summaryrefslogtreecommitdiffstats
path: root/man/sd_bus_default.xml
diff options
context:
space:
mode:
authorLennart Poettering <lennart@poettering.net>2015-07-11 21:11:45 +0200
committerLennart Poettering <lennart@poettering.net>2015-07-11 21:11:45 +0200
commitb898f9bd7eb803521ee8e5d51fe2174967541f86 (patch)
tree384f536fd2f05419dd137a054655e0c1dc6f6a0c /man/sd_bus_default.xml
parentMerge pull request #551 from poettering/fopen-temporary-noerrno (diff)
downloadsystemd-b898f9bd7eb803521ee8e5d51fe2174967541f86.tar.xz
systemd-b898f9bd7eb803521ee8e5d51fe2174967541f86.zip
man: go further into details regarding life-cycle of default bus connection objects
This extends on PR #542.
Diffstat (limited to 'man/sd_bus_default.xml')
-rw-r--r--man/sd_bus_default.xml70
1 files changed, 48 insertions, 22 deletions
diff --git a/man/sd_bus_default.xml b/man/sd_bus_default.xml
index 782dfb5706..1cf2cb8f9a 100644
--- a/man/sd_bus_default.xml
+++ b/man/sd_bus_default.xml
@@ -111,9 +111,9 @@
<para><function>sd_bus_default()</function> acquires a bus
connection object to the user bus when invoked in user context, or
to the system bus otherwise. The connection object is associated
- to the calling thread. Each time the function is invoked from the
- same thread the same object is returned, but its reference count
- is increased by one, as long as at least one reference is
+ with the calling thread. Each time the function is invoked from
+ the same thread the same object is returned, but its reference
+ count is increased by one, as long as at least one reference is
kept. When the last reference to the connection is dropped (using
the
<citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>
@@ -121,10 +121,11 @@
not automatically terminated when the associated thread ends. It
is important to drop the last reference to the bus connection
explicitly before the thread ends or otherwise the connection will
- be leaked.</para>
+ be leaked. Also, queued but unread or unwritten messages keep the
+ bus referenced, see below.</para>
<para><function>sd_bus_default_user()</function> returns a user
- bus connection object associated to the calling thread.
+ bus connection object associated with the calling thread.
<function>sd_bus_default_system()</function> is similar, but
connects to the system bus. Note that
<function>sd_bus_default()</function> is identical to these two
@@ -193,38 +194,63 @@
</refsect1>
<refsect1>
- <title>Return Value</title>
-
- <para>On success, these calls return 0 or a positive
- integer. On failure, these calls return a negative
- errno-style error code.</para>
- </refsect1>
-
- <refsect1>
<title>Reference ownership</title>
<para>The functions <function>sd_bus_open()</function>,
<function>sd_bus_open_user()</function>,
<function>sd_bus_open_system()</function>,
<function>sd_bus_open_system_remote()</function>, and
<function>sd_bus_open_system_machine()</function> return a new
- object and the caller owns the sole reference. When not needed
- anymore, this reference should be destroyed with
+ connection object and the caller owns the sole reference. When not
+ needed anymore, this reference should be destroyed with
<citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>.
</para>
<para>The functions <function>sd_bus_default()</function>,
<function>sd_bus_default_user()</function> and
<function>sd_bus_default_system()</function> do not necessarily
- create a new object, but increase the connection reference by
- one. Use
+ create a new object, but increase the connection reference of an
+ existing connection object by one. Use
<citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>
to drop the reference.</para>
- <para>Queued messages also keep a reference to the bus. For this reason, just
- because no application is having a reference to the bus does not mean that
- the bus object will be destroyed. Until all the messages are sent, the bus object
- will stay alive. <function>sd_bus_flush</function> can be used to send all the
- queued messages so they drop their references.</para>
+ <para>Queued but unwritten/unread messages also keep a reference
+ to their bus connection object. For this reason, even if an
+ application dropped all references to a bus connection it might
+ not get destroyed right-away. Until all incoming queued
+ messages are read, and until all outgoing unwritten messages are
+ written, the bus object will stay
+ alive. <function>sd_bus_flush()</function> may be used to write
+ all outgoing queued messages so they drop their references. To
+ flush the unread incoming messages use
+ <function>sd_bus_close()</function>, which will also close the bus
+ connection. When using the default bus logic it is a good idea to
+ first invoke <function>sd_bus_flush()</function> followed by
+ <function>sd_bus_close()</function> when a thread or process
+ terminates, and thus its bus connection object should be
+ freed.</para>
+
+ <para>The life-cycle of the default bus connection should be the
+ responsibility of the code that creates/owns the thread the
+ default bus connection object is associated with. Library code
+ should neither call <function>sd_bus_flush()</function> nor
+ <function>sd_bus_close()</function> on default bus objects unless
+ it does so in its own private, self-allocated thread. Library code
+ should not use the default bus object in other threads unless it
+ is clear that the program using it will life-cycle the bus
+ connection object and flush and close it before exiting from the
+ thread. In libraries where it is not clear that the calling
+ program will life-cycle the bus connection object it is hence
+ recommended to use <function>sd_bus_open_system()</function>
+ instead of <function>sd_bus_default_system()</function> and
+ related calls.</para>
+ </refsect1>
+
+ <refsect1>
+ <title>Return Value</title>
+
+ <para>On success, these calls return 0 or a positive
+ integer. On failure, these calls return a negative
+ errno-style error code.</para>
</refsect1>
<refsect1>