-X ", " \-\-examine\-bitmap
Report information about a bitmap file.
The argument is either an external bitmap file or an array component
in case of an internal bitmap. Note that running this on an array
device (e.g.
.BR /dev/md0 )
does not report the bitmap for that array.
.TP
.B \-\-examine\-badblocks
List the bad-blocks recorded for the device, if a bad-blocks list has
been configured. Currently only
.B 1.x
metadata supports bad-blocks lists.
.TP
.BI \-\-dump= directory
.TP
.BI \-\-restore= directory
Save metadata from lists devices, or restore metadata to listed devices.
.TP
.BR \-R ", " \-\-run
start a partially assembled array. If
.B \-\-assemble
did not find enough devices to fully start the array, it might leaving
it partially assembled. If you wish, you can then use
.B \-\-run
to start the array in degraded mode.
.TP
.BR \-S ", " \-\-stop
deactivate array, releasing all resources.
.TP
.BR \-o ", " \-\-readonly
mark array as readonly.
.TP
.BR \-w ", " \-\-readwrite
mark array as readwrite.
.TP
.B \-\-zero\-superblock
If the device contains a valid md superblock, the block is
overwritten with zeros. With
.B \-\-force
the block where the superblock would be is overwritten even if it
doesn't appear to be valid.
.B Note:
Be careful to call \-\-zero\-superblock with clustered raid, make sure
array isn't used or assembled in other cluster node before execute it.
.TP
.B \-\-kill\-subarray=
If the device is a container and the argument to \-\-kill\-subarray
specifies an inactive subarray in the container, then the subarray is
deleted. Deleting all subarrays will leave an 'empty-container' or
spare superblock on the drives. See
.B \-\-zero\-superblock
for completely
removing a superblock. Note that some formats depend on the subarray
index for generating a UUID, this command will fail if it would change
the UUID of an active subarray.
.TP
.B \-\-update\-subarray=
If the device is a container and the argument to \-\-update\-subarray
specifies a subarray in the container, then attempt to update the given
superblock field in the subarray. See below in
.B MISC MODE
for details.
.TP
.BR \-t ", " \-\-test
When used with
.BR \-\-detail ,
the exit status of
.I mdadm
is set to reflect the status of the device. See below in
.B MISC MODE
for details.
.TP
.BR \-W ", " \-\-wait
For each md device given, wait for any resync, recovery, or reshape
activity to finish before returning.
.I mdadm
will return with success if it actually waited for every device
listed, otherwise it will return failure.
.TP
.BR \-\-wait\-clean
For each md device given, or each device in /proc/mdstat if
.B \-\-scan
is given, arrange for the array to be marked clean as soon as possible.
.I mdadm
will return with success if the array uses external metadata and we
successfully waited. For native arrays this returns immediately as the
kernel handles dirty-clean transitions at shutdown. No action is taken
if safe-mode handling is disabled.
.TP
.B \-\-action=
Set the "sync_action" for all md devices given to one of
.BR idle ,
.BR frozen ,
.BR check ,
.BR repair .
Setting to
.B idle
will abort any currently running action though some actions will
automatically restart.
Setting to
.B frozen
will abort any current action and ensure no other action starts
automatically.
Details of
.B check
and
.B repair
can be found it
.IR md (4)
under
.BR "SCRUBBING AND MISMATCHES" .
.SH For Incremental Assembly mode:
.TP
.BR \-\-rebuild\-map ", " \-r
Rebuild the map file
.RB ( {MAP_PATH} )
that
.I mdadm
uses to help track which arrays are currently being assembled.
.TP
.BR \-\-run ", " \-R
Run any array assembled as soon as a minimal number of devices are
available, rather than waiting until all expected devices are present.
.TP
.BR \-\-scan ", " \-s
Only meaningful with
.B \-R
this will scan the
.B map
file for arrays that are being incrementally assembled and will try to
start any that are not already started. If any such array is listed
in
.B mdadm.conf
as requiring an external bitmap, that bitmap will be attached first.
.TP
.BR \-\-fail ", " \-f
This allows the hot-plug system to remove devices that have fully disappeared
from the kernel. It will first fail and then remove the device from any
array it belongs to.
The device name given should be a kernel device name such as "sda",
not a name in
.IR /dev .
.TP
.BR \-\-path=
Only used with \-\-fail. The 'path' given will be recorded so that if
a new device appears at the same location it can be automatically
added to the same array. This allows the failed device to be
automatically replaced by a new device without metadata if it appears
at specified path. This option is normally only set by a
.I udev
script.
.SH For Monitor mode:
.TP
.BR \-m ", " \-\-mail
Give a mail address to send alerts to.
.TP
.BR \-p ", " \-\-program ", " \-\-alert
Give a program to be run whenever an event is detected.
.TP
.BR \-y ", " \-\-syslog
Cause all events to be reported through 'syslog'. The messages have
facility of 'daemon' and varying priorities.
.TP
.BR \-d ", " \-\-delay
Give a delay in seconds.
.I mdadm
polls the md arrays and then waits this many seconds before polling
again. The default is 60 seconds. Since 2.6.16, there is no need to
reduce this as the kernel alerts
.I mdadm
immediately when there is any change.
.TP
.BR \-r ", " \-\-increment
Give a percentage increment.
.I mdadm
will generate RebuildNN events with the given percentage increment.
.TP
.BR \-f ", " \-\-daemonise
Tell
.I mdadm
to run as a background daemon if it decides to monitor anything. This
causes it to fork and run in the child, and to disconnect from the
terminal. The process id of the child is written to stdout.
This is useful with
.B \-\-scan
which will only continue monitoring if a mail address or alert program
is found in the config file.
.TP
.BR \-i ", " \-\-pid\-file
When
.I mdadm
is running in daemon mode, write the pid of the daemon process to
the specified file, instead of printing it on standard output.
.TP
.BR \-1 ", " \-\-oneshot
Check arrays only once. This will generate
.B NewArray
events and more significantly
.B DegradedArray
and
.B SparesMissing
events. Running
.in +5
.B " mdadm \-\-monitor \-\-scan \-1"
.in -5
from a cron script will ensure regular notification of any degraded arrays.
.TP
.BR \-t ", " \-\-test
Generate a
.B TestMessage
alert for every array found at startup. This alert gets mailed and
passed to the alert program. This can be used for testing that alert
message do get through successfully.
.TP
.BR \-\-no\-sharing
This inhibits the functionality for moving spares between arrays.
Only one monitoring process started with
.B \-\-scan
but without this flag is allowed, otherwise the two could interfere
with each other.
.SH ASSEMBLE MODE
.HP 12
Usage:
.B mdadm \-\-assemble
.I md-device options-and-component-devices...
.HP 12
Usage:
.B mdadm \-\-assemble \-\-scan
.I md-devices-and-options...
.HP 12
Usage:
.B mdadm \-\-assemble \-\-scan
.I options...
.PP
This usage assembles one or more RAID arrays from pre-existing components.
For each array, mdadm needs to know the md device, the identity of the
array, and a number of component-devices. These can be found in a number of ways.
In the first usage example (without the
.BR \-\-scan )
the first device given is the md device.
In the second usage example, all devices listed are treated as md
devices and assembly is attempted.
In the third (where no devices are listed) all md devices that are
listed in the configuration file are assembled. If no arrays are
described by the configuration file, then any arrays that
can be found on unused devices will be assembled.
If precisely one device is listed, but
.B \-\-scan
is not given, then
.I mdadm
acts as though
.B \-\-scan
was given and identity information is extracted from the configuration file.
The identity can be given with the
.B \-\-uuid
option, the
.B \-\-name
option, or the
.B \-\-super\-minor
option, will be taken from the md-device record in the config file, or
will be taken from the super block of the first component-device
listed on the command line.
Devices can be given on the
.B \-\-assemble
command line or in the config file. Only devices which have an md
superblock which contains the right identity will be considered for
any array.
The config file is only used if explicitly named with
.B \-\-config
or requested with (a possibly implicit)
.BR \-\-scan .
In the later case,
.B /etc/mdadm.conf
or
.B /etc/mdadm/mdadm.conf
is used.
If
.B \-\-scan
is not given, then the config file will only be used to find the
identity of md arrays.
Normally the array will be started after it is assembled. However if
.B \-\-scan
is not given and not all expected drives were listed, then the array
is not started (to guard against usage errors). To insist that the
array be started in this case (as may work for RAID1, 4, 5, 6, or 10),
give the
.B \-\-run
flag.
If
.I udev
is active,
.I mdadm
does not create any entries in
.B /dev
but leaves that to
.IR udev .
It does record information in
.B {MAP_PATH}
which will allow
.I udev
to choose the correct name.
If
.I mdadm
detects that udev is not configured, it will create the devices in
.B /dev
itself.
In Linux kernels prior to version 2.6.28 there were two distinctly
different types of md devices that could be created: one that could be
partitioned using standard partitioning tools and one that could not.
Since 2.6.28 that distinction is no longer relevant as both type of
devices can be partitioned.
.I mdadm
will normally create the type that originally could not be partitioned
as it has a well defined major number (9).
Prior to 2.6.28, it is important that mdadm chooses the correct type
of array device to use. This can be controlled with the
.B \-\-auto
option. In particular, a value of "mdp" or "part" or "p" tells mdadm
to use a partitionable device rather than the default.
In the no-udev case, the value given to
.B \-\-auto
can be suffixed by a number. This tells
.I mdadm
to create that number of partition devices rather than the default of 4.
The value given to
.B \-\-auto
can also be given in the configuration file as a word starting
.B auto=
on the ARRAY line for the relevant array.
.SS Auto Assembly
When
.B \-\-assemble
is used with
.B \-\-scan
and no devices are listed,
.I mdadm
will first attempt to assemble all the arrays listed in the config
file.
If no arrays are listed in the config (other than those marked
.BR <ignore> )
it will look through the available devices for possible arrays and
will try to assemble anything that it finds. Arrays which are tagged
as belonging to the given homehost will be assembled and started
normally. Arrays which do not obviously belong to this host are given
names that are expected not to conflict with anything local, and are
started "read-auto" so that nothing is written to any device until the
array is written to. i.e. automatic resync etc is delayed.
If
.I mdadm
finds a consistent set of devices that look like they should comprise
an array, and if the superblock is tagged as belonging to the given
home host, it will automatically choose a device name and try to
assemble the array. If the array uses version-0.90 metadata, then the
.B minor
number as recorded in the superblock is used to create a name in
.B /dev/md/
so for example
.BR /dev/md/3 .
If the array uses version-1 metadata, then the
.B name
from the superblock is used to similarly create a name in
.B /dev/md/
(the name will have any 'host' prefix stripped first).
This behaviour can be modified by the
.I AUTO
line in the
.I mdadm.conf
configuration file. This line can indicate that specific metadata
type should, or should not, be automatically assembled. If an array
is found which is not listed in
.I mdadm.conf
and has a metadata format that is denied by the
.I AUTO
line, then it will not be assembled.
The
.I AUTO
line can also request that all arrays identified as being for this
homehost should be assembled regardless of their metadata type.
See
.IR mdadm.conf (5)
for further details.
Note: Auto assembly cannot be used for assembling and activating some
arrays which are undergoing reshape. In particular as the
.B backup\-file
cannot be given, any reshape which requires a backup-file to continue
cannot be started by auto assembly. An array which is growing to more
devices and has passed the critical section can be assembled using
auto-assembly.
.SH BUILD MODE
.HP 12
Usage:
.B mdadm \-\-build
.I md-device
.BI \-\-chunk= X
.BI \-\-level= Y
.BI \-\-raid\-devices= Z
.I devices
.PP
This usage is similar to
.BR \-\-create .
The difference is that it creates an array without a superblock. With
these arrays there is no difference between initially creating the array and
subsequently assembling the array, except that hopefully there is useful
data there in the second case.
The level may raid0, linear, raid1, raid10, multipath, or faulty, or
one of their synonyms. All devices must be listed and the array will
be started once complete. It will often be appropriate to use
.B \-\-assume\-clean
with levels raid1 or raid10.
.SH CREATE MODE
.HP 12
Usage:
.B mdadm \-\-create
.I md-device
.BI \-\-chunk= X
.BI \-\-level= Y
.br
.BI \-\-raid\-devices= Z
.I devices
.PP
This usage will initialise a new md array, associate some devices with
it, and activate the array.
The named device will normally not exist when
.I "mdadm \-\-create"
is run, but will be created by
.I udev
once the array becomes active.
As devices are added, they are checked to see if they contain RAID
superblocks or filesystems. They are also checked to see if the variance in
device size exceeds 1%.
If any discrepancy is found, the array will not automatically be run, though
the presence of a
.B \-\-run
can override this caution.
To create a "degraded" array in which some devices are missing, simply
give the word "\fBmissing\fP"
in place of a device name. This will cause
.I mdadm
to leave the corresponding slot in the array empty.
For a RAID4 or RAID5 array at most one slot can be
"\fBmissing\fP"; for a RAID6 array at most two slots.
For a RAID1 array, only one real device needs to be given. All of the
others can be
"\fBmissing\fP".
When creating a RAID5 array,
.I mdadm
will automatically create a degraded array with an extra spare drive.
This is because building the spare into a degraded array is in general
faster than resyncing the parity on a non-degraded, but not clean,
array. This feature can be overridden with the
.B \-\-force
option.
When creating an array with version-1 metadata a name for the array is
required.
If this is not given with the
.B \-\-name
option,
.I mdadm
will choose a name based on the last component of the name of the
device being created. So if
.B /dev/md3
is being created, then the name
.B 3
will be chosen.
If
.B /dev/md/home
is being created, then the name
.B home
will be used.
When creating a partition based array, using
.I mdadm
with version-1.x metadata, the partition type should be set to
.B 0xDA
(non fs-data). This type selection allows for greater precision since
using any other [RAID auto-detect (0xFD) or a GNU/Linux partition (0x83)],
might create problems in the event of array recovery through a live cdrom.
A new array will normally get a randomly assigned 128bit UUID which is
very likely to be unique. If you have a specific need, you can choose
a UUID for the array by giving the
.B \-\-uuid=
option. Be warned that creating two arrays with the same UUID is a
recipe for disaster. Also, using
.B \-\-uuid=
when creating a v0.90 array will silently override any
.B \-\-homehost=
setting.
.\"If the
.\".B \-\-size
.\"option is given, it is not necessary to list any component-devices in this command.
.\"They can be added later, before a
.\".B \-\-run.
.\"If no
.\".B \-\-size
.\"is given, the apparent size of the smallest drive given is used.
If the array type supports a write-intent bitmap, and if the devices
in the array exceed 100G is size, an internal write-intent bitmap
will automatically be added unless some other option is explicitly
requested with the
.B \-\-bitmap
option or a different consistency policy is selected with the
.B \-\-consistency\-policy
option. In any case space for a bitmap will be reserved so that one
can be added later with
.BR "\-\-grow \-\-bitmap=internal" .
If the metadata type supports it (currently only 1.x and IMSM metadata),
space will be allocated to store a bad block list. This allows a modest
number of bad blocks to be recorded, allowing the drive to remain in
service while only partially functional.
When creating an array within a
.B CONTAINER
.I mdadm
can be given either the list of devices to use, or simply the name of
the container. The former case gives control over which devices in
the container will be used for the array. The latter case allows
.I mdadm
to automatically choose which devices to use based on how much spare
space is available.
The General Management options that are valid with
.B \-\-create
are:
.TP
.B \-\-run
insist on running the array even if some devices look like they might
be in use.
.TP
.B \-\-readonly
start the array in readonly mode.
.SH MANAGE MODE
.HP 12
Usage:
.B mdadm
.I device
.I options... devices...
.PP
This usage will allow individual devices in an array to be failed,
removed or added. It is possible to perform multiple operations with
on command. For example:
.br
.B " mdadm /dev/md0 \-f /dev/hda1 \-r /dev/hda1 \-a /dev/hda1"
.br
will firstly mark
.B /dev/hda1
as faulty in
.B /dev/md0
and will then remove it from the array and finally add it back
in as a spare. However only one md array can be affected by a single
command.
When a device is added to an active array, mdadm checks to see if it
has metadata on it which suggests that it was recently a member of the
array. If it does, it tries to "re\-add" the device. If there have
been no changes since the device was removed, or if the array has a
write-intent bitmap which has recorded whatever changes there were,
then the device will immediately become a full member of the array and
those differences recorded in the bitmap will be resolved.
.SH MISC MODE
.HP 12
Usage:
.B mdadm
.I options ...
.I devices ...
.PP
MISC mode includes a number of distinct operations that
operate on distinct devices. The operations are:
.TP
.B \-\-query
The device is examined to see if it is
(1) an active md array, or
(2) a component of an md array.
The information discovered is reported.
.TP
.B \-\-detail
The device should be an active md device.
.B mdadm
will display a detailed description of the array.
.B \-\-brief
or
.B \-\-scan
will cause the output to be less detailed and the format to be
suitable for inclusion in
.BR mdadm.conf .
The exit status of
.I mdadm
will normally be 0 unless
.I mdadm
failed to get useful information about the device(s); however, if the
.B \-\-test
option is given, then the exit status will be:
.RS
.TP
0
The array is functioning normally.
.TP
1
The array has at least one failed device.
.TP
2
The array has multiple failed devices such that it is unusable.
.TP
4
There was an error while trying to get information about the device.
.RE
.TP
.B \-\-detail\-platform
Print detail of the platform's RAID capabilities (firmware / hardware
topology). If the metadata is specified with
.B \-e
or
.B \-\-metadata=
then the return status will be:
.RS
.TP
0
metadata successfully enumerated its platform components on this system
.TP
1
metadata is platform independent
.TP
2
metadata failed to find its platform components on this system
.RE
.TP
.B \-\-update\-subarray=
If the device is a container and the argument to \-\-update\-subarray
specifies a subarray in the container, then attempt to update the given
superblock field in the subarray. Similar to updating an array in
"assemble" mode, the field to update is selected by
.B \-U
or
.B \-\-update=
option. The supported options are
.BR name ,
.B ppl
and
.BR no\-ppl .
The
.B name
option updates the subarray name in the metadata, it may not affect the
device node name or the device node symlink until the subarray is
re\-assembled. If updating
.B name
would change the UUID of an active subarray this operation is blocked,
and the command will end in an error.
The
.B ppl
and
.B no\-ppl
options enable and disable PPL in the metadata. Currently supported only for
IMSM subarrays.
.TP
.B \-\-examine
The device should be a component of an md array.
.I mdadm
will read the md superblock of the device and display the contents.
If
.B \-\-brief
or
.B \-\-scan
is given, then multiple devices that are components of the one array
are grouped together and reported in a single entry suitable
for inclusion in
.BR mdadm.conf .
Having
.B \-\-scan
without listing any devices will cause all devices listed in the
config file to be examined.
.TP
.BI \-\-dump= directory
If the device contains RAID metadata, a file will be created in the
.I directory
and the metadata will be written to it. The file will be the same
size as the device and have the metadata written in the file at the
same locate that it exists in the device. However the file will be "sparse" so
that only those blocks containing metadata will be allocated. The
total space used will be small.
The file name used in the
.I directory
will be the base name of the device. Further if any links appear in
.I /dev/disk/by-id
which point to the device, then hard links to the file will be created
in
.I directory
based on these
.I by-id
names.
Multiple devices can be listed and their metadata will all be stored
in the one directory.
.TP
.BI \-\-restore= directory
This is the reverse of
.BR \-\-dump .
.I mdadm
will locate a file in the directory that has a name appropriate for
the given device and will restore metadata from it. Names that match
.I /dev/disk/by-id
names are preferred, however if two of those refer to different files,
.I mdadm
will not choose between them but will abort the operation.
If a file name is given instead of a
.I directory
then
.I mdadm
will restore from that file to a single device, always provided the
size of the file matches that of the device, and the file contains
valid metadata.
.TP
.B \-\-stop
The devices should be active md arrays which will be deactivated, as
long as they are not currently in use.
.TP
.B \-\-run
This will fully activate a partially assembled md array.
.TP
.B \-\-readonly
This will mark an active array as read-only, providing that it is
not currently being used.
.TP
.B \-\-readwrite
This will change a
.B readonly
array back to being read/write.
.TP
.B \-\-scan
For all operations except
.BR \-\-examine ,
.B \-\-scan
will cause the operation to be applied to all arrays listed in
.BR /proc/mdstat .
For
.BR \-\-examine,
.B \-\-scan
causes all devices listed in the config file to be examined.
.TP
.BR \-b ", " \-\-brief
Be less verbose. This is used with
.B \-\-detail
and
.BR \-\-examine .
Using
.B \-\-brief
with
.B \-\-verbose
gives an intermediate level of verbosity.
.SH MONITOR MODE
.HP 12
Usage:
.B mdadm \-\-monitor
.I options... devices...
.PP
This usage causes
.I mdadm
to periodically poll a number of md arrays and to report on any events
noticed.
.I mdadm
will never exit once it decides that there are arrays to be checked,
so it should normally be run in the background.
As well as reporting events,
.I mdadm
may move a spare drive from one array to another if they are in the
same
.B spare-group
or
.B domain
and if the destination array has a failed drive but no spares.
If any devices are listed on the command line,
.I mdadm
will only monitor those devices. Otherwise all arrays listed in the
configuration file will be monitored. Further, if
.B \-\-scan
is given, then any other md devices that appear in
.B /proc/mdstat
will also be monitored.
The result of monitoring the arrays is the generation of events.
These events are passed to a separate program (if specified) and may
be mailed to a given E-mail address.
When passing events to a program, the program is run once for each event,
and is given 2 or 3 command-line arguments: the first is the
name of the event (see below), the second is the name of the
md device which is affected, and the third is the name of a related
device if relevant (such as a component device that has failed).
If
.B \-\-scan
is given, then a program or an E-mail address must be specified on the
command line or in the config file. If neither are available, then
.I mdadm
will not monitor anything.
Without
.B \-\-scan,
.I mdadm
will continue monitoring as long as something was found to monitor. If
no program or email is given, then each event is reported to
.BR stdout .
The different events are:
.RS 4
.TP
.B DeviceDisappeared
An md array which previously was configured appears to no longer be
configured. (syslog priority: Critical)
If
.I mdadm
was told to monitor an array which is RAID0 or Linear, then it will
report
.B DeviceDisappeared
with the extra information
.BR Wrong-Level .
This is because RAID0 and Linear do not support the device-failed,
hot-spare and resync operations which are monitored.
.TP
.B RebuildStarted
An md array started reconstruction (e.g. recovery, resync, reshape,
check, repair). (syslog priority: Warning)
.TP
.BI Rebuild NN
Where
.I NN
is a two-digit number (ie. 05, 48). This indicates that rebuild
has passed that many percent of the total. The events are generated
with fixed increment since 0. Increment size may be specified with
a commandline option (default is 20). (syslog priority: Warning)
.TP
.B RebuildFinished
An md array that was rebuilding, isn't any more, either because it
finished normally or was aborted. (syslog priority: Warning)
.TP
.B Fail
An active component device of an array has been marked as
faulty. (syslog priority: Critical)
.TP
.B FailSpare
A spare component device which was being rebuilt to replace a faulty
device has failed. (syslog priority: Critical)
.TP
.B SpareActive
A spare component device which was being rebuilt to replace a faulty
device has been successfully rebuilt and has been made active.
(syslog priority: Info)
.TP
.B NewArray
A new md array has been detected in the
.B /proc/mdstat
file. (syslog priority: Info)
.TP
.B DegradedArray
A newly noticed array appears to be degraded. This message is not
generated when
.I mdadm
notices a drive failure which causes degradation, but only when
.I mdadm
notices that an array is degraded when it first sees the array.
(syslog priority: Critical)
.TP
.B MoveSpare
A spare drive has been moved from one array in a
.B spare-group
or
.B domain
to another to allow a failed drive to be replaced.
(syslog priority: Info)
.TP
.B SparesMissing
If
.I mdadm
has been told, via the config file, that an array should have a certain
number of spare devices, and
.I mdadm
detects that it has fewer than this number when it first sees the
array, it will report a
.B SparesMissing
message.
(syslog priority: Warning)
.TP
.B TestMessage
An array was found at startup, and the
.B \-\-test
flag was given.
(syslog priority: Info)
.RE
Only
.B Fail,
.B FailSpare,
.B DegradedArray,
.B SparesMissing
and
.B TestMessage
cause Email to be sent. All events cause the program to be run.
The program is run with two or three arguments: the event
name, the array device and possibly a second device.
Each event has an associated array device (e.g.
.BR /dev/md1 )
and possibly a second device. For
.BR Fail ,
.BR FailSpare ,
and
.B SpareActive
the second device is the relevant component device.
For
.B MoveSpare
the second device is the array that the spare was moved from.
For
.I mdadm
to move spares from one array to another, the different arrays need to
be labeled with the same
.B spare-group
or the spares must be allowed to migrate through matching POLICY domains
in the configuration file. The
.B spare-group
name can be any string; it is only necessary that different spare
groups use different names.
When
.I mdadm
detects that an array in a spare group has fewer active
devices than necessary for the complete array, and has no spare
devices, it will look for another array in the same spare group that
has a full complement of working drive and a spare. It will then
attempt to remove the spare from the second drive and add it to the
first.
If the removal succeeds but the adding fails, then it is added back to
the original array.
If the spare group for a degraded array is not defined,
.I mdadm
will look at the rules of spare migration specified by POLICY lines in
.B mdadm.conf
and then follow similar steps as above if a matching spare is found.
.SH GROW MODE
The GROW mode is used for changing the size or shape of an active
array.
For this to work, the kernel must support the necessary change.
Various types of growth are being added during 2.6 development.
Currently the supported changes include
.IP \(bu 4
change the "size" attribute for RAID1, RAID4, RAID5 and RAID6.
.IP \(bu 4
increase or decrease the "raid\-devices" attribute of RAID0, RAID1, RAID4,
RAID5, and RAID6.
.IP \(bu 4
change the chunk-size and layout of RAID0, RAID4, RAID5, RAID6 and RAID10.
.IP \(bu 4
convert between RAID1 and RAID5, between RAID5 and RAID6, between
RAID0, RAID4, and RAID5, and between RAID0 and RAID10 (in the near-2 mode).
.IP \(bu 4
add a write-intent bitmap to any array which supports these bitmaps, or
remove a write-intent bitmap from such an array.
.IP \(bu 4
change the array's consistency policy.
.PP
Using GROW on containers is currently supported only for Intel's IMSM
container format. The number of devices in a container can be
increased - which affects all arrays in the container - or an array
in a container can be converted between levels where those levels are
supported by the container, and the conversion is on of those listed
above. Resizing arrays in an IMSM container with
.B "--grow --size"
is not yet supported.
.PP
Notes:
.IP \(bu 4
Intel's native checkpointing doesn't use
.B --backup-file
option and it is transparent for assembly feature.
.IP \(bu 4
Roaming between Windows(R) and Linux systems for IMSM metadata is not
supported during grow process.
.SS SIZE CHANGES
Normally when an array is built the "size" is taken from the smallest
of the drives. If all the small drives in an arrays are, one at a
time, removed and replaced with larger drives, then you could have an
array of large drives with only a small amount used. In this
situation, changing the "size" with "GROW" mode will allow the extra
space to start being used. If the size is increased in this way, a
"resync" process will start to make sure the new parts of the array
are synchronised.
Note that when an array changes size, any filesystem that may be
stored in the array will not automatically grow or shrink to use or
vacate the space. The
filesystem will need to be explicitly told to use the extra space
after growing, or to reduce its size
.B prior
to shrinking the array.
Also the size of an array cannot be changed while it has an active
bitmap. If an array has a bitmap, it must be removed before the size
can be changed. Once the change is complete a new bitmap can be created.
.PP
Note:
.B "--grow --size"
is not yet supported for external file bitmap.
.SS RAID\-DEVICES CHANGES
A RAID1 array can work with any number of devices from 1 upwards
(though 1 is not very useful). There may be times which you want to
increase or decrease the number of active devices. Note that this is
different to hot-add or hot-remove which changes the number of
inactive devices.
When reducing the number of devices in a RAID1 array, the slots which
are to be removed from the array must already be vacant. That is, the
devices which were in those slots must be failed and removed.
When the number of devices is increased, any hot spares that are
present will be activated immediately.
Changing the number of active devices in a RAID5 or RAID6 is much more
effort. Every block in the array will need to be read and written
back to a new location. From 2.6.17, the Linux Kernel is able to
increase the number of devices in a RAID5 safely, including restarting
an interrupted "reshape". From 2.6.31, the Linux Kernel is able to
increase or decrease the number of devices in a RAID5 or RAID6.
From 2.6.35, the Linux Kernel is able to convert a RAID0 in to a RAID4
or RAID5.
.I mdadm
uses this functionality and the ability to add
devices to a RAID4 to allow devices to be added to a RAID0. When
requested to do this,
.I mdadm
will convert the RAID0 to a RAID4, add the necessary disks and make
the reshape happen, and then convert the RAID4 back to RAID0.
When decreasing the number of devices, the size of the array will also
decrease. If there was data in the array, it could get destroyed and
this is not reversible, so you should firstly shrink the filesystem on
the array to fit within the new size. To help prevent accidents,
.I mdadm
requires that the size of the array be decreased first with
.BR "mdadm --grow --array-size" .
This is a reversible change which simply makes the end of the array
inaccessible. The integrity of any data can then be checked before
the non-reversible reduction in the number of devices is request.
When relocating the first few stripes on a RAID5 or RAID6, it is not
possible to keep the data on disk completely consistent and
crash-proof. To provide the required safety, mdadm disables writes to
the array while this "critical section" is reshaped, and takes a
backup of the data that is in that section. For grows, this backup may be
stored in any spare devices that the array has, however it can also be
stored in a separate file specified with the
.B \-\-backup\-file
option, and is required to be specified for shrinks, RAID level
changes and layout changes. If this option is used, and the system
does crash during the critical period, the same file must be passed to
.B \-\-assemble
to restore the backup and reassemble the array. When shrinking rather
than growing the array, the reshape is done from the end towards the
beginning, so the "critical section" is at the end of the reshape.
.SS LEVEL CHANGES
Changing the RAID level of any array happens instantaneously. However
in the RAID5 to RAID6 case this requires a non-standard layout of the
RAID6 data, and in the RAID6 to RAID5 case that non-standard layout is
required before the change can be accomplished. So while the level
change is instant, the accompanying layout change can take quite a
long time. A
.B \-\-backup\-file
is required. If the array is not simultaneously being grown or
shrunk, so that the array size will remain the same - for example,
reshaping a 3-drive RAID5 into a 4-drive RAID6 - the backup file will
be used not just for a "cricital section" but throughout the reshape
operation, as described below under LAYOUT CHANGES.
.SS CHUNK-SIZE AND LAYOUT CHANGES
Changing the chunk-size of layout without also changing the number of
devices as the same time will involve re-writing all blocks in-place.
To ensure against data loss in the case of a crash, a
.B --backup-file
must be provided for these changes. Small sections of the array will
be copied to the backup file while they are being rearranged. This
means that all the data is copied twice, once to the backup and once
to the new layout on the array, so this type of reshape will go very
slowly.
If the reshape is interrupted for any reason, this backup file must be
made available to
.B "mdadm --assemble"
so the array can be reassembled. Consequently the file cannot be
stored on the device being reshaped.
.SS BITMAP CHANGES
A write-intent bitmap can be added to, or removed from, an active
array. Either internal bitmaps, or bitmaps stored in a separate file,
can be added. Note that if you add a bitmap stored in a file which is
in a filesystem that is on the RAID array being affected, the system
will deadlock. The bitmap must be on a separate filesystem.
.SS CONSISTENCY POLICY CHANGES
The consistency policy of an active array can be changed by using the
.B \-\-consistency\-policy
option in Grow mode. Currently this works only for the
.B ppl
and
.B resync
policies and allows to enable or disable the RAID5 Partial Parity Log (PPL).
.SH INCREMENTAL MODE
.HP 12
Usage:
.B mdadm \-\-incremental
.RB [ \-\-run ]
.RB [ \-\-quiet ]
.I component-device
.RI [ optional-aliases-for-device ]
.HP 12
Usage:
.B mdadm \-\-incremental \-\-fail
.I component-device
.HP 12
Usage:
.B mdadm \-\-incremental \-\-rebuild\-map
.HP 12
Usage:
.B mdadm \-\-incremental \-\-run \-\-scan
.PP
This mode is designed to be used in conjunction with a device
discovery system. As devices are found in a system, they can be
passed to
.B "mdadm \-\-incremental"
to be conditionally added to an appropriate array.
Conversely, it can also be used with the
.B \-\-fail
flag to do just the opposite and find whatever array a particular device
is part of and remove the device from that array.
If the device passed is a
.B CONTAINER
device created by a previous call to
.IR mdadm ,
then rather than trying to add that device to an array, all the arrays
described by the metadata of the container will be started.
.I mdadm
performs a number of tests to determine if the device is part of an
array, and which array it should be part of. If an appropriate array
is found, or can be created,
.I mdadm
adds the device to the array and conditionally starts the array.
Note that
.I mdadm
will normally only add devices to an array which were previously working
(active or spare) parts of that array. The support for automatic
inclusion of a new drive as a spare in some array requires
a configuration through POLICY in config file.
The tests that
.I mdadm
makes are as follow:
.IP +
Is the device permitted by
.BR mdadm.conf ?
That is, is it listed in a
.B DEVICES
line in that file. If
.B DEVICES
is absent then the default it to allow any device. Similarly if
.B DEVICES
contains the special word
.B partitions
then any device is allowed. Otherwise the device name given to
.IR mdadm ,
or one of the aliases given, or an alias found in the filesystem,
must match one of the names or patterns in a
.B DEVICES
line.
This is the only context where the aliases are used. They are
usually provided by a
.I udev
rules mentioning
.BR $env{DEVLINKS} .
.IP +
Does the device have a valid md superblock? If a specific metadata
version is requested with
.B \-\-metadata
or
.B \-e
then only that style of metadata is accepted, otherwise
.I mdadm
finds any known version of metadata. If no
.I md
metadata is found, the device may be still added to an array
as a spare if POLICY allows.
.ig
.IP +
Does the metadata match an expected array?
The metadata can match in two ways. Either there is an array listed
in
.B mdadm.conf
which identifies the array (either by UUID, by name, by device list,
or by minor-number), or the array was created with a
.B homehost
specified and that
.B homehost
matches the one in
.B mdadm.conf
or on the command line.
If
.I mdadm
is not able to positively identify the array as belonging to the
current host, the device will be rejected.
..
.PP
.I mdadm
keeps a list of arrays that it has partially assembled in
.BR {MAP_PATH} .
If no array exists which matches
the metadata on the new device,
.I mdadm
must choose a device name and unit number. It does this based on any
name given in
.B mdadm.conf
or any name information stored in the metadata. If this name
suggests a unit number, that number will be used, otherwise a free
unit number will be chosen. Normally
.I mdadm
will prefer to create a partitionable array, however if the
.B CREATE
line in
.B mdadm.conf
suggests that a non-partitionable array is preferred, that will be
honoured.
If the array is not found in the config file and its metadata does not
identify it as belonging to the "homehost", then
.I mdadm
will choose a name for the array which is certain not to conflict with
any array which does belong to this host. It does this be adding an
underscore and a small number to the name preferred by the metadata.
Once an appropriate array is found or created and the device is added,
.I mdadm
must decide if the array is ready to be started. It will
normally compare the number of available (non-spare) devices to the
number of devices that the metadata suggests need to be active. If
there are at least that many, the array will be started. This means
that if any devices are missing the array will not be restarted.
As an alternative,
.B \-\-run
may be passed to
.I mdadm
in which case the array will be run as soon as there are enough
devices present for the data to be accessible. For a RAID1, that
means one device will start the array. For a clean RAID5, the array
will be started as soon as all but one drive is present.
Note that neither of these approaches is really ideal. If it can
be known that all device discovery has completed, then
.br
.B " mdadm \-IRs"
.br
can be run which will try to start all arrays that are being
incrementally assembled. They are started in "read-auto" mode in
which they are read-only until the first write request. This means
that no metadata updates are made and no attempt at resync or recovery
happens. Further devices that are found before the first write can
still be added safely.
.SH ENVIRONMENT
This section describes environment variables that affect how mdadm
operates.
.TP
.B MDADM_NO_MDMON
Setting this value to 1 will prevent mdadm from automatically launching
mdmon. This variable is intended primarily for debugging mdadm/mdmon.
.TP
.B MDADM_NO_UDEV
Normally,
.I mdadm
does not create any device nodes in /dev, but leaves that task to
.IR udev .
If
.I udev
appears not to be configured, or if this environment variable is set
to '1', the
.I mdadm
will create and devices that are needed.
.TP
.B MDADM_NO_SYSTEMCTL
If
.I mdadm
detects that
.I systemd
is in use it will normally request
.I systemd
to start various background tasks (particularly
.IR mdmon )
rather than forking and running them in the background. This can be
suppressed by setting
.BR MDADM_NO_SYSTEMCTL=1 .
.TP
.B IMSM_NO_PLATFORM
A key value of IMSM metadata is that it allows interoperability with
boot ROMs on Intel platforms, and with other major operating systems.
Consequently,
.I mdadm
will only allow an IMSM array to be created or modified if detects
that it is running on an Intel platform which supports IMSM, and
supports the particular configuration of IMSM that is being requested
(some functionality requires newer OROM support).
These checks can be suppressed by setting IMSM_NO_PLATFORM=1 in the
environment. This can be useful for testing or for disaster
recovery. You should be aware that interoperability may be
compromised by setting this value.
.TP
.B MDADM_GROW_ALLOW_OLD
If an array is stopped while it is performing a reshape and that
reshape was making use of a backup file, then when the array is
re-assembled
.I mdadm
will sometimes complain that the backup file is too old. If this
happens and you are certain it is the right backup file, you can
over-ride this check by setting
.B MDADM_GROW_ALLOW_OLD=1
in the environment.
.TP
.B MDADM_CONF_AUTO
Any string given in this variable is added to the start of the
.B AUTO
line in the config file, or treated as the whole
.B AUTO
line if none is given. It can be used to disable certain metadata
types when
.I mdadm
is called from a boot script. For example
.br
.B " export MDADM_CONF_AUTO='-ddf -imsm'
.br
will make sure that
.I mdadm
does not automatically assemble any DDF or
IMSM arrays that are found. This can be useful on systems configured
to manage such arrays with
.BR dmraid .
.SH EXAMPLES
.B " mdadm \-\-query /dev/name-of-device"
.br
This will find out if a given device is a RAID array, or is part of
one, and will provide brief information about the device.
.B " mdadm \-\-assemble \-\-scan"
.br
This will assemble and start all arrays listed in the standard config
file. This command will typically go in a system startup file.
.B " mdadm \-\-stop \-\-scan"
.br
This will shut down all arrays that can be shut down (i.e. are not
currently in use). This will typically go in a system shutdown script.
.B " mdadm \-\-follow \-\-scan \-\-delay=120"
.br
If (and only if) there is an Email address or program given in the
standard config file, then
monitor the status of all arrays listed in that file by
polling them ever 2 minutes.
.B " mdadm \-\-create /dev/md0 \-\-level=1 \-\-raid\-devices=2 /dev/hd[ac]1"
.br
Create /dev/md0 as a RAID1 array consisting of /dev/hda1 and /dev/hdc1.
.br
.B " echo 'DEVICE /dev/hd*[0\-9] /dev/sd*[0\-9]' > mdadm.conf"
.br
.B " mdadm \-\-detail \-\-scan >> mdadm.conf"
.br
This will create a prototype config file that describes currently
active arrays that are known to be made from partitions of IDE or SCSI drives.
This file should be reviewed before being used as it may
contain unwanted detail.
.B " echo 'DEVICE /dev/hd[a\-z] /dev/sd*[a\-z]' > mdadm.conf"
.br
.B " mdadm \-\-examine \-\-scan \-\-config=mdadm.conf >> mdadm.conf"
.br
This will find arrays which could be assembled from existing IDE and
SCSI whole drives (not partitions), and store the information in the
format of a config file.
This file is very likely to contain unwanted detail, particularly
the
.B devices=
entries. It should be reviewed and edited before being used as an
actual config file.
.B " mdadm \-\-examine \-\-brief \-\-scan \-\-config=partitions"
.br
.B " mdadm \-Ebsc partitions"
.br
Create a list of devices by reading
.BR /proc/partitions ,
scan these for RAID superblocks, and printout a brief listing of all
that were found.
.B " mdadm \-Ac partitions \-m 0 /dev/md0"
.br
Scan all partitions and devices listed in
.BR /proc/partitions
and assemble
.B /dev/md0
out of all such devices with a RAID superblock with a minor number of 0.
.B " mdadm \-\-monitor \-\-scan \-\-daemonise > /run/mdadm/mon.pid"
.br
If config file contains a mail address or alert program, run mdadm in
the background in monitor mode monitoring all md devices. Also write
pid of mdadm daemon to
.BR /run/mdadm/mon.pid .
.B " mdadm \-Iq /dev/somedevice"
.br
Try to incorporate newly discovered device into some array as
appropriate.
.B " mdadm \-\-incremental \-\-rebuild\-map \-\-run \-\-scan"
.br
Rebuild the array map from any current arrays, and then start any that
can be started.
.B " mdadm /dev/md4 --fail detached --remove detached"
.br
Any devices which are components of /dev/md4 will be marked as faulty
and then remove from the array.
.B " mdadm --grow /dev/md4 --level=6 --backup-file=/root/backup-md4"
.br
The array
.B /dev/md4
which is currently a RAID5 array will be converted to RAID6. There
should normally already be a spare drive attached to the array as a
RAID6 needs one more drive than a matching RAID5.
.B " mdadm --create /dev/md/ddf --metadata=ddf --raid-disks 6 /dev/sd[a-f]"
.br
Create a DDF array over 6 devices.
.B " mdadm --create /dev/md/home -n3 -l5 -z 30000000 /dev/md/ddf"
.br
Create a RAID5 array over any 3 devices in the given DDF set. Use
only 30 gigabytes of each device.
.B " mdadm -A /dev/md/ddf1 /dev/sd[a-f]"
.br
Assemble a pre-exist ddf array.
.B " mdadm -I /dev/md/ddf1"
.br
Assemble all arrays contained in the ddf array, assigning names as
appropriate.
.B " mdadm \-\-create \-\-help"
.br
Provide help about the Create mode.
.B " mdadm \-\-config \-\-help"
.br
Provide help about the format of the config file.
.B " mdadm \-\-help"
.br
Provide general help.
.SH FILES
.SS /proc/mdstat
If you're using the
.B /proc
filesystem,
.B /proc/mdstat
lists all active md devices with information about them.
.I mdadm
uses this to find arrays when
.B \-\-scan
is given in Misc mode, and to monitor array reconstruction
on Monitor mode.
.SS /etc/mdadm.conf
The config file lists which devices may be scanned to see if
they contain MD super block, and gives identifying information
(e.g. UUID) about known MD arrays. See
.BR mdadm.conf (5)
for more details.
.SS /etc/mdadm.conf.d
A directory containing configuration files which are read in lexical
order.
.SS {MAP_PATH}
When
.B \-\-incremental
mode is used, this file gets a list of arrays currently being created.
.SH DEVICE NAMES
.I mdadm
understand two sorts of names for array devices.
The first is the so-called 'standard' format name, which matches the
names used by the kernel and which appear in
.IR /proc/mdstat .
The second sort can be freely chosen, but must reside in
.IR /dev/md/ .
When giving a device name to
.I mdadm
to create or assemble an array, either full path name such as
.I /dev/md0
or
.I /dev/md/home
can be given, or just the suffix of the second sort of name, such as
.I home
can be given.
When
.I mdadm
chooses device names during auto-assembly or incremental assembly, it
will sometimes add a small sequence number to the end of the name to
avoid conflicted between multiple arrays that have the same name. If
.I mdadm
can reasonably determine that the array really is meant for this host,
either by a hostname in the metadata, or by the presence of the array
in
.BR mdadm.conf ,
then it will leave off the suffix if possible.
Also if the homehost is specified as
.B <ignore>
.I mdadm
will only use a suffix if a different array of the same name already
exists or is listed in the config file.
The standard names for non-partitioned arrays (the only sort of md
array available in 2.4 and earlier) are of the form
.IP
.RB /dev/md NN
.PP
where NN is a number.
The standard names for partitionable arrays (as available from 2.6
onwards) are of the form:
.IP
.RB /dev/md_d NN
.PP
Partition numbers should be indicated by adding "pMM" to these, thus "/dev/md/d1p2".
.PP
From kernel version 2.6.28 the "non-partitioned array" can actually
be partitioned. So the "md_d\fBNN\fP"
names are no longer needed, and
partitions such as "/dev/md\fBNN\fPp\fBXX\fP"
are possible.
.PP
From kernel version 2.6.29 standard names can be non-numeric following
the form:
.IP
.RB /dev/md_ XXX
.PP
where
.B XXX
is any string. These names are supported by
.I mdadm
since version 3.3 provided they are enabled in
.IR mdadm.conf .
.SH NOTE
.I mdadm
was previously known as
.IR mdctl .
.SH SEE ALSO
For further information on mdadm usage, MD and the various levels of
RAID, see:
.IP
.B http://raid.wiki.kernel.org/
.PP
(based upon Jakob \(/Ostergaard's Software\-RAID.HOWTO)
.PP
The latest version of
.I mdadm
should always be available from
.IP
.B http://www.kernel.org/pub/linux/utils/raid/mdadm/
.PP
Related man pages:
.PP
.IR mdmon (8),
.IR mdadm.conf (5),
.IR md (4).
|