diff options
author | Lennart Poettering <lennart@poettering.net> | 2015-07-11 21:11:45 +0200 |
---|---|---|
committer | Lennart Poettering <lennart@poettering.net> | 2015-07-11 21:11:45 +0200 |
commit | b898f9bd7eb803521ee8e5d51fe2174967541f86 (patch) | |
tree | 384f536fd2f05419dd137a054655e0c1dc6f6a0c /man/sd_bus_default.xml | |
parent | Merge pull request #551 from poettering/fopen-temporary-noerrno (diff) | |
download | systemd-b898f9bd7eb803521ee8e5d51fe2174967541f86.tar.xz systemd-b898f9bd7eb803521ee8e5d51fe2174967541f86.zip |
man: go further into details regarding life-cycle of default bus connection objects
This extends on PR #542.
Diffstat (limited to 'man/sd_bus_default.xml')
-rw-r--r-- | man/sd_bus_default.xml | 70 |
1 files changed, 48 insertions, 22 deletions
diff --git a/man/sd_bus_default.xml b/man/sd_bus_default.xml index 782dfb5706..1cf2cb8f9a 100644 --- a/man/sd_bus_default.xml +++ b/man/sd_bus_default.xml @@ -111,9 +111,9 @@ <para><function>sd_bus_default()</function> acquires a bus connection object to the user bus when invoked in user context, or to the system bus otherwise. The connection object is associated - to the calling thread. Each time the function is invoked from the - same thread the same object is returned, but its reference count - is increased by one, as long as at least one reference is + with the calling thread. Each time the function is invoked from + the same thread the same object is returned, but its reference + count is increased by one, as long as at least one reference is kept. When the last reference to the connection is dropped (using the <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry> @@ -121,10 +121,11 @@ not automatically terminated when the associated thread ends. It is important to drop the last reference to the bus connection explicitly before the thread ends or otherwise the connection will - be leaked.</para> + be leaked. Also, queued but unread or unwritten messages keep the + bus referenced, see below.</para> <para><function>sd_bus_default_user()</function> returns a user - bus connection object associated to the calling thread. + bus connection object associated with the calling thread. <function>sd_bus_default_system()</function> is similar, but connects to the system bus. Note that <function>sd_bus_default()</function> is identical to these two @@ -193,38 +194,63 @@ </refsect1> <refsect1> - <title>Return Value</title> - - <para>On success, these calls return 0 or a positive - integer. On failure, these calls return a negative - errno-style error code.</para> - </refsect1> - - <refsect1> <title>Reference ownership</title> <para>The functions <function>sd_bus_open()</function>, <function>sd_bus_open_user()</function>, <function>sd_bus_open_system()</function>, <function>sd_bus_open_system_remote()</function>, and <function>sd_bus_open_system_machine()</function> return a new - object and the caller owns the sole reference. When not needed - anymore, this reference should be destroyed with + connection object and the caller owns the sole reference. When not + needed anymore, this reference should be destroyed with <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>. </para> <para>The functions <function>sd_bus_default()</function>, <function>sd_bus_default_user()</function> and <function>sd_bus_default_system()</function> do not necessarily - create a new object, but increase the connection reference by - one. Use + create a new object, but increase the connection reference of an + existing connection object by one. Use <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry> to drop the reference.</para> - <para>Queued messages also keep a reference to the bus. For this reason, just - because no application is having a reference to the bus does not mean that - the bus object will be destroyed. Until all the messages are sent, the bus object - will stay alive. <function>sd_bus_flush</function> can be used to send all the - queued messages so they drop their references.</para> + <para>Queued but unwritten/unread messages also keep a reference + to their bus connection object. For this reason, even if an + application dropped all references to a bus connection it might + not get destroyed right-away. Until all incoming queued + messages are read, and until all outgoing unwritten messages are + written, the bus object will stay + alive. <function>sd_bus_flush()</function> may be used to write + all outgoing queued messages so they drop their references. To + flush the unread incoming messages use + <function>sd_bus_close()</function>, which will also close the bus + connection. When using the default bus logic it is a good idea to + first invoke <function>sd_bus_flush()</function> followed by + <function>sd_bus_close()</function> when a thread or process + terminates, and thus its bus connection object should be + freed.</para> + + <para>The life-cycle of the default bus connection should be the + responsibility of the code that creates/owns the thread the + default bus connection object is associated with. Library code + should neither call <function>sd_bus_flush()</function> nor + <function>sd_bus_close()</function> on default bus objects unless + it does so in its own private, self-allocated thread. Library code + should not use the default bus object in other threads unless it + is clear that the program using it will life-cycle the bus + connection object and flush and close it before exiting from the + thread. In libraries where it is not clear that the calling + program will life-cycle the bus connection object it is hence + recommended to use <function>sd_bus_open_system()</function> + instead of <function>sd_bus_default_system()</function> and + related calls.</para> + </refsect1> + + <refsect1> + <title>Return Value</title> + + <para>On success, these calls return 0 or a positive + integer. On failure, these calls return a negative + errno-style error code.</para> </refsect1> <refsect1> |